Foundation design software for AS 3600, ACI 318, CSA A23.3 and Eurocode 7
TensorNode has 15 foundation design modules for Australia and New Zealand, United States, Canada and Europe. Pad, strip, combined and eccentric footings, post footings, bored piers, piered beams, retaining and basement walls, earth pressure, ground slabs and tree effects.
Create a free account to use it
7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.
Codes and editions
The standards below are the ones the foundation design modules use, by region and with the edition each module implements. The count is the number of modules that use the standard.
| Region | Standard and edition | Modules | Used by |
|---|---|---|---|
| Australia and New Zealand | AS 3600:2018 | 8 | Basement Wall, Combined Footing, Eccentric Pad, Industrial Slab, Pad Foundation and 3 more |
| Australia and New Zealand | AS 2159:2009 | 4 | Bored Pier, Eccentric Pad, Pad Foundation, Tree Effects: Piers |
| Australia and New Zealand | AS 2870:2011 | 3 | Residential Slab, Tree Effects: Piers, Tree Effects: y_s |
| Australia and New Zealand | AS 4678:2002 | 3 | Earth Pressure, Retaining Wall, Sleeper Wall |
| United States | ACI CODE-318-25 | 10 | Basement Wall, Bored Pier, Combined Footing, Eccentric Pad, Industrial Slab and 5 more |
| United States | IBC 2018 | 4 | Bored Pier, Post Footing, Residential Slab, Sleeper Wall |
| United States | ACI 360R-10 | 1 | Industrial Slab |
| United States | ANSI/AISC 360-22 | 1 | Sleeper Wall |
| United States | ANSI/AWC NDS-2018 | 1 | Sleeper Wall |
| United States | ASCE/SEI 7-22 | 1 | Earth Pressure |
| United States | IRC 2018 | 1 | Residential Slab |
| Canada | CSA A23.3-19 | 10 | Basement Wall, Bored Pier, Combined Footing, Eccentric Pad, Industrial Slab and 5 more |
| Canada | NBC 2020 | 5 | Bored Pier, Earth Pressure, Post Footing, Residential Slab, Sleeper Wall |
| Canada | CSA A23.1-19 | 1 | Residential Slab |
| Canada | CSA O86-19 | 1 | Sleeper Wall |
| Canada | CSA S16-19 | 1 | Sleeper Wall |
| Europe | EN 1997-1:2004+A1:2013 | 12 | Basement Wall, Bored Pier, Combined Footing, Earth Pressure, Eccentric Pad and 7 more |
| Europe | EN 1992-1-1:2004+A1:2014 | 10 | Basement Wall, Bored Pier, Combined Footing, Eccentric Pad, Industrial Slab and 5 more |
| Europe | EN 1990:2002+A1:2005 | 7 | Bored Pier, Combined Footing, Eccentric Pad, Pad Foundation, Piered Beam and 2 more |
| Europe | Concrete Society TR34 | 1 | Industrial Slab |
| Europe | EN 1993-1-1:2005+A1:2014 | 1 | Sleeper Wall |
| Europe | EN 1995-1-1:2004+A2:2014 | 1 | Sleeper Wall |
What each module checks
Each name opens the page of that module, with what it checks, the standards it works to and the related modules.
Retaining walls and slabs
- Basement Wall
Basement wall - Earth Pressure
Lateral earth pressure by Rankine theory - Industrial Slab
Industrial slab-on-grade under a concentrated (wheel/post) load - Residential Slab
Stiffened-raft / waffle footing screening to AS 2870 - Retaining Wall
Generic cantilever retaining wall - Sleeper Wall
Sleeper wall - Tree Effects: y_s
Characteristic surface movement y_s and AS 2870 site classification, including the effect of nearby trees that dry...
Footings
- Bored Pier
Bored (CFA/cast-in-situ) pier: drilled hole, concrete cast in-situ. - Combined Footing
Combined footing supporting two columns - Eccentric Pad
Eccentrically-loaded pad footing - Pad Foundation
Factored loading with eccentricity, uplift, sliding and overturning; two-way reinforcement by mesh (SL/RL) or bar... - Piered Beam
Reinforced-concrete ground beam spanning between bored piers - Post Footing
Embedded post footing driven by lateral load, applied moment, load height, footing width/depth and soil φ/γ... - Strip Footing
Continuous strip footing under a wall line-load - Tree Effects: Piers
Bored pier through a tree-affected reactive (drying/swelling) zone
Report for every check
Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.
Try it
Create a free account to use the modules: 7 days of the Professional plan, no card. 2 of the 15 modules above are among the basic calculators of the Free plan, which you keep after the trial. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design.
Questions
Which codes do the foundation design modules cover?
The 15 modules work to AS 3600, ACI 318, CSA A23.3 and Eurocode 7. Editions: Australia and New Zealand: AS 3600:2018, AS 2159:2009, AS 4678:2002, AS 2870:2011; United States: ACI CODE-318-25, IBC 2018, ASCE/SEI 7-22, ANSI/AWC NDS-2018 and 2 more; Canada: CSA A23.3-19, NBC 2020, CSA O86-19, CSA S16-19 and 1 more; Europe: EN 1997-1:2004+A1:2013, EN 1992-1-1:2004+A1:2014, EN 1990:2002+A1:2005, EN 1993-1-1:2005+A1:2014 and 1 more. Pick the code system once and every module follows it.
Which regions are covered?
Australia and New Zealand, United States, Canada and Europe. 13 of the 15 modules work to all four code systems.
Can I try them without a card?
Yes. Create an account with your email and a password: you get 7 days of the Professional plan with no card. After that the account moves to the Free plan and nothing is charged automatically. 2 of these 15 modules are among the basic calculators of the Free plan.
Does TensorNode include the text of the standards?
Standards are cited by number and edition only. TensorNode does not reproduce the text of any standard; keep your own current copy.
Who checks the results?
TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design.
Create a free account to use it
7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.