TensorNodeOpen TensorNode
Home / Scope and limits

Scope and limits

What each module covers and what it does not. Read the limits of a module before relying on its results.

For every module and the FEA Tool

  • TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design.
  • Reports carry a statement to that effect and a code that confirms the report has not been changed since it was made.
  • Standards are cited by number and edition only. TensorNode does not reproduce the text of any standard; keep your own current copy.
  • The FEA Tool analyses the model you build. It does not check that a model suits the structure, the loads or the supports you intend; model checking is the engineer's work.
  • Results are given in the units shown (lengths in m, forces in kN, stresses in MPa unless the field says otherwise).

By module

Analysis

What it does. General single-span beam analysis: reactions, maximum bending moment and shear, and elastic deflection for a uniform and/or point load on a simply-supported, cantilever, propped-cantilever or fixed-end beam.

Standards.

    Limits.

    • Single span only: continuous beams, frames and moving loads need a matrix/continuous-beam analysis.
    • Deflection is the elastic value; long-term creep/shrinkage (concrete, timber) multipliers are applied separately.
    • The propped and fixed cases assume idealised full fixity; real end stiffness will differ.
    • This module sizes actions only: member capacity is checked in the relevant material module.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Dead & Live Loads

    What it does. Load takedown: builds the permanent (G) action from its components and the imposed (Q) action, applies the AS/NZS 1170.0 ULS and SLS combinations, and converts to a design line load over a tributary width.

    Standards.

    • AS/NZ: AS/NZS 1170.1:2002
    • US: ASCE/SEI 7-22
    • CA: NBC 2020
    • EU: EN 1990:2002+A1:2005

    Limits.

    • Pattern (alternate-span) live load, area-reduction factors (ψa) and concentrated imposed loads are not applied automatically.
    • Wind, earthquake, snow, thermal and liquid-pressure combinations are outside this gravity takedown.
    • Two-way load distribution and load sharing between members are not modelled: use the slab/analysis modules.
    • Dynamic/impact factors for plant, vehicles or crowds must be added where relevant.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Section Properties

    What it does. Section property calculator: looks up a hot-rolled library section (area, second moments, section/plastic moduli, radii of gyration, mass) or computes the properties of a custom rectangular, circular or I-shape from first principles.

    Standards.

    • AS/NZ: AS/NZS 3679.1

    Limits.

    • Built-up, tapered and asymmetric fabricated sections need a dedicated section analysis.
    • Torsional constant (J) and warping constant (I_w) are not reported here.
    • Net-section (holes) and effective-section (slender-element) properties are member-design checks.
    • Cold-formed section properties should come from the manufacturer.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Composite Member

    What it does. Simply-supported composite steel-and-concrete beam to AS 2327: a library steel section acting compositely with a profiled-deck slab (Bondek / Condek / KingFlor / RF / solid), with the effective flange width, the plastic composite moment capacity, the degree of

    Standards.

    • AS/NZ: AS 2327:2017
    • US: ANSI/AISC 360-22
    • CA: CSA S16-19
    • EU: EN 1994-1-1:2004, EN 1993-1-1:2005+A1:2014, EN 1990:2002+A1:2005

    Limits.

    • Continuous/cantilever composite beams (hogging regions, with the slab in tension and reinforcement-governed capacity) are not covered: sagging, simply-supported only.
    • The steel-PNA case uses a top-flange approximation; if the neutral axis falls in the web a full plastic analysis should confirm the capacity.
    • Construction-stage strength and deflection (steel section carrying the wet slab), long-term composite deflection, shrinkage and vibration are assessed separately.
    • Stud capacity, k_t and the minimum degree of shear connection should be confirmed against AS 2327 and the manufacturer’s deck data for the specific profile and stud layout.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Beam Shear

    What it does. Reinforced-concrete beam shear to AS 3600 §8.2: concrete contribution φVuc plus shear-reinforcement φVus (vertical stirrups), with the minimum-reinforcement and maximum-spacing detailing and the web-crushing limit.

    Standards.

    • AS/NZ: AS 3600:2018
    • US: ACI CODE-318-25
    • CA: CSA A23.3-19
    • EU: EN 1992-1-1:2004+A1:2014

    Limits.

    • The general (variable-angle / ε_x) method of §8.2.4.3 may give a higher capacity for lightly-loaded members or a lower angle: use it where the simplified result is marginal.
    • Shear near supports/point loads (within d_v) and the design for torsion (§8.3 combined V+T) are not covered here.
    • Members without the minimum stirrups, deep beams (use the Strut & Tie module) and prestressed sections need their specific provisions.
    • Bar cut-off, the shift rule and anchorage of the longitudinal steel are detailed separately.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Beam Torsion

    What it does. Reinforced-concrete beam torsion to AS 3600:2018 Cl.

    Standards.

    • AS/NZ: AS 3600:2018
    • US: ACI CODE-318-25
    • CA: CSA A23.3-19
    • EU: EN 1992-1-1:2004+A1:2014

    Limits.

    • Box and hollow sections, T and L beams (flange torsion rectangles), prestressed members and axial force are not covered.
    • Stirrup anchorage with 135 degree hooks, lap and splice of the longitudinal bars, bar cut-off and the torsion extent beyond the point required are detailed separately.
    • The flexural design (strength, crack control, deflection) is a separate module; the torsion longitudinal bars here are added to it.
    • Cl. 8.2.1.2 and 8.2.8 are applied to the solid-section equations only; Eq. 8.2.7.1(2) for box sections is not used.
    • The cross-references printed in AS 3600:2018 Cl. 8.2.1.2 (to Cl. 8.2.5.4) and 8.2.5.5 (to Cl. 8.2.9) contain slips; the working here follows the intended clauses 8.2.5.5, 8.2.7 and 8.2.8. Eq. 8.2.3.4(3) and Eq. 8.2.7.1(1) were reconstructed from the extracted text.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Column Biaxial

    What it does. RC column under axial load with biaxial bending to AS 3600 §10.6.3, the P-M interaction is built by strain compatibility about each axis, with reinforcement placed on all four faces (top/bottom bars resist X-axis bending, side bars resist Y-axis bending, both

    Standards.

    • AS/NZ: AS 3600:2018
    • US: ACI CODE-318-25
    • CA: CSA A23.3-19
    • EU: EN 1992-1-1:2004+A1:2014

    Limits.

    • Circular and heavily unsymmetric sections need the dedicated layout; this assumes a rectangular section with distributed bars.
    • Slenderness amplification (moment magnification) is not added here.
    • Confinement and high-strength-concrete ductility limits are not explicitly treated.
    • Shear and the tie/ligature design are separate checks.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Column Interaction

    What it does. Rectangular reinforced-concrete column to AS 3600 §10: squash load, full N-M interaction by strain compatibility, biaxial bending about both axes, capacity-point table and slenderness screen.

    Standards.

    • AS/NZ: AS 3600:2018
    • US: ACI CODE-318-25
    • CA: CSA A23.3-19
    • EU: EN 1992-1-1:2004+A1:2014

    Limits.

    • Biaxial capacities φMux/φMuy use the two-layer idealisation; for columns with significant side-face (intermediate) bars, model the actual bar layout for the minor-axis curve.
    • Creep enters through β_d (the sustained fraction of the axial load) in N_c; the storey magnifier δ_s of unbraced frames is not computed by this member module.
    • Confinement/ductility detailing (fitment spacing, §10.7), shear and the minimum/maximum reinforcement limits (§10.7.1) are checked separately.
    • Tension capacity of the section (net axial tension) is not part of this compression-interaction check.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Concrete Durability and Cover

    What it does. Durability and cover to reinforcement to AS 3600:2018 Section 4: exposure classification (Table 4.3, with the sulfate and saline soil tables 4.8.1 and 4.8.2), minimum f'c and curing (Table 4.4, with the abrasion and freezing and thawing limits of Table 4.6 and

    Standards.

    • AS/NZ: AS 3600:2018
    • US: ACI CODE-318-25
    • CA: CSA A23.1-19
    • EU: EN 1992-1-1:2004+A1:2014

    Limits.

    • Fire resistance cover, bar development and bond, crack control and structural strength are checked separately.
    • Class U (specific design), plain concrete (class A1 unless aggressive), spun and rolled members, embedded items (Cl. 4.10.3.6, 4.10.3.7), ducts, tendons and protective coatings are not covered; alkali aggregate reactivity (Cl. 4.2) is not assessed.
    • The tabulated cover for C2 at 40 MPa is blank in the extracted text and is treated as not available, and the Table 4.4 curing period for B1 follows the table layout of the code database (3 days): check both against the published standard.
    • Clause and table numbers follow the TensorNode code database text; paraphrased, not quoted.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Concrete Wall

    What it does. RC wall in compression by the AS 3600 §11.5.3 simplified method: the design axial capacity per metre from the wall thickness, the load eccentricity and the slenderness-derived additional eccentricity, with the minimum vertical reinforcement.

    Standards.

    • AS/NZ: AS 3600:2018
    • US: ACI CODE-318-25
    • CA: CSA A23.3-19
    • EU: EN 1992-1-1:2004+A1:2014

    Limits.

    • The simplified method is only valid within the §11.5.3 limits (e ≤ t_w/6 and the slenderness cap); outside these, use the column (§10) design.
    • In-plane shear (for shear walls), out-of-plane bending and combined actions need the full §11/§10 design.
    • Concentrated loads and openings require local checks (e.g. struts/lintels around openings).
    • Fire and durability cover requirements are separate.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Corbel / Bracket

    What it does. Reinforced-concrete corbel / bracket to AS 3600: shear-friction with the casting-interface condition (monolithic / roughened / smooth / against steel), main tension tie and closed ties from the vertical and horizontal actions, bearing and the maximum shear lim

    Standards.

    • AS/NZ: AS 3600:2018
    • US: ACI CODE-318-25
    • CA: CSA A23.3-19
    • EU: EN 1992-1-1:2004+A1:2014

    Limits.

    • The main tie must be anchored at the outer face (welded cross-bar or hooks) and fully developed into the column: anchorage detailing is critical for corbels and is checked separately.
    • μ values are representative shear-friction coefficients for the interface condition; where a cold joint roughness or a bonded/un-bonded interface differs, adjust μ to the project specification.
    • Very deep brackets (a_v/d > 1) act in flexure/shear like a cantilever and fall outside this corbel method: design as a cantilever to §8.
    • The supported-member restraint, dapped-end interaction and the column local effects below the corbel are designed separately.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Crack Control

    What it does. Crack control for RC beams/slabs by the AS 3600 §8.6.2.2 deemed-to-comply method: the serviceability steel stress is checked against the larger of the bar-diameter and bar-spacing limits (Tables 8.6.2.2(A) and (B), selected w'max), plus the minimum tensile rei

    Standards.

    • AS/NZ: AS 3600:2018
    • US: ACI CODE-318-25
    • CA: CSA A23.3-19
    • EU: EN 1992-1-1:2004+A1:2014

    Limits.

    • For exposure classifications requiring a crack-width calculation, the deemed-to-comply check may not suffice: a direct crack-width assessment is needed.
    • Restraint/shrinkage cracking (e.g. in walls and slabs) is governed by the §8.6.1/§9 minimum-reinforcement rules, not this flexural check alone.
    • The tabulated limits are taken at the next larger diameter or spacing row (no interpolation), which is conservative between rows.
    • Early-age thermal and long-term shrinkage effects enter only when they are selected under Effects in the crack width (DURARE model, CIRIA C766 restraint).
    • **Shear (ligature) reinforcement is NOT an input here**: AS 3600 §8.6 flexural crack control depends only on the tensile steel stress f_s and the tension-bar diameter/spacing. Diagonal (shear) crack control is a separate topic, satisfied by providing the minimum shear reinforcement required in §8.2.1.7 (checked in the Flexure/Piered Beam modules' ligature shear check), not by a crack-width calculation.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Deep Beam

    What it does. RC deep beam (span/depth < 2) by strut-and-tie to AS 3600 §7: a diagonal concrete strut carries the load to the supports and a bottom tie carries the tension; the strut, tie, node bearing and diagonal-compression limit are checked.

    Standards.

    • AS/NZ: AS 3600:2018
    • US: ACI CODE-318-25
    • CA: CSA A23.3-19
    • EU: EN 1992-1-1:2004+A1:2014

    Limits.

    • A simple single-panel truss is used; multi-panel or continuous deep beams need the full strut-and-tie model.
    • The tie anchorage check assumes the beam ends at the outer face of the bearing; a longer overhang, a U-bar or a mechanical anchor increases the available length.
    • Openings, indirect supports and concentrated loads off the truss lines change the model.
    • Serviceability crack widths are controlled by the bar stress and spacing limits of §12.7, not computed.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Development & Laps

    What it does. Reinforcement development and lap lengths to AS 3600 §13: basic tension development length Lsy.tb (with the bar-position, cover/confinement and concrete-strength factors), compression development, and tension/compression lap lengths.

    Standards.

    • AS/NZ: AS 3600:2018
    • US: ACI CODE-318-25
    • CA: CSA A23.3-19
    • EU: EN 1992-1-1:2004+A1:2014

    Limits.

    • This is a detailing reference (no pass/fail): the required anchorage at a specific location (support, cut-off, lap) and the bundled-bar and epoxy-coated provisions must be applied in context.
    • Stress development less than f_sy (partial anchorage) and staggered laps are not enumerated here.
    • Development in compression members and at beam-column joints can have additional confinement requirements (§13.1.5, seismic provisions where applicable).
    • Values assume normal-density concrete; lightweight concrete reduces bond and increases the lengths.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    FRP Flexural Strengthening

    What it does. Externally bonded FRP (carbon, glass or aramid; fabric or pre-cured laminate) on the soffit of an existing reinforced concrete beam or slab strip: ACI PRC-440.2-17 Chapter 10 with debonding, the initial strain at installation, the strengthening limit, service

    Standards.

    • US: ACI PRC-440.2-17, ACI CODE-318-19

    Limits.

    • Flexure only: shear strengthening, axial confinement, fire (Chapter 9.2.1) and deflection are separate checks.
    • Library FRP properties are typical published values for preliminary sizing; the design must use the guaranteed values (mean minus three standard deviations) of the product installed.
    • Rectangular section with one layer of tension steel; compression steel and T-beam flanges are not included.
    • Canadian (CSA S806-12 Clause 11) and European (fib Bulletin 90, TR55, CNR-DT 200) methods use other debonding and safety formats and are not offered here.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Flat Slab

    What it does. Flat slab (column-supported, no beams) by the Direct Design Method: the total static moment per panel, its negative/positive split, the column-strip and middle-strip distribution in both directions, and the top and bottom reinforcement (bar diameter and spacin

    Standards.

    • AS/NZ: AS 3600:2018
    • US: ACI CODE-318-25
    • CA: CSA A23.3-19
    • EU: EN 1992-1-1:2004+A1:2014

    Limits.

    • Punching (two-way) shear at the columns is the usual governing check and is performed in the Punching Shear module: it is not repeated here.
    • The DDM applies only within its geometric limits (span ratio ≤ 2, limited offsets); irregular layouts need an equivalent-frame or finite-element analysis.
    • Pattern live load, edge/corner-panel and unbalanced-moment transfer to columns, and slab openings are not covered by this summary.
    • Long-term deflection, crack control for exposure and the column-strip detailing (bar curtailment, integrity steel) are assessed separately.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Flexure Member

    What it does. Rectangular, T- and L-beam flexure to AS 3600: bar-by-bar reinforcement (number and size), with the section classified balanced / under- / over-reinforced, a tension-steel yielding check, minimum and maximum steel, optional compression steel (doubly-reinforced

    Standards.

    • AS/NZ: AS 3600:2018
    • US: ACI CODE-318-25
    • CA: CSA A23.3-19
    • EU: EN 1992-1-1:2004+A1:2014

    Limits.

    • Simply-supported UDL bending is assumed for M* and V*; continuous or point-loaded members require the actual bending/shear envelope.
    • Shear reinforcement (ligatures) is not detailed where φV_uc is exceeded: the shear check flags the need only.
    • Torsion, compression-steel contribution and fire design are not included.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    One-Way Slab

    What it does. One-way reinforced-concrete slab to AS 3600: user-input bar diameter and spacing for the bottom (sag), top (hog) and secondary layers, with factored and service loads; flexure, one-way shear, service deflection, minimum reinforcement and crack-control checks.

    Standards.

    • AS/NZ: AS 3600:2018
    • US: ACI CODE-318-25
    • CA: CSA A23.3-19
    • EU: EN 1992-1-1:2004+A1:2014

    Limits.

    • Continuous-slab moments here are coefficient-based: for unequal spans, pattern loading or cantilevers use the §6.10.2 coefficients or an analysis; the support hog reinforcement must match the actual negative moment.
    • Deflection uses a single effective inertia and the short-term service load: long-term (creep/shrinkage k_cs) multipliers and incremental (post-construction) deflection limits must be added for brittle finishes.
    • Punching/two-way action (where the slab is supported on columns) and concentrated loads are covered by the Punching Shear module, not here.
    • Fire and durability cover, and bar development/anchorage at supports, are confirmed separately.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Plain Concrete

    What it does. Plain (unreinforced) concrete member to AS 3600 §20, a rectangular member of width b, depth D and bearing length L set by the user.

    Standards.

    • AS/NZ: AS 3600:2018
    • US: ACI CODE-318-25
    • CA: CSA A23.3-19
    • EU: EN 1992-1-1:2004+A1:2014

    Limits.

    • Not for members requiring ductility or where flexural cracking would be unsafe: provide reinforcement instead.
    • Shrinkage and thermal cracking can negate the tensile capacity; control joints are needed.
    • Combined axial-plus-bending beyond the kern (net tension) is outside this simple check.
    • Fatigue, impact and seismic actions require reinforcement.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Punching Shear

    What it does. Two-way (punching) shear at a slab-column connection to AS 3600 §9.3: circular or rectangular column, interior/edge/corner case, unbalanced-moment transfer, and shear-reinforcement / integrity check.

    Standards.

    • AS/NZ: AS 3600:2018
    • US: ACI CODE-318-25
    • CA: CSA A23.3-19
    • EU: EN 1992-1-1:2004+A1:2014

    Limits.

    • The shear-reinforced ceiling φVu,max is an upper limit: the actual fitment/stud area and layout (spacing ≤ 0.5d_om, first set ≤ 0.5d_om from the face) must be designed to §9.3.4.
    • Openings adjacent to the column, slab steps and prestress effects on the perimeter are not modelled: reduce u where openings fall within the §9.3.3 zone.
    • Combined biaxial unbalanced moments and corner-column torsion are simplified to the governing direction; a detailed §9.3.4 treatment may be required.
    • Direct (one-way/beam) shear and flexure of the slab are checked separately.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Reinforcement Table

    What it does. Reinforcement quantity reference: bar area, number of bars per metre and steel area for a chosen bar diameter and spacing (or count over a width), with a quick area-per-metre lookup grid.

    Standards.

    • AS/NZ: AS 3600:2018
    • US: ACI CODE-318-25
    • CA: CSA A23.3-19, CSA G30.18
    • EU: EN 1992-1-1:2004+A1:2014, EN 10080

    Limits.

    • Mesh (SL/RL) areas and non-standard bar sizes are not tabulated here: use the design module’s mesh library where a fabric is specified.
    • No structural check is performed; quantities only.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Stair

    What it does. RC stair flight (waist slab): the dead load of the inclined waist and steps plus the live load, the span moment and shear, the flexural reinforcement and the span/depth serviceability check.

    Standards.

    • AS/NZ: AS 3600:2018
    • US: ACI CODE-318-25
    • CA: CSA A23.3-19
    • EU: EN 1992-1-1:2004+A1:2014

    Limits.

    • Landings, folded/scissor stairs and cantilever (spine-beam) stairs need their own models.
    • The support reactions into the landing slabs/beams and the landing design are separate.
    • Stairs supported on stringers or with open risers change the load path.
    • Vibration/comfort and crack control are separate serviceability checks.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Strut & Tie

    What it does. Strut-and-tie model for a concrete D-region / deep beam to AS 3600 §7: strut efficiency factor βs, diagonal-strut and bottom-tie capacities, node bearing, the diagonal-compression limit, and tie reinforcement (bar diameter and number).

    Standards.

    • AS/NZ: AS 3600:2018
    • US: ACI CODE-318-25
    • CA: CSA A23.3-19
    • EU: EN 1992-1-1:2004+A1:2014

    Limits.

    • The node check is the bearing stress at the support node, a CCT node with β_n = 0.8 (§7.4.2); the other node faces are not checked separately.
    • Serviceability crack control of the tie (bar spacing/stress) is reported as a deemed check only: confirm against §8.6 where crack width is critical.
    • Web bar stress for serviceability is taken as 250 MPa with s ≤ 300 mm (moderate degree of crack control, AS 3600 Table 12.7); use the strong degree (200 MPa, 200 mm) where cracks are visible or reflect through finishes.
    • The model assumes the bearing and reaction geometry given; eccentric or inclined reactions require a revised truss.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Two-Way Slab

    What it does. Two-way spanning slab supported on four edges: the Grashof load share between the short and long spans, the positive span moments (and support hogging if continuous), reinforcement each way and the span/depth deflection control.

    Standards.

    • AS/NZ: AS 3600:2018
    • US: ACI CODE-318-25
    • CA: CSA A23.3-19
    • EU: EN 1992-1-1:2004+A1:2014

    Limits.

    • The load-share method is an approximation: for irregular panels, large openings or unequal continuity use the §6.10 moment coefficients or a finite-element/yield-line analysis.
    • Punching at columns (for flat slabs) and edge/corner effects are separate.
    • Deflection is controlled by a span/depth rule; a direct calculation is needed where it governs.
    • One-way action applies for Ly/Lx beyond about 2: use the one-way slab module.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Drainage

    What it does. Pipe / drain capacity by the Manning equation: the full-bore velocity and flow capacity for a circular pipe at a given grade and roughness, with a self-cleansing-velocity check and an optional capacity-versus-demand check.

    Standards.

    • AS/NZ: AS/NZS 3500.3
    • US: IPC 2018, ASCE/SEI 7-22
    • CA: NPC 2020, NBC 2020
    • EU: EN 12056-3, EN 752

    Limits.

    • Part-full flow, surcharge, backwater and pipe-network routing are not modelled: full-bore capacity only.
    • Inlet capacity, pit/junction losses and the hydraulic grade line are separate checks.
    • Manning suits rough turbulent flow; for smooth pipes or pressure flow use Colebrook-White.
    • Minimum/maximum velocity, cover and grade requirements of AS/NZS 3500.3 must also be satisfied.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Rainfall Intensity (AEP)

    What it does. Design rainfall intensity expressed in the modern annual-exceedance-probability (AEP) frequency descriptor: converts the AEP to an equivalent ARI and returns the IFD intensity and optional peak flow.

    Standards.

    • AS/NZ: ARR 2019, AS/NZS 3500.3
    • US: NOAA Atlas 14, IPC 2018, ASCE/SEI 7-22
    • CA: NBC 2020, NPC 2020
    • EU: EN 12056-3, EN 752

    Limits.

    • For very frequent events (high AEP) the simple conversion and power-law scaling are approximate: read the BoM IFD directly.
    • Areal reduction, ARR temporal patterns, losses and climate-change factors are not applied.
    • Authoritative design rainfalls are the BoM IFD values for the site.
    • Large catchments require a routing model rather than the Rational Method.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Rainfall Intensity (ARI)

    What it does. Design rainfall intensity for a chosen average recurrence interval (ARI) and storm duration from the site IFD coefficients, with the equivalent AEP and an optional Rational-Method peak flow.

    Standards.

    • AS/NZ: AS/NZS 3500.3
    • US: NOAA Atlas 14, IPC 2018, ASCE/SEI 7-22
    • CA: NBC 2020, NPC 2020
    • EU: EN 12056-3, EN 752

    Limits.

    • This is a screening intensity: the authoritative values are the BoM IFD design rainfalls for the exact location.
    • Areal reduction, temporal patterns and losses (ARR 2019) are not applied; this gives a point intensity.
    • The Rational Method suits small catchments; larger catchments need a routed runoff model.
    • Climate-change rainfall uplift factors are not included.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Stormwater Detention

    What it does. On-site stormwater detention (OSD): the pre- and post-development peak flows, the required detention storage volume and the orifice size to throttle the outflow to the permitted site-discharge.

    Standards.

    • AS/NZ: AS/NZS 3500
    • EU: EN 752

    Limits.

    • A simplified (Rational) estimate: council typically requires a routed analysis (e.g. DRAINS/ILSAX) for approval.
    • The critical storm duration should be found by iterating durations; a single duration is used here.
    • Multiple outlets, high-early-discharge (HED) systems and infiltration/re-use are not modelled.
    • Water-quality (treatment) volumes and freeboard are separate requirements.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Earthquake Design Category

    What it does. Earthquake Design Category (EDC) determination to AS 1170.4 §2: from the hazard product kp·Z, the site sub-soil class, the structure height and the importance level, giving the required analysis method.

    Standards.

    • AS/NZ: AS 1170.4:2007
    • US: ASCE/SEI 7-22
    • CA: NBC 2020
    • EU: EN 1998-1:2004+A1:2013

    Limits.

    • This is a screening of the required analysis level only: it does not perform the earthquake analysis itself (use the Static Analysis module for EDC II).
    • IL1 structures need no earthquake design and are reported as EDC I; domestic structures use the housing provisions of Appendix A of AS 1170.4, not this table.
    • Structures with irregularity or special importance may require a higher analysis level than the category minimum.
    • Special structures (AS 1170.4 §1.1 exclusions) and non-building structures are outside this scope.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Static Analysis

    What it does. Equivalent static earthquake analysis to AS 1170.4: the spectral shape factor, the horizontal design coefficient, the base shear and its vertical distribution up the height of a regular building.

    Standards.

    • AS/NZ: AS 1170.4:2007
    • US: ASCE/SEI 7-22
    • CA: NBC 2020
    • EU: EN 1998-1:2004+A1:2013

    Limits.

    • Irregular, torsionally-sensitive or tall structures require a dynamic (modal/response-spectrum or time-history) analysis (§7).
    • C_h(T_1) was checked against the AS 1170.4-2007 Table 6.4 text: tabulated values are returned at the table periods; beyond 5 s the 5 s value is held and a dynamic analysis is advised.
    • Drift, P-Δ, torsion, accidental eccentricity and element actions are not evaluated here.
    • Soil-structure interaction, vertical earthquake and non-structural component actions are separate.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Steel Member in Fire

    What it does. Fire resistance of a steel beam or column to AS 4100:2020 Section 12: exposed surface area to mass ratio k_sm for three or four sided exposure, limiting temperature T_l = 905 - 690r_f, time to reach T_l for an unprotected member (Cl.

    Standards.

    • AS/NZ: AS 4100:2020
    • US: ANSI/AISC 360-22
    • CA: CSA S16-19
    • EU: EN 1993-1-2:2005

    Limits.

    • Connections, web openings, local buckling of slender sections, composite action and the restraint of thermal expansion by the surrounding structure are not assessed.
    • Fire resistance of a floor or wall assembly (integrity and insulation) is not assessed: this is the structural adequacy of the steel member.
    • Angles, tees and welded plate sections are not provided; hollow circular sections use a simple three sided perimeter.
    • The protection is described by its thermal properties; the stickability and thickness of a tested system must be confirmed with the supplier's assessment.
    • The clause numbers follow the TensorNode pack of AS 4100:2020, which numbers the unprotected regression Cl. 12.7 and the protected route Cl. 12.6; the protected result is a rational method under Cl. 12.3(c) that needs test confirmation. The regression coefficients were reconstructed from the extracted text.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Timber Member in Fire

    What it does. Fire resistance of a timber beam or column to AS 1720.4 by the residual section method: char rate from the timber density or Table 2.5.1, the 7.0 mm uncharred layer of Eq 2.6.1, residual section, and the bending, shear or compression capacity of the residual s

    Standards.

    • AS/NZ: AS 1720.4:2019
    • US: ANSI/AWC NDS-2018
    • CA: CSA O86-19
    • EU: EN 1995-1-2:2004

    Limits.

    • Connections, members protected by gypsum board or encapsulation, cross-laminated timber panels, structural composite lumber and the charring of members that are not exposed to the standard fire are not covered.
    • Combined bending and axial force, lateral-torsional buckling of an exposed beam, notches and holes, and deflection or serviceability in fire are not assessed.
    • Only the F17 values used by the Timber Member module and custom strengths are provided; enter other AS 1720.1 grades as custom values.
    • Checked against the AS/NZS 1720.4:2019 text: the notional charring rate c = 0.4 + (280/δ)² with δ at 12 % moisture (2.5.2) or the Table 2.5.1 species values, the effective depth of charring d_c = c·t + 7.0 mm (2.6.1), the residual section with corner rounding ignored (2.7) and the capacity to AS 1720.1 with a 5 h load duration (2.2). The fire load combination follows AS/NZS 1170.0 (G + ψ_l Q). The duration factor k_1 = 0.97 for 5 h (AS 1720.1 Table 2.3) and the capacity factor φ of AS 1720.1 Table 2.1 by application category and material were read from AS 1720.1:2010; AS/NZS 1720.4 2.2 calls for the calculation to AS 1720.1, so the Table 2.1 φ is applied. Charring behind protective insulation (2.6.2) is not included. Clause numbers in the steps marked recalled are those of the cited sources.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Bored Pier

    What it does. Bored (CFA/cast-in-situ) pier: drilled hole, concrete cast in-situ.

    Standards.

    • AS/NZ: AS 2159:2009
    • US: IBC 2018, ACI CODE-318-25
    • CA: NBC 2020, CSA A23.3-19
    • EU: EN 1997-1:2004+A1:2013, EN 1992-1-1:2004+A1:2014, EN 1990:2002+A1:2005

    Limits.

    • Negative skin friction (downdrag), uplift/tension and lateral/moment loading are not included here.
    • Socket/rock-socketed piers and base cleanliness (CFA) effects need specific geotechnical input.
    • Settlement and the load-settlement response are not assessed: ultimate capacity only.
    • Pier-group effects and the pad/cap design are separate checks.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Combined Footing

    What it does. Combined footing supporting two columns: the uniform bearing pressure, the longitudinal beam moments (hogging at the columns, sagging between), the transverse cantilever moment and the one-way shear, with reinforcement.

    Standards.

    • AS/NZ: AS 3600:2018
    • US: ACI CODE-318-25
    • CA: CSA A23.3-19
    • EU: EN 1997-1:2004+A1:2013, EN 1992-1-1:2004+A1:2014, EN 1990:2002+A1:2005

    Limits.

    • A uniform pressure is assumed: where the load resultant is eccentric to the footing centroid, use a trapezoidal/strap analysis.
    • Punching shear at each column, and the strap-beam design for a true strap footing, are separate checks.
    • Differential settlement and soil-structure interaction are not modelled.
    • Top steel must be continuous over the columns and properly curtailed; detailing is the engineer's responsibility.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Eccentric Pad

    What it does. Eccentrically-loaded pad footing: biaxial bearing under N with moments Mx, My: the four corner pressures, the kern (no-uplift) check, and the flexural reinforcement.

    Standards.

    • AS/NZ: AS 3600:2018, AS 2159:2009
    • US: ACI CODE-318-25
    • CA: CSA A23.3-19
    • EU: EN 1997-1:2004+A1:2013, EN 1992-1-1:2004+A1:2014, EN 1990:2002+A1:2005

    Limits.

    • Where the resultant falls outside the kern (uplift), the partial-bearing pressure rises sharply: increase the footing size or add a tie/grade beam.
    • Punching shear, overturning and sliding are separate checks (see the Pad Footing / Pile modules).
    • Layered or soft soils and combined-footing interaction need a geotechnical model.
    • Biaxial reinforcement is sized on the governing direction; provide both directions.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Pad Foundation

    What it does. Factored loading with eccentricity, uplift, sliding and overturning; two-way reinforcement by mesh (SL/RL) or bar diameter + spacing.

    Standards.

    • AS/NZ: AS 3600:2018, AS 2159:2009
    • US: ACI CODE-318-25
    • CA: CSA A23.3-19
    • EU: EN 1997-1:2004+A1:2013, EN 1992-1-1:2004+A1:2014, EN 1990:2002+A1:2005

    Limits.

    • Punching shear at the column and one-way (beam) shear are reported in the checks but full shear-reinforcement detailing is not produced here.
    • Combined biaxial moment (M*x and M*y simultaneously) uses the dominant axis for bearing; a biaxial pressure check is required where both are significant.
    • Settlement compatibility with adjacent footings is not assessed.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Piered Beam

    What it does. Reinforced-concrete ground beam spanning between bored piers: the wall/structure line load gives the span moment and shear; the RC section is checked for flexure, minimum steel, shear and deflection.

    Standards.

    • AS/NZ: AS 3600:2018
    • US: ACI CODE-318-25
    • CA: CSA A23.3-19
    • EU: EN 1997-1:2004+A1:2013, EN 1992-1-1:2004+A1:2014, EN 1990:2002+A1:2005

    Limits.

    • Continuous multi-span beams need the support hogging moments and pattern loading considered.
    • Beam-on-ground (with bearing) behaviour and soil-structure interaction are a different model.
    • Torsion from eccentric walls and openings in the beam are separate checks.
    • Crack control for exposure and the pier-to-beam connection are assessed separately.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Post Footing

    What it does. Embedded post footing driven by lateral load, applied moment, load height, footing width/depth and soil φ/γ (embedment depth governs).

    Standards.

    • US: IBC 2018
    • CA: NBC 2020
    • EU: EN 1997-1:2004+A1:2013

    Limits.

    • For a constrained (surface-restrained) pole a different relationship applies and gives a shallower embedment: select the correct case.
    • Layered or cohesive soils, groundwater and group effects are not modelled; site-specific geotechnical advice governs.
    • Structural capacity of the post section itself is checked separately in the relevant member module.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Strip Footing

    What it does. Continuous strip footing under a wall line-load: bearing pressure, the cantilever face moment and reinforcement, and one-way shear, all per metre run.

    Standards.

    • AS/NZ: AS 3600:2018
    • US: ACI CODE-318-25
    • CA: CSA A23.3-19
    • EU: EN 1997-1:2004+A1:2013, EN 1992-1-1:2004+A1:2014, EN 1990:2002+A1:2005

    Limits.

    • Eccentric/moment-loaded walls give a non-uniform pressure: use the eccentric model.
    • Soft/layered soils, differential settlement and combined footings need a geotechnical model.
    • Concentrated loads along the wall and steps in the footing require local checks.
    • Crack control of the transverse bars is separate; the longitudinal bars are checked only for the minimum distribution steel, half at each face.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Tree Effects: Piers

    What it does. Bored pier through a tree-affected reactive (drying/swelling) zone: checks the uplift on the shaft from the reactive soil against the structure dead load plus the anchorage below the active zone, and the minimum embedment below that zone.

    Standards.

    • AS/NZ: AS 2870:2011, AS 2159:2009

    Limits.

    • Downdrag/settlement (the reverse, drying-then-wetting or consolidation case), lateral soil movement and pier bending are not covered here.
    • p_swell and f_s must come from the geotechnical investigation; they vary strongly with soil type, suction and pier construction.
    • Pier-group effects, the connecting ground-beam design and the base capacity are assessed separately (see Bored Pier and Piered Beam).
    • Heave from future tree removal and abnormal-moisture conditions (AS 2870 §1.3) must be considered.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Bondbeam

    What it does. Reinforced masonry bond beam / lintel to AS 3700: the span moment and shear from the applied load, the reinforced flexural capacity, the masonry shear capacity and the minimum reinforcement.

    Standards.

    • AS/NZ: AS 3700:2018
    • US: TMS 402-22
    • CA: CSA S304-14
    • EU: EN 1996-1-1:2005+A1:2012

    Limits.

    • Concentrated loads, point loads and arching action are not modelled here.
    • Bearing at the supports and the supporting masonry/pier are separate checks.
    • Deep-beam behaviour (short span/depth) and deflection/cracking are not assessed.
    • Bond-beam continuity over multiple spans changes the moments: model the actual condition.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Masonry Member

    What it does. Unreinforced masonry wall/member in vertical compression to AS 3700: the characteristic compressive strength from the unit strength and mortar factor, the slenderness reduction, and the design compression capacity.

    Standards.

    • AS/NZ: AS 3700:2018
    • US: TMS 402-22
    • CA: CSA S304-14
    • EU: EN 1996-1-1:2005+A1:2012

    Limits.

    • Eccentric and lateral (out-of-plane bending) loads, and concentrated bearing, are separate checks (§7.3.4/§7.4).
    • Reinforced or post-tensioned masonry uses the reinforced provisions, not this unreinforced model.
    • In-plane shear (shear walls) is a separate check.
    • Robustness (minimum thickness, lateral support spacing) and durability/exposure are separate requirements.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Masonry Pier

    What it does. Masonry pier in compression to AS 3700: the same §7.3 compression model applied to an isolated pier (engaged or freestanding) carrying a concentrated load, with the slenderness reduction.

    Standards.

    • AS/NZ: AS 3700:2018
    • US: TMS 402-22
    • CA: CSA S304-14
    • EU: EN 1996-1-1:2005+A1:2012

    Limits.

    • Bearing (local crushing) under a concentrated load and eccentric/lateral load are separate checks (§7.4).
    • Reinforced/confined piers use the reinforced provisions.
    • Combined axial-plus-bending (e.g. from an eccentric beam reaction) needs the eccentric-compression model.
    • Robustness and durability/exposure requirements are separate.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Basement Wall

    What it does. Basement wall: RC wall panel embedded within a structure (basement), propped at top (floor slab/beam) and base (footing).

    Standards.

    • AS/NZ: AS 3600:2018
    • US: ACI CODE-318-25
    • CA: CSA A23.3-19
    • EU: EN 1992-1-1:2004+A1:2014, EN 1997-1:2004+A1:2013

    Limits.

    • The propped span-moment coefficient assumes a simple triangular load; complex pressure profiles need a direct analysis.
    • Out-of-plane wall design only: in-plane (diaphragm/shear-wall) actions and the prop/diaphragm design are separate.
    • No cohesion or seismic earth pressure is included.
    • Crack control for the water-retaining/exposure case and the construction-stage (un-propped) condition must be checked separately.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Earth Pressure

    What it does. Lateral earth pressure by Rankine theory: active, at-rest or passive coefficient, the soil/surcharge/water pressure diagram, the total thrust and its line of action for use in retaining-wall and basement design.

    Standards.

    • AS/NZ: AS 4678:2002
    • US: ASCE/SEI 7-22
    • CA: NBC 2020
    • EU: EN 1997-1:2004+A1:2013

    Limits.

    • No cohesion (c′) term is included; for cohesive soils the c′ contribution and tension-crack depth must be added.
    • Seismic (dynamic) earth pressure and compaction-induced pressures are not included.
    • Layered soils and a sloping/irregular surface require a layered or Coulomb/wedge analysis.
    • This module supplies the pressure resultant only: wall stability and structural design are separate modules.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Industrial Slab

    What it does. Industrial slab-on-grade under a concentrated (wheel/post) load: the radius of relative stiffness and the Westergaard interior and edge flexural stresses, checked against the allowable concrete flexural strength.

    Standards.

    • AS/NZ: AS 3600:2018
    • US: ACI 360R-10, ACI CODE-318-25
    • CA: CSA A23.3-19
    • EU: EN 1992-1-1:2004+A1:2014, Concrete Society TR34

    Limits.

    • Corner loading (the most severe case), multiple/closely-spaced loads and dynamic/impact factors are not evaluated here.
    • Edge and corner stresses assume no load transfer: provide dowels/thickened edges or use the interior value with continuity.
    • Subgrade modulus k is load-area dependent and should be from a plate-load test; settlement is not assessed.
    • Shrinkage/curling stresses, post-tensioned and steel-fibre slabs require their own methods.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Residential Slab

    What it does. Stiffened-raft / waffle footing screening to AS 2870: for the site class and construction type it gives the deemed-to-comply stiffening-beam depth and maximum beam spacing (Table 3.1) and checks the provided raft against them.

    Standards.

    • AS/NZ: AS 2870:2011
    • US: IBC 2018, IRC 2018, ACI CODE-318-25
    • CA: NBC 2020, CSA A23.1-19, CSA A23.3-19
    • EU: EN 1992-1-1:2004+A1:2014, EN 1997-1:2004+A1:2013, EN 1990:2002+A1:2005

    Limits.

    • A deemed-to-comply screening only: Class E, large/irregular plans, two-storey or heavily-loaded structures, and sloping/cut-fill sites require a site-specific engineered design (mound analysis).
    • The engineered design moments/shears from the differential mound or dish movement are not computed here: this checks the standard-detail geometry.
    • Pad/strip footing and pier-and-beam alternatives, and stiffening for concentrated loads, are separate.
    • The reinforcement, shrinkage control and edge-beam detailing must follow AS 2870 §3.3 / §4.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Retaining Wall

    What it does. Generic cantilever retaining wall: toe and heel, base thickness, optional shear key and drained/undrained (water table) condition; stem BMD/SFD, overturning, sliding (incl.

    Standards.

    • AS/NZ: AS 4678:2002, AS 3600:2018
    • US: ACI CODE-318-25
    • CA: CSA A23.3-19
    • EU: EN 1997-1:2004+A1:2013, EN 1992-1-1:2004+A1:2014

    Limits.

    • Toe bearing is checked against the allowable pressure entered; global (slip-circle) stability is not evaluated here: confirm with the geotechnical design.
    • Seismic earth pressure is not part of this calculation: open the optional earthquake loading options under the results for the Mononobe-Okabe or Wood increment.
    • AS 4678-2002 limit states: soil strength tanφ* = Φ_nΦ_uφ tanφ' (Cl 5.1, Table 5.1(A), Table 5.2), Rankine K_a from φ*; stem strength (load case A) and stability (load case B) with Table J1 factors: fill behind 1.25, live load and surcharge 1.5, water 1.0, structure and fill on the heel 0.8 when resisting (App J3(i)). The toe bearing pressure is a service check (unfactored loads) against the allowable pressure entered. Overturning is about the toe at the underside of the base with the thrust on the stem height (the pressure over the base-thickness depth and passive resistance in front of the toe are not included).
    • The strip-load lateral effect uses a simplified uniform K_a q_s below a tanφ; a Boussinesq distribution should be used where the strip load is significant or close to the wall.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Sleeper Wall

    What it does. Sleeper wall: steel posts embedded in soil, with timber or concrete sleeper planks spanning horizontally between posts.

    Standards.

    • AS/NZ: AS 4678:2002
    • US: IBC 2018, ANSI/AWC NDS-2018, ANSI/AISC 360-22
    • CA: NBC 2020, CSA O86-19, CSA S16-19
    • EU: EN 1997-1:2004+A1:2013, EN 1993-1-1:2005+A1:2014, EN 1995-1-1:2004+A2:2014

    Limits.

    • The panel (sleeper) bending and the post-to-footing/concrete-encasement detail are separate checks.
    • Sloping backfill, surcharge from nearby footings and water pressure need explicit treatment.
    • Global stability (slip-circle) and settlement are not assessed.
    • Embedment in concrete (bored pier) vs driven post changes the resistance model.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Tree Effects: y_s

    What it does. Characteristic surface movement y_s and AS 2870 site classification, including the effect of nearby trees that dry the soil more deeply: the instability index, design suction change and depth of suction change give y_s, which trees increase by extending the ac

    Standards.

    • AS/NZ: AS 2870:2011

    Limits.

    • A screening estimate: the authoritative y_s and site class come from a site-specific geotechnical assessment to AS 2870 with measured soil suction and shrink-swell indices.
    • Layered profiles, perched water, fill and cut/fill platforms change y_s and need a layer-by-layer calculation.
    • The tree model does not capture root architecture, leaking services or future planting/removal: allow for the abnormal-moisture conditions of AS 2870 §1.3.
    • Removal of established trees can cause long-term heave (the reverse case), which must be considered separately.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Snow Loads

    What it does. Roof snow load s = s_g·C_e·μ_i to AS/NZS 1170.3:2003 for mono-pitched and duo-pitched roofs, obstructed roofs and lower roofs beside a step, with the ground snow load s_g from the snow region and the elevation (Section 5), the alpine or sub-alpine shape coeffi

    Standards.

    • AS/NZ: AS/NZS 1170.3:2003
    • US: ASCE/SEI 7-22
    • CA: NBC 2020
    • EU: EN 1991-1-3:2003+A1:2015

    Limits.

    • Table 5.2 (specific locations) and the region maps (Figures 2.1, 2.2, 5.1 to 5.7) are not coded: choose the region and enter the elevation, or enter s_g from Table 5.2.
    • Ice actions (Section 3), snowguard and obstruction lateral forces (4.2.4), drifting at projections (6.7), cylindrical and curved roofs (6.8, 7.5), multi-pitched roofs (6.5) and the additional Fig. 6.5(c) case are not designed here.
    • Combination factors for snow with other actions follow AS/NZS 1170.0 and are not applied here.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Anchor Bolt

    What it does. Fastening to concrete (cast-in or post-installed anchor group) to AS 5216: tension by steel and concrete cone breakout, shear by steel and concrete edge breakout, and the combined tension-plus-shear interaction, with edge-distance and spacing effects.

    Standards.

    • AS/NZ: AS 5216:2021
    • US: ACI CODE-318-25
    • CA: CSA A23.3-19
    • EU: EN 1992-4:2018

    Limits.

    • Pull-out/pull-through, concrete splitting, blow-out (for deep anchors near an edge) and pry-out in shear are not all evaluated here: check them for the specific anchor.
    • The group projected-area calculation is simplified; closely-spaced anchors near corners need the full A_c,N / A_c,V overlap method.
    • Seismic, fatigue and fire conditions, and anchor reinforcement (supplementary rebar) to carry breakout, are separate.
    • Post-installed anchors must use the qualified ETA/manufacturer capacities; the generic CCD values here are for preliminary sizing.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Base Plate

    What it does. Steel column base plate to AS 3600 §12.6 and AS 4100: concrete bearing with confinement √(A2/A1), plate flexure (thickness), and holding-down bolts in shear and (under uplift) tension, using a rectangular bearing stress-block at any eccentricity.

    Standards.

    • AS/NZ: AS 3600:2018, AS 4100:2020
    • US: AISC DG 1 (2nd ed.), ANSI/AISC 360-22
    • CA: CSA S16-19, CSA A23.3-19
    • EU: EN 1993-1-8:2005, EN 1992-1-1:2004+A1:2014

    Limits.

    • Concrete anchorage (cone breakout, pull-out, edge effects to AS 5216) is the Anchor Bolt module: the HD tension here assumes adequate embedment.
    • A rigid-plate, uniform/triangular bearing idealisation is used; a flexible-plate (Thornton/effective-area) refinement is not applied.
    • Biaxial moment, shear-key design, grout bedding and the column-to-plate weld are separate checks.
    • Where the required bearing block a exceeds the plate length the plate is inadequate (increase B×D_p or f′c).
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Bolts

    What it does. Single high-strength bolt capacity to AS 4100 §9.3: shear (threads in/out of the shear plane, single/double shear), ply bearing and tear-out, tension, and the combined shear-and-tension interaction.

    Standards.

    • AS/NZ: AS 4100:2020
    • US: ANSI/AISC 360-22
    • CA: CSA S16-19
    • EU: EN 1993-1-8:2005

    Limits.

    • This is a single-bolt check; the group force distribution (in-plane/out-of-plane) is the Bolt Group / Eccentric Bolt Group modules.
    • Prying action on the bolt tension and the connected-plate flexibility are not included here.
    • Long-joint and large-grip reduction factors (k_r) are taken as 1.0; apply them for joints longer than 300 mm or with packing.
    • Slip-critical serviceability, fatigue and bolt-hole net-section of the plies are separate checks.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Cleat Plate

    What it does. Fin/cleat shear connection to AS 4100 §9: the eccentric bolt group (direct shear + torsion from the eccentricity), bolt bearing on the cleat, the cleat in shear yield and net-section rupture, and the support weld for V plus the eccentric moment.

    Standards.

    • AS/NZ: AS 4100:2020
    • US: ANSI/AISC 360-22
    • CA: CSA S16-19
    • EU: EN 1993-1-8:2005

    Limits.

    • Block-shear tear-out of the cleat and the supported beam web, and beam-web bearing, are separate checks (add for coped beams).
    • The connection is treated as a pin; if it attracts moment (stiff/short), design it as a moment connection.
    • Bolt-group force uses the elastic vector method (no plastic redistribution or instantaneous-centre method).
    • Weld is taken as two vertical lines of length d_p; a full weld-group elastic analysis is the Weld Group module.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    End Plate

    What it does. Bolted moment end-plate connection to AS 4100 §9: the flange tension force from the moment is resisted by the tension-bolt rows, the bolts are checked in shear, the end plate in yield-line flexure, and the tension-flange weld is sized for the flange force.

    Standards.

    • AS/NZ: AS 4100:2020
    • US: ANSI/AISC 360-22
    • CA: CSA S16-19
    • EU: EN 1993-1-8:2005

    Limits.

    • A symmetric two-flange extended end plate on an I-section beam (UB or UC) is assumed; haunched or tension-only plates and the column-side stiffening are not modelled here. Hollow sections and channels need a different connection model (for SHS and RHS a bolted flange plate, CIDECT Design Guide 9).
    • Explicit prying force, bolt-row force distribution by stiffness, and weld-group effects under combined M+V are simplified.
    • Column web yielding/buckling/crippling opposite the flanges and any need for stiffeners are checked separately (Load Stiffener / Web Bearing).
    • Axial force in the beam is not combined here; add it to the flange force where present.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Pins

    What it does. Pin connection to AS 4100 §9.4: the pin in shear (one or more shear planes), bearing between the pin and the connected plies, and pin bending from the ply spacing.

    Standards.

    • AS/NZ: AS 4100:2020
    • US: ANSI/AISC 360-22
    • CA: CSA S16-19
    • EU: EN 1993-1-8:2005

    Limits.

    • Ply net-section tension at the pin hole is a separate check (Section 7, the lug or eye-bar design).
    • Pin rotation, wear, fatigue and the retaining detail (caps/cotters) are not covered.
    • Combined shear + bending interaction on the pin section is assessed by the individual checks; for slender pins confirm the interaction.
    • Hollow pins and tapered/threaded pins are outside this solid-round model.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Portal Knee

    What it does. Bolted moment end-plate at a portal-frame knee: the rafter/column moment and shear are resisted by the tension-bolt group, the end-plate in bending and the welds; capacities are checked against the knee actions.

    Standards.

    • AS/NZ: AS 4100:2020
    • US: ANSI/AISC 360-22
    • CA: CSA S16-19
    • EU: EN 1993-1-8:2005, EN 1993-1-1:2005+A1:2014

    Limits.

    • Detailed prying, bolt-row interaction and column-side (web/flange) checks (stiffeners, web panel shear) require the full §9 / component-method assessment.
    • A knee haunch and its weld/stiffening are designed separately (see Taper Haunch).
    • Column web panel-zone shear, flange bending and web crippling at the knee must also be checked.
    • Fatigue and the connection stiffness (for frame drift) are separate considerations.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Taper Haunch

    What it does. Tapered haunch at a portal-frame knee: the deepened (haunched) section at the knee and the rafter section at the haunch toe are checked for moment, with the lateral-torsional capacity of the unrestrained inner (compression) flange over the haunch length, plus

    Standards.

    • AS/NZ: AS 4100:2020
    • US: ANSI/AISC 360-22
    • CA: CSA S16-19
    • EU: EN 1993-1-1:2005+A1:2014

    Limits.

    • The taper means the elastic/critical section is not always at the deepest point: check intermediate sections where the moment-to-capacity ratio peaks.
    • A fly-brace to the inner flange at the haunch toe (and along the haunch) is usually required; without it the α_s reduction can govern sharply.
    • Web slenderness/stiffening at the deep end, flange-to-web welds and the sharp-end stress concentration are separate checks.
    • This is an isolated member check: frame stability, second-order effects and the connection are assessed elsewhere.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Welds

    What it does. Fillet weld capacity to AS 4100 §9.7.3: design throat from the leg size, the capacity per unit length for the electrode and weld category (SP/GP), and the check against the resultant design force per unit length.

    Standards.

    • AS/NZ: AS 4100:2020
    • US: ANSI/AISC 360-22
    • CA: CSA S16-19
    • EU: EN 1993-1-8:2005

    Limits.

    • Weld-group eccentricity (direct + torsion) and the resulting non-uniform force are the Weld Group / Eccentric Bolt Group modules.
    • The transverse-fillet directional strength increase (k_t = 1.5) is conservatively omitted.
    • Incomplete/partial-penetration butt welds and their throat definition are not covered here.
    • Fatigue, weld-metal matching to the parent steel and the parent-metal capacity at the weld are separate checks.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Beam-Column

    What it does. Steel member under combined axial compression and bending to AS 4100 §8: compression member capacity, in-plane and out-of-plane member moment checks (N + Mx), and the biaxial contour where a minor-axis moment is present.

    Standards.

    • AS/NZ: AS 4100:2020
    • US: ANSI/AISC 360-22
    • CA: CSA S16-19
    • EU: EN 1993-1-1:2005+A1:2014, EN 1990:2002+A1:2005

    Limits.

    • Members in axial tension + bending, and the amplification of moments in sway frames, are not covered here.
    • The applied moments are taken as the design (already-amplified) values; the moment distribution factor α_m should match the real bending-moment diagram.
    • Local and torsional buckling are captured only via k_f and the LTB φM_bx; slender/mono-symmetric sections may need explicit checks.
    • Connection capacity and any load eccentricity are designed separately.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Bolt Group

    What it does. Bolt group under shear plus an out-of-plane moment to AS 4100 §9: the shear is shared equally while the moment is resisted by tension that grows linearly from the group centroid; the top (extreme) bolt and the combined shear-tension interaction govern.

    Standards.

    • AS/NZ: AS 4100:2020
    • US: ANSI/AISC 360-22
    • CA: CSA S16-19
    • EU: EN 1993-1-8:2005

    Limits.

    • In-plane eccentric shear (torsion) is the Eccentric Bolt Group module; this module is for out-of-plane moment + shear.
    • Centroidal neutral axis is conservative for connections that develop a compression bearing zone (which lengthens the lever and lowers bolt tension).
    • Prying, plate flexibility and the column-side checks are not included.
    • Slip-critical serviceability and long-joint reductions are separate.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Bolt Tension

    What it does. Bolt in tension with prying to AS 4100 §9: a T-stub model adds the prying force from the flexible connected plate to the applied tension; the bolt is checked for the total and the plate thickness for prying control.

    Standards.

    • AS/NZ: AS 4100:2020
    • US: ANSI/AISC 360-22
    • CA: CSA S16-19
    • EU: EN 1993-1-8:2005

    Limits.

    • Bolt-group force distribution (the source of T*) is the Bolt Group / End Plate modules; this checks one bolt with its prying.
    • The model assumes a symmetric T-stub with the prying reaction at the plate edge; irregular geometry needs explicit treatment.
    • Plate net-section and bolt bearing are separate checks; combined external shear on the bolt is added via the combined interaction elsewhere.
    • Fatigue of bolts in tension is a separate check.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Compression Strut

    What it does. Axially-loaded steel member (strut / column) to AS 4100: section and member compression capacity with the §6.3.3 slenderness reduction, plus minor-axis and combined (biaxial) bending.

    Standards.

    • AS/NZ: AS 4100:2020
    • US: ANSI/AISC 360-22
    • CA: CSA S16-19
    • EU: EN 1993-1-1:2005+A1:2014, EN 1990:2002+A1:2005

    Limits.

    • In-plane member moment capacity φM_i and out-of-plane φM_o under combined actions (§8.4) are represented by the section-based reduced capacities: for slender members confirm the §8.4 member checks (including α_m, α_s for the unbraced length).
    • The biaxial contour exponent (1.4) is the §8.3.4 section value; member biaxial interaction (§8.4.5) may govern for slender struts.
    • Connection capacity, and local effects at load points, are checked separately.
    • Angles (EA/UEA) are mono-symmetric: the principal-axis behaviour and load eccentricity must be treated per §6 and Appendix H.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Crane Beam

    What it does. Overhead-crane runway beam: moving wheel loads positioned for the absolute-maximum moment and reaction (with impact), lateral surge on the top flange, and AS 4100 bending/shear/combined capacity.

    Standards.

    • AS/NZ: AS 4100:2020, AS 1418.18
    • US: ANSI/AISC 360-22, AISC DG 7, ASCE/SEI 7-22
    • CA: CSA S16-19, NBC 2020
    • EU: EN 1993-1-1:2005+A1:2014, EN 1993-6:2007, EN 1991-3:2006, EN 1993-1-9:2005

    Limits.

    • Web bearing and buckling under the concentrated wheel load (§5.13) and bottom-flange/web local bending are not evaluated here: check the wheel-contact and bearing-stiffener requirements separately.
    • Fatigue (AS 4100 §11) governs many runway beams: the moving-load stress range and detail category must be assessed; this module is a strength check only.
    • The lateral surge moment uses a simplified mid-span point-load model; for multiple wheels distribute the surge to the actual wheel positions where critical.
    • Monorail (lower-flange loading) and the rail-to-beam connection are not covered.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Eccentric Bolt Group

    What it does. Bolt group under in-plane eccentric shear (a bracket) to AS 4100 §9: the elastic vector method combines the direct shear with the torsional shear from the eccentric moment; the critical corner bolt governs.

    Standards.

    • AS/NZ: AS 4100:2020
    • US: ANSI/AISC 360-22
    • CA: CSA S16-19
    • EU: EN 1993-1-8:2005

    Limits.

    • Out-of-plane moment (bolt tension) is the Bolt Group module; this is in-plane torsion only.
    • The plastic ICR method (less conservative) is not used; bracket-plate flexure, block shear and weld are separate.
    • No prying or tension interaction (the load is in-plane shear).
    • Long-joint and slip-critical effects are separate.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Floor Beam

    What it does. Simply-supported steel floor beam to AS 4100: factored UDL and midspan point load, section and member (lateral-torsional) moment, shear, and the floor deflection limits (live ≤ span/360, total ≤ span/250).

    Standards.

    • AS/NZ: AS 4100:2020
    • US: ANSI/AISC 360-22
    • CA: CSA S16-19
    • EU: EN 1993-1-1:2005+A1:2014, EN 1990:2002+A1:2005

    Limits.

    • Continuous and semi-continuous beams, cantilevers and pattern loading require the relevant moment envelope.
    • Composite action with the slab (AS 2327) increases both strength and stiffness and is handled by the Composite module: here the bare-steel section is used.
    • Web bearing/buckling at supports and point loads (the Web Bearing module), and the connection design, are separate.
    • Vibration/acceleration limits for sensitive floors (e.g. AS 2670/SCI P354) are not assessed.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Load Stiffener

    What it does. Load-bearing web stiffener to AS 4100 §5.14: a pair (or pairs) of stiffeners at a bearing/point load: the bearing-yield capacity and the buckling capacity of the stiffener-plus-web strut are checked against the applied reaction.

    Standards.

    • AS/NZ: AS 4100:2020
    • US: ANSI/AISC 360-22
    • CA: CSA S16-19
    • EU: EN 1993-1-1:2005+A1:2014, EN 1990:2002+A1:2005, EN 1993-1-5:2006

    Limits.

    • Intermediate (shear) transverse stiffeners for web shear-buckling are a different check (§5.15).
    • The stiffener-to-web weld and the flange bearing/fit-up are separate detailing checks.
    • Torsional/eccentric loading of the stiffener is not included. The web bearing term R_by of §5.14.1 is left out of the yield capacity (conservative); l_e = d_1 applies if a flange is not restrained against rotation.
    • For very slender webs the unstiffened web checks (yield/buckling, §5.13) should also be confirmed.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Mullion

    What it does. Steel wall mullion / wind post to AS 4100: a vertical member spanning between floors under lateral wind pressure on its tributary width; checks bending, shear and the (governing) wind deflection.

    Standards.

    • AS/NZ: AS 4100:2020
    • US: ANSI/AISC 360-22
    • CA: CSA S16-19
    • EU: EN 1993-1-1:2005+A1:2014, EN 1990:2002+A1:2005, EN 1991-1-4:2005+A1:2010

    Limits.

    • Combined wind + axial (load-bearing mullion) needs the Beam-Column module; this is a bending member.
    • Two-way action of the cladding, point loads from transoms, and dynamic/cyclic wind effects are not modelled.
    • The deflection limit should match the cladding/glazing system requirements (which can be tighter than span/175).
    • Connections to the floor structure (which must transfer the reactions) are designed separately.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    PFC & Plate

    What it does. Built-up beam from a PFC (parallel-flange channel) with a welded plate: the combined section properties (about the composite neutral axis) and the section moment and shear capacities to AS 4100.

    Standards.

    • AS/NZ: AS 4100:2020
    • US: ANSI/AISC 360-22
    • CA: CSA S16-19
    • EU: EN 1993-1-1:2005+A1:2014, EN 1993-1-8:2005

    Limits.

    • Section-capacity (φMs) only: for an unrestrained span the member moment capacity φMbx (with αs) must be checked separately.
    • Element slenderness (plate outstand, web) and the effective section for slender elements are not auto-checked.
    • The flange-to-plate weld must be designed for the longitudinal shear flow VQ/I.
    • Combined axial and biaxial bending are outside this single-axis check.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Portal Frame

    What it does. Single-bay portal frame to AS 4100: the gravity and wind load cases give the knee and apex moments; the rafter and column (as beam-columns) are checked against their member moment capacities at the critical knee.

    Standards.

    • AS/NZ: AS 4100:2020
    • US: ANSI/AISC 360-22
    • CA: CSA S16-19
    • EU: EN 1993-1-1:2005+A1:2014, EN 1990:2002+A1:2005

    Limits.

    • Moments are the statics of a two-hinged frame with a horizontal rafter (gravity as a uniform load on the rafter, wind as a uniform load on the windward column): rafter pitch, fixed bases and sway-sensitive or multi-bay frames need a full second-order (P-Δ) analysis.
    • The knee and apex moment connections, and any haunch, are designed separately (see the Portal Knee and Taper Haunch modules).
    • Base fixity, frame imperfections and serviceability sway/deflection limits need explicit checks.
    • Member out-of-plane restraint (fly bracing near the knee under reverse moment) must be detailed.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Propped Beam

    What it does. Steel propped cantilever to AS 4100: UDL with the fixed-end (hogging) and span (sagging) moments, the wall and prop reactions, the maximum shear at the fixed end, and the deflection limit.

    Standards.

    • AS/NZ: AS 4100:2020
    • US: ANSI/AISC 360-22
    • CA: CSA S16-19
    • EU: EN 1993-1-1:2005+A1:2014, EN 1990:2002+A1:2005

    Limits.

    • Point loads, partial UDLs and settlement of the prop change the moment/reaction distribution and are not modelled here.
    • The elastic distribution assumes the prop does not lift off and the fixed end does not yield (no moment redistribution taken).
    • The hogging-region bottom-flange restraint must be confirmed for the member moment capacity used.
    • The moment connection at the fixed end and the prop connection are designed separately.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Roof Beam

    What it does. Steel roof beam/rafter to AS 4100: gravity (1.2G + 1.5Q) and net wind-uplift (0.9G + Wu) load cases, section and member moment, shear, and the imposed/wind deflection limits.

    Standards.

    • AS/NZ: AS 4100:2020
    • US: ANSI/AISC 360-22
    • CA: CSA S16-19
    • EU: EN 1993-1-1:2005+A1:2014, EN 1990:2002+A1:2005

    Limits.

    • Continuous rafters, portal-rafter haunches and purlin-braced systems need the specific restraint and moment pattern (the Portal Frame module covers the frame).
    • The uplift restraint of the bottom flange (fly braces / purlin bridging) must be confirmed; this module checks capacity but does not design the braces.
    • Combined axial (rafter thrust) with bending is a beam-column action (use the Beam-Column module).
    • Wind pressures themselves come from the Wind modules; here W_u is the resulting member uplift line load.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Shelf Angle

    What it does. Shelf angle / masonry support angle to AS 4100: the eccentric brick load bends the angle leg; the leg bending capacity and the fixing-bolt shear back to the structure are checked per metre.

    Standards.

    • AS/NZ: AS 4100:2020
    • US: ANSI/AISC 360-22
    • CA: CSA S16-19
    • EU: EN 1993-1-1:2005+A1:2014, EN 1993-1-8:2005

    Limits.

    • Bolt tension/prying from the load eccentricity (the couple back to the wall) should also be checked: this focuses on leg bending and bolt shear.
    • The supporting structure (slab edge, beam) and the cast-in/anchor capacity are separate.
    • Torsion of the angle and deflection/rotation limits (to control the gap/movement joint) are not assessed.
    • Differential movement and the bedding/soft-joint detail under the angle are detailing items.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Steel Column

    What it does. Axially-loaded steel column to AS 4100 §6: section capacity (yield), member capacity (flexural buckling) with user-selected end fixity per axis (Le = ke·L), and the slenderness limit.

    Standards.

    • AS/NZ: AS 4100:2020
    • US: ANSI/AISC 360-22
    • CA: CSA S16-19
    • EU: EN 1993-1-1:2005+A1:2014, EN 1990:2002+A1:2005

    Limits.

    • Combined actions (N + M), and the amplification of moments in sway frames, are beam-column checks not covered here.
    • Local buckling of slender plate elements is captured only through k_f from the library; stiffened/custom sections need explicit form-factor calculation.
    • Torsional and flexural-torsional buckling (relevant for some mono-symmetric and cruciform sections) are not evaluated.
    • Base and cap connections, and any load eccentricity, are designed separately.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Steel Member

    What it does. Hot-rolled steel member (UB / UC / PFC / TFB) to AS 4100: section moment, member lateral-torsional buckling, shear and section compression.

    Standards.

    • AS/NZ: AS 4100:2020
    • US: ANSI/AISC 360-22
    • CA: CSA S16-19
    • EU: EN 1993-1-1:2005+A1:2014, EN 1990:2002+A1:2005

    Limits.

    • Lateral-torsional buckling of a PFC uses the channel warping constant with the load through the shear centre; a load on the web face twists the channel and needs a detailed §5.6 analysis.
    • Angles (EA/UEA) are taken with the long leg vertical and the load through the section: the section capacity is about the horizontal geometric axis (deflection held to the vertical plane, §5.7.1, as the Lintel module), and the member capacity takes the angle free to deflect between the lateral restraints (§5.7.2): principal-axis moments checked by §8.3.4 and §8.4.5, with φM_bx from §5.6.1.3 (I_w = 0) over L_e. Geometric properties ignore the root fillet. Torsion from a load applied off the shear centre (on a leg face) is not included.
    • SHS and RHS use the closed-section torsion constant, so lateral buckling only reduces deep narrow RHS over long lengths; CHS do not buckle laterally (α_s = 1). The library Z_e allows for section slenderness (§5.2).
    • Member compression buckling φN_c (§6.3, slenderness λn) and combined bending+axial interaction (§8) are not evaluated here: section yield only.
    • Connection capacity, web bearing/buckling at supports and serviceability deflection are checked separately.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    T / Angle Lintel

    What it does. Steel lintel (angle, PFC or flat) over a masonry opening: masonry arching (triangular) load to AS 3700, bending and deflection to AS 4100, and support bearing.

    Standards.

    • AS/NZ: AS 4100:2020, AS 3700:2018
    • US: ANSI/AISC 360-22
    • CA: CSA S16-19
    • EU: EN 1993-1-1:2005+A1:2014, EN 1996-1-1:2005+A1:2012

    Limits.

    • Angle lintels bend about the geometric axis parallel to the horizontal leg (the masonry holds the angle against twisting about its principal axes): I_x and Z_e are computed from the leg dimensions (root fillets ignored), with the long leg vertical; Z_e is the elastic modulus to the toe of the vertical leg, reduced where the leg slenderness λ_e = (b/t)√(f_y/250) exceeds the AS 4100 Table 5.2 outstand yield limit 16. The library principal-axis values do not apply to this case.
    • Single-angle and unequal-angle lintels are mono-symmetric and load eccentrically (the masonry sits to one side): torsion and the resulting flange stresses must be checked, or a symmetric section (PFC pair / flat-and-angle) used, for wide or heavily-loaded openings.
    • The arching model assumes a solid masonry panel of sufficient length each side of the opening; for openings near corners, control joints or short returns, take the full wall load (no arching).
    • Composite/“box” lintels (angle + plate, two PFCs) and the lateral restraint to the heel of an angle are not modelled here.
    • Fire rating, corrosion protection and the differential deflection between leaves of a cavity wall are checked separately.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Tension Member

    What it does. Axially-loaded steel tension member to AS 4100 §7.2: gross-section yield and net-section fracture, including the end-connection eccentricity factor kt and net-area (bolt-hole) reduction.

    Standards.

    • AS/NZ: AS 4100:2020
    • US: ANSI/AISC 360-22
    • CA: CSA S16-19
    • EU: EN 1993-1-1:2005+A1:2014, EN 1990:2002+A1:2005, EN 1993-1-8:2005

    Limits.

    • Block-shear failure at bolted end connections (§7.3-type tear-out) can govern for short connections and is not evaluated here.
    • Threaded rods, cables and members with significant bending (use the Beam-Column approach) fall outside this check.
    • Serviceability (stretch, vibration of slender ties) and fatigue are assessed separately where relevant.
    • k_t is taken from Table 7.3.2 for the section type and the connection chosen; tee sections (0.90 in Table 7.3.2) and back-to-back pairs of angles, channels or tees are not in the section list and take a chosen value. Hollow sections take k_t = 1.0 for a connection all round the tube (Clause 7.3.1); a slotted gusset through the tube is outside Table 7.3.2 (Clause 7.3.2 then sends the member to Section 8 with k_t = 1.0).
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Web Bearing

    What it does. Steel web bearing under a concentrated load/reaction to AS 4100 §5.13: bearing yield and bearing buckling (web as a column), with the 1:2.5 flange dispersion and the interior/end stiff-bearing condition.

    Standards.

    • AS/NZ: AS 4100:2020
    • US: ANSI/AISC 360-22
    • CA: CSA S16-19
    • EU: EN 1993-1-1:2005+A1:2014, EN 1990:2002+A1:2005, EN 1993-1-5:2006

    Limits.

    • Combined bearing with high coexisting shear or moment at the load point (interaction) is not evaluated here.
    • Hollow sections and webs with openings near the load are outside this check.
    • The 1:1 dispersion is taken to mid-depth of the web, which is the neutral axis of every section in the library.
    • Where a stiffener is required, its design (yield, buckling, weld) is a separate calculation.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Weld Group

    What it does. Fillet weld group under in-plane eccentric shear to AS 4100 §9.7: the welds are treated as unit-throat line elements; the direct shear and the torsional shear from the eccentric moment are combined at the critical point and checked against the per-length capac

    Standards.

    • AS/NZ: AS 4100:2020
    • US: ANSI/AISC 360-22
    • CA: CSA S16-19
    • EU: EN 1993-1-8:2005

    Limits.

    • Out-of-plane eccentricity (weld tension) and combined in/out-of-plane loading need a fuller analysis.
    • Only two configurations (two vertical lines, full box) are built in; other patterns require the general line-element properties.
    • The directional strength enhancement and weld-to-parent-metal capacity are separate checks.
    • Fatigue and incomplete-penetration butt welds are not covered.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Circular Column

    What it does. Circular timber column / pole to AS 1720.1 §3.3: axial compression with the slenderness stability factor k12 on the round section, plus optional bending (no lateral-torsional buckling for a circular section).

    Standards.

    • AS/NZ: AS 1720.1:2010
    • US: ANSI/AWC NDS-2018
    • CA: CSA O86-19
    • EU: EN 1995-1-1:2004+A2:2014, EN 1990:2002+A1:2005

    Limits.

    • Taper along a pole is not modelled: use the critical (smallest) effective diameter.
    • Bearing/crushing at the ends and the base/cap connections are separate checks.
    • Combined bending uses a linear interaction; for large moments use the detailed §3.5 interaction.
    • Durability/preservative treatment for in-ground poles is a separate (critical) consideration.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    F17 Span Tables

    What it does. Maximum span for an F-grade timber member: the bending-limited span (φMb = wL²/8) and the deflection-limited span (δ = L/limit) for a chosen section, spacing and load; the lesser governs.

    Standards.

    • AS/NZ: AS 1720.1:2010
    • US: ANSI/AWC NDS-2018, IRC 2018
    • CA: CSA O86-19, NBC 2020
    • EU: EN 1995-1-1:2004+A2:2014, EN 1990:2002+A1:2005

    Limits.

    • Indicative span only: confirm against the published AS 1720.1 span tables and the actual restraint, load duration and moisture condition.
    • Shear, bearing at supports and lateral stability (k12 < 1 for unrestrained members) are not checked here.
    • Creep deflection (j2, k1) for long-term loads is not applied: total deflection may govern more tightly.
    • Notches, holes, connections and vibration are separate considerations.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Joint

    What it does. Timber joint (bolted / nailed / screwed) lateral capacity to AS 1720.1 §4: the design capacity from the characteristic fastener capacity, the number of fasteners and the modification factors, checked against the design action.

    Standards.

    • AS/NZ: AS 1720.1:2010
    • US: ANSI/AWC NDS-2018
    • CA: CSA O86-19
    • EU: EN 1995-1-1:2004+A2:2014

    Limits.

    • Withdrawal (axial) capacity of nails/screws is a separate check, not covered here.
    • Q_k must come from the correct joint-group table; an incorrect group can change the capacity substantially.
    • Splitting, row shear-out and the timber member net-section are separate checks.
    • Moisture condition, preservative treatment and steel side-plate effects modify the capacity.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Timber Column

    What it does. Timber column/post to AS 1720.1 §3.3: axial compression with the slenderness stability factor k12 about both axes; the worse axis governs.

    Standards.

    • AS/NZ: AS 1720.1:2010
    • US: ANSI/AWC NDS-2018
    • CA: CSA O86-19
    • EU: EN 1995-1-1:2004+A2:2014, EN 1990:2002+A1:2005

    Limits.

    • Bracing that differs between axes should be entered via the effective length; this uses one k_e for both axes.
    • Bearing/crushing at the ends and the base/cap connections are separate checks.
    • Combined bending uses a linear interaction; for large moments use the detailed §3.5 interaction.
    • Built-up/spaced columns are outside this solid-section model.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Timber Floor Beam

    What it does. Sawn/LVL timber floor beam to AS 1720.1: bending with lateral-stability k12, shear, and the creep-affected total deflection plus the live-load deflection.

    Standards.

    • AS/NZ: AS 1720.1:2010
    • US: ANSI/AWC NDS-2018
    • CA: CSA O86-19
    • EU: EN 1995-1-1:2004+A2:2014, EN 1990:2002+A1:2005

    Limits.

    • Notches, holes, and bearing/crushing at supports are separate checks.
    • Continuous/multi-span and cantilever conditions change M*, V* and deflection.
    • Connection and end-bearing capacity are designed separately.
    • Vibration (floor bounce) for long spans should be assessed where occupant comfort governs.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Timber Member

    What it does. Sawn / glulam rectangular timber member to AS 1720.1: bending, shear, compression, tension and combined actions, with the k-factor capacity model and slenderness (k12) stability.

    Standards.

    • AS/NZ: AS 1720.1:2010
    • US: ANSI/AWC NDS-2018
    • CA: CSA O86-19
    • EU: EN 1995-1-1:2004+A2:2014, EN 1990:2002+A1:2005

    Limits.

    • The bending slenderness coefficient S1 here uses a discrete-restraint form: the actual S1 depends on the restraint configuration (continuous, discrete, or unrestrained, AS 1720.1 §3.2.3 and Table 3.1); confirm S1 for the real restraint condition.
    • Combined bending+axial uses a linear interaction as an indicator: apply the AS 1720.1 §3.5 interaction (with the relevant stability terms) for the final check.
    • Bearing (§3.2.6), notched/connection capacity, duration-of-load creep deflection (j2/j3) and serviceability deflection are checked separately.
    • Glulam/LVL combination factors and size/depth factors (where applicable) must be applied to the characteristic strengths before entry.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Timber Roof Beam

    What it does. Timber roof beam/rafter to AS 1720.1: gravity (G + Q) and wind (including net uplift) load cases, bending with k12, shear, and deflection.

    Standards.

    • AS/NZ: AS 1720.1:2010
    • US: ANSI/AWC NDS-2018
    • CA: CSA O86-19
    • EU: EN 1995-1-1:2004+A2:2014, EN 1990:2002+A1:2005

    Limits.

    • Under net uplift the normally-compressed edge changes: confirm the bottom-edge lateral restraint for that case.
    • Sloped-rafter axial (thrust) effects and purlin point loads are not modelled.
    • Continuous/overhang conditions and connection design are separate.
    • Ponding on low-slope roofs should be checked where relevant.
    • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
    • Results depend on the values you enter and on the units shown beside each field.
    • The module follows the edition named for each code system; a later edition may differ.
    Symbols

    What it does. Notation and symbol reference: the common symbols used across the Australian Standards (general, actions, concrete, steel, timber, masonry, geotechnical) with their meaning and source standard.

    Standards.

      Limits.

      • Not exhaustive: consult the specific standard for its full symbol list.
      • Some symbols have context-dependent meanings; the table gives the common usage.
      • Greek-letter rendering depends on the display font.
      • This is a reference aid, not a normative source.
      • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
      • Results depend on the values you enter and on the units shown beside each field.
      • The module follows the edition named for each code system; a later edition may differ.
      Unit Conversions

      What it does. Engineering unit converter: enter a value in the SI base unit of a quantity (force, stress, moment, length, line load or area) and read it in all the common alternative units.

      Standards.

        Limits.

        • Temperature, energy, density and other quantities are not included in this set.
        • Significant figures are for display; carry full precision in calculations.
        • Compound/derived units beyond those listed must be converted manually.
        • Always confirm the unit system expected by the receiving calculation or code.
        • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
        • Results depend on the values you enter and on the units shown beside each field.
        • The module follows the edition named for each code system; a later edition may differ.
        Flag

        What it does. Wind drag on a flag/banner and pole base moment: flag mass, shape, height and length.

        Standards.

        • AS/NZ: AS/NZS 1170.2:2021
        • US: ASCE/SEI 7-22
        • CA: NBC 2020
        • EU: EN 1991-1-4:2005+A1:2010

        Limits.

        • Drag on the flagpole shaft (a separate line load) is not added here and must be included in the pole design.
        • Dynamic flutter/fatigue of the flag and pole is not assessed.
        • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
        • Results depend on the values you enter and on the units shown beside each field.
        • The module follows the edition named for each code system; a later edition may differ.
        Free Roof / Canopy

        What it does. Net wind pressure and uplift on a free/canopy roof: canopy & average height, width, length, blocked underneath, enclosed sides and roof area.

        Standards.

        • AS/NZ: AS/NZS 1170.2:2021
        • US: ASCE/SEI 7-22
        • CA: NBC 2020
        • EU: EN 1991-1-4:2005+A1:2010

        Limits.

        • Only the overall net coefficient is evaluated; leading-edge and corner local pressure zones for cladding are not included.
        • Pitched (duo-pitch) and curved free roofs use different coefficient sets: applicable to monoslope canopies as presented.
        • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
        • Results depend on the values you enter and on the units shown beside each field.
        • The module follows the edition named for each code system; a later edition may differ.
        Hoarding

        What it does. Solid hoarding / freestanding wall: drag force and base overturning moment per panel.

        Standards.

        • AS/NZ: AS/NZS 1170.2:2021
        • US: ASCE/SEI 7-22
        • CA: NBC 2020
        • EU: EN 1991-1-4:2005+A1:2010

        Limits.

        • Per-panel result; corner and end panels of a long hoarding attract higher local coefficients and should be checked separately.
        • Footing/post design for the reported base moment is performed in the footing modules.
        • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
        • Results depend on the values you enter and on the units shown beside each field.
        • The module follows the edition named for each code system; a later edition may differ.
        Monoslope Roof

        What it does. Wind pressures on a monoslope (skillion) roof to AS 1170.2 §5.4: the external pressure coefficients for the upwind/downwind slopes combined with the internal pressure give the net uplift and downward design pressures.

        Standards.

        • AS/NZ: AS/NZS 1170.2:2021
        • US: ASCE/SEI 7-22
        • CA: NBC 2020
        • EU: EN 1991-1-4:2005+A1:2010

        Limits.

        • Local pressure factors (K_l) at edges, ridges and corners must be added for cladding/fixing design.
        • Combined wall-plus-roof and frictional drag are separate; this is the roof surface only.
        • Parapets, canopies and unusual geometries change the coefficients.
        • Dynamic response (C_dyn) is taken as unity for typical stiff roofs: check for flexible roofs.
        • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
        • Results depend on the values you enter and on the units shown beside each field.
        • The module follows the edition named for each code system; a later edition may differ.
        Purlin & Girt Loads

        What it does. Purlin/girt member under wind to AS 4100: the wind line load over the member spacing gives the span moment, shear and deflection, checked against the section/member capacities (single or lapped/continuous).

        Standards.

        • AS/NZ: AS 4100:2020
        • US: ASCE/SEI 7-22, ANSI/AISC 360-22
        • CA: NBC 2020, CSA S16-19
        • EU: EN 1991-1-4:2005+A1:2010, EN 1993-1-1:2005+A1:2014

        Limits.

        • Cold-formed purlin design (the common case) follows AS/NZS 4600 and the manufacturer's tables: not this hot-rolled check.
        • The bridging/fly-brace layout and the lap design for continuous purlins are separate.
        • Combined axial (strut/tie action in the roof plane) is not included.
        • Local pressure factors for edge/corner zones must be applied to the wind pressure.
        • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
        • Results depend on the values you enter and on the units shown beside each field.
        • The module follows the edition named for each code system; a later edition may differ.
        Terrain Change

        What it does. Wind terrain/height multiplier with a terrain-category change to AS 1170.2 §4.2: the lag-distance interpolation between the upwind and downwind categories gives the governing M_z,cat, the design wind speed and the dynamic pressure.

        Standards.

        • AS/NZ: AS/NZS 1170.2:2021
        • US: ASCE/SEI 7-22
        • CA: NBC 2020
        • EU: EN 1991-1-4:2005+A1:2010

        Limits.

        • Multiple terrain changes and very short fetches need the full §4.2.3 averaging procedure.
        • Topographic (hill/escarpment) effects M_t and shielding M_s are separate calculations.
        • This gives the site wind speed/pressure only: the structure pressure coefficients are applied in the Wind Loads module.
        • Cyclonic regions (C, D) require the appropriate region factors and importance treatment.
        • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
        • Results depend on the values you enter and on the units shown beside each field.
        • The module follows the edition named for each code system; a later edition may differ.
        Wind Actions

        What it does. Site wind speed and design pressures with importance level, design life, roof pitch, average/roof height, blocked-underneath internal pressure and area-reduction Ka.

        Standards.

        • AS/NZ: AS/NZS 1170.2:2021
        • US: ASCE/SEI 7-22
        • CA: NBC 2020
        • EU: EN 1991-1-4:2005+A1:2010

        Limits.

        • External pressure coefficients shown are representative envelope values; rectangular-building tables (AS 1170.2 §5.4) should be applied per surface and zone for the final design.
        • Cyclonic regions C and D include the F_c/F_d uncertainty factor but not cladding-specific local pressure factors (K_l) for fixings: check separately.
        • Combination factor K_c assumes correlated action on a single surface; multi-surface load cases must be enumerated.
        • Checks only the clauses and equations the module lists; it does not replace the rest of the standard.
        • Results depend on the values you enter and on the units shown beside each field.
        • The module follows the edition named for each code system; a later edition may differ.

        See also the Terms of use (including the limitation of liability to the extent the law permits).