TensorNodeOpen TensorNode
Home / Products

Products and modules

Every design module in TensorNode, with the standards and editions it supports in each code system. Filter by material or code region, search, sort, and switch between cards and a table.

96 modules

  • Analysis

    Analysis

    General single-span beam analysis: reactions, maximum bending moment and shear, and elastic deflection for a uniform and/or point load on a simply-supported, cantilever, propped-cantilever or fixed-end beam.

    • Anchor Bolt

      Steel connections

      Fastening to concrete (cast-in or post-installed anchor group) to AS 5216: tension by steel and concrete cone breakout, shear by steel and concrete edge breakout, and the combined tension-plus-shear interaction, with edge-distance and spacing effects.

      • AS/NZ AS 5216:2021
      • US ACI CODE-318-25
      • CA CSA A23.3-19
      • EU EN 1992-4:2018
    • Base Plate

      Steel connections

      Steel column base plate to AS 3600 §12.6 and AS 4100: concrete bearing with confinement √(A2/A1), plate flexure (thickness), and holding-down bolts in shear and (under uplift) tension, using a rectangular bearing stress-block at any eccentricity.

      • AS/NZ AS 3600:2018, AS 4100:2020
      • US AISC DG 1 (2nd ed.), ANSI/AISC 360-22
      • CA CSA S16-19, CSA A23.3-19
      • EU EN 1993-1-8:2005, EN 1992-1-1:2004+A1:2014
    • Basement Wall

      Retaining walls and slabs

      Basement wall: RC wall panel embedded within a structure (basement), propped at top (floor slab/beam) and base (footing).

      • AS/NZ AS 3600:2018
      • US ACI CODE-318-25
      • CA CSA A23.3-19
      • EU EN 1992-1-1:2004+A1:2014, EN 1997-1:2004+A1:2013
    • Beam Shear

      Concrete

      Reinforced-concrete beam shear to AS 3600 §8.2: concrete contribution φVuc plus shear-reinforcement φVus (vertical stirrups), with the minimum-reinforcement and maximum-spacing detailing and the web-crushing limit.

      • AS/NZ AS 3600:2018
      • US ACI CODE-318-25
      • CA CSA A23.3-19
      • EU EN 1992-1-1:2004+A1:2014
    • Beam Torsion

      Concrete

      Reinforced-concrete beam torsion to AS 3600:2018 Cl.

      • AS/NZ AS 3600:2018
      • US ACI CODE-318-25
      • CA CSA A23.3-19
      • EU EN 1992-1-1:2004+A1:2014
    • Beam-Column

      Steel members

      Steel member under combined axial compression and bending to AS 4100 §8: compression member capacity, in-plane and out-of-plane member moment checks (N + Mx), and the biaxial contour where a minor-axis moment is present.

      • AS/NZ AS 4100:2020
      • US ANSI/AISC 360-22
      • CA CSA S16-19
      • EU EN 1993-1-1:2005+A1:2014, EN 1990:2002+A1:2005
    • Bolt Group

      Steel members

      Bolt group under shear plus an out-of-plane moment to AS 4100 §9: the shear is shared equally while the moment is resisted by tension that grows linearly from the group centroid; the top (extreme) bolt and the combined shear-tension interaction govern.

      • AS/NZ AS 4100:2020
      • US ANSI/AISC 360-22
      • CA CSA S16-19
      • EU EN 1993-1-8:2005
    • Bolt Tension

      Steel members

      Bolt in tension with prying to AS 4100 §9: a T-stub model adds the prying force from the flexible connected plate to the applied tension; the bolt is checked for the total and the plate thickness for prying control.

      • AS/NZ AS 4100:2020
      • US ANSI/AISC 360-22
      • CA CSA S16-19
      • EU EN 1993-1-8:2005
    • Bolts

      Steel connections

      Single high-strength bolt capacity to AS 4100 §9.3: shear (threads in/out of the shear plane, single/double shear), ply bearing and tear-out, tension, and the combined shear-and-tension interaction.

      • AS/NZ AS 4100:2020
      • US ANSI/AISC 360-22
      • CA CSA S16-19
      • EU EN 1993-1-8:2005
    • Bondbeam

      Masonry

      Reinforced masonry bond beam / lintel to AS 3700: the span moment and shear from the applied load, the reinforced flexural capacity, the masonry shear capacity and the minimum reinforcement.

      • AS/NZ AS 3700:2018
      • US TMS 402-22
      • CA CSA S304-14
      • EU EN 1996-1-1:2005+A1:2012
    • Bored Pier

      Footings

      Bored (CFA/cast-in-situ) pier: drilled hole, concrete cast in-situ.

      • AS/NZ AS 2159:2009
      • US IBC 2018, ACI CODE-318-25
      • CA NBC 2020, CSA A23.3-19
      • EU EN 1997-1:2004+A1:2013, EN 1992-1-1:2004+A1:2014, EN 1990:2002+A1:2005
    • Circular Column

      Timber

      Circular timber column / pole to AS 1720.1 §3.3: axial compression with the slenderness stability factor k12 on the round section, plus optional bending (no lateral-torsional buckling for a circular section).

      • AS/NZ AS 1720.1:2010
      • US ANSI/AWC NDS-2018
      • CA CSA O86-19
      • EU EN 1995-1-1:2004+A2:2014, EN 1990:2002+A1:2005
    • Cleat Plate

      Steel connections

      Fin/cleat shear connection to AS 4100 §9: the eccentric bolt group (direct shear + torsion from the eccentricity), bolt bearing on the cleat, the cleat in shear yield and net-section rupture, and the support weld for V plus the eccentric moment.

      • AS/NZ AS 4100:2020
      • US ANSI/AISC 360-22
      • CA CSA S16-19
      • EU EN 1993-1-8:2005
    • Column Biaxial

      Concrete

      RC column under axial load with biaxial bending to AS 3600 §10.6.3, the P-M interaction is built by strain compatibility about each axis, with reinforcement placed on all four faces (top/bottom bars resist X-axis bending, side bars resist Y-axis bending, both

      • AS/NZ AS 3600:2018
      • US ACI CODE-318-25
      • CA CSA A23.3-19
      • EU EN 1992-1-1:2004+A1:2014
    • Column Interaction

      Concrete

      Rectangular reinforced-concrete column to AS 3600 §10: squash load, full N-M interaction by strain compatibility, biaxial bending about both axes, capacity-point table and slenderness screen.

      • AS/NZ AS 3600:2018
      • US ACI CODE-318-25
      • CA CSA A23.3-19
      • EU EN 1992-1-1:2004+A1:2014
    • Combined Footing

      Footings

      Combined footing supporting two columns: the uniform bearing pressure, the longitudinal beam moments (hogging at the columns, sagging between), the transverse cantilever moment and the one-way shear, with reinforcement.

      • AS/NZ AS 3600:2018
      • US ACI CODE-318-25
      • CA CSA A23.3-19
      • EU EN 1997-1:2004+A1:2013, EN 1992-1-1:2004+A1:2014, EN 1990:2002+A1:2005
    • Composite Member

      Composite

      Simply-supported composite steel-and-concrete beam to AS 2327: a library steel section acting compositely with a profiled-deck slab (Bondek / Condek / KingFlor / RF / solid), with the effective flange width, the plastic composite moment capacity, the degree of

      • AS/NZ AS 2327:2017
      • US ANSI/AISC 360-22
      • CA CSA S16-19
      • EU EN 1994-1-1:2004, EN 1993-1-1:2005+A1:2014, EN 1990:2002+A1:2005
    • Compression Strut

      Steel members

      Axially-loaded steel member (strut / column) to AS 4100: section and member compression capacity with the §6.3.3 slenderness reduction, plus minor-axis and combined (biaxial) bending.

      • AS/NZ AS 4100:2020
      • US ANSI/AISC 360-22
      • CA CSA S16-19
      • EU EN 1993-1-1:2005+A1:2014, EN 1990:2002+A1:2005
    • Concrete Durability and Cover

      Concrete

      Durability and cover to reinforcement to AS 3600:2018 Section 4: exposure classification (Table 4.3, with the sulfate and saline soil tables 4.8.1 and 4.8.2), minimum f'c and curing (Table 4.4, with the abrasion and freezing and thawing limits of Table 4.6 and

      • AS/NZ AS 3600:2018
      • US ACI CODE-318-25
      • CA CSA A23.1-19
      • EU EN 1992-1-1:2004+A1:2014
    • Concrete Wall

      Concrete

      RC wall in compression by the AS 3600 §11.5.3 simplified method: the design axial capacity per metre from the wall thickness, the load eccentricity and the slenderness-derived additional eccentricity, with the minimum vertical reinforcement.

      • AS/NZ AS 3600:2018
      • US ACI CODE-318-25
      • CA CSA A23.3-19
      • EU EN 1992-1-1:2004+A1:2014
    • Corbel / Bracket

      Concrete

      Reinforced-concrete corbel / bracket to AS 3600: shear-friction with the casting-interface condition (monolithic / roughened / smooth / against steel), main tension tie and closed ties from the vertical and horizontal actions, bearing and the maximum shear lim

      • AS/NZ AS 3600:2018
      • US ACI CODE-318-25
      • CA CSA A23.3-19
      • EU EN 1992-1-1:2004+A1:2014
    • Crack Control

      Concrete

      Crack control for RC beams/slabs by the AS 3600 §8.6.2.2 deemed-to-comply method: the serviceability steel stress is checked against the larger of the bar-diameter and bar-spacing limits (Tables 8.6.2.2(A) and (B), selected w'max), plus the minimum tensile rei

      • AS/NZ AS 3600:2018
      • US ACI CODE-318-25
      • CA CSA A23.3-19
      • EU EN 1992-1-1:2004+A1:2014
    • Crane Beam

      Steel members

      Overhead-crane runway beam: moving wheel loads positioned for the absolute-maximum moment and reaction (with impact), lateral surge on the top flange, and AS 4100 bending/shear/combined capacity.

      • AS/NZ AS 4100:2020, AS 1418.18
      • US ANSI/AISC 360-22, AISC DG 7, ASCE/SEI 7-22
      • CA CSA S16-19, NBC 2020
      • EU EN 1993-1-1:2005+A1:2014, EN 1993-6:2007, EN 1991-3:2006, EN 1993-1-9:2005
    • Dead & Live Loads

      Analysis

      Load takedown: builds the permanent (G) action from its components and the imposed (Q) action, applies the AS/NZS 1170.0 ULS and SLS combinations, and converts to a design line load over a tributary width.

      • AS/NZ AS/NZS 1170.1:2002
      • US ASCE/SEI 7-22
      • CA NBC 2020
      • EU EN 1990:2002+A1:2005
    • Deep Beam

      Concrete

      RC deep beam (span/depth < 2) by strut-and-tie to AS 3600 §7: a diagonal concrete strut carries the load to the supports and a bottom tie carries the tension; the strut, tie, node bearing and diagonal-compression limit are checked.

      • AS/NZ AS 3600:2018
      • US ACI CODE-318-25
      • CA CSA A23.3-19
      • EU EN 1992-1-1:2004+A1:2014
    • Development & Laps

      Concrete

      Reinforcement development and lap lengths to AS 3600 §13: basic tension development length Lsy.tb (with the bar-position, cover/confinement and concrete-strength factors), compression development, and tension/compression lap lengths.

      • AS/NZ AS 3600:2018
      • US ACI CODE-318-25
      • CA CSA A23.3-19
      • EU EN 1992-1-1:2004+A1:2014
    • Drainage

      Drainage

      Pipe / drain capacity by the Manning equation: the full-bore velocity and flow capacity for a circular pipe at a given grade and roughness, with a self-cleansing-velocity check and an optional capacity-versus-demand check.

      • AS/NZ AS/NZS 3500.3
      • US IPC 2018, ASCE/SEI 7-22
      • CA NPC 2020, NBC 2020
      • EU EN 12056-3, EN 752
    • Earth Pressure

      Retaining walls and slabs

      Lateral earth pressure by Rankine theory: active, at-rest or passive coefficient, the soil/surcharge/water pressure diagram, the total thrust and its line of action for use in retaining-wall and basement design.

      • AS/NZ AS 4678:2002
      • US ASCE/SEI 7-22
      • CA NBC 2020
      • EU EN 1997-1:2004+A1:2013
    • Earthquake Design Category

      Earthquake actions

      Earthquake Design Category (EDC) determination to AS 1170.4 §2: from the hazard product kp·Z, the site sub-soil class, the structure height and the importance level, giving the required analysis method.

      • AS/NZ AS 1170.4:2007
      • US ASCE/SEI 7-22
      • CA NBC 2020
      • EU EN 1998-1:2004+A1:2013
    • Eccentric Bolt Group

      Steel members

      Bolt group under in-plane eccentric shear (a bracket) to AS 4100 §9: the elastic vector method combines the direct shear with the torsional shear from the eccentric moment; the critical corner bolt governs.

      • AS/NZ AS 4100:2020
      • US ANSI/AISC 360-22
      • CA CSA S16-19
      • EU EN 1993-1-8:2005
    • Eccentric Pad

      Footings

      Eccentrically-loaded pad footing: biaxial bearing under N with moments Mx, My: the four corner pressures, the kern (no-uplift) check, and the flexural reinforcement.

      • AS/NZ AS 3600:2018, AS 2159:2009
      • US ACI CODE-318-25
      • CA CSA A23.3-19
      • EU EN 1997-1:2004+A1:2013, EN 1992-1-1:2004+A1:2014, EN 1990:2002+A1:2005
    • End Plate

      Steel connections

      Bolted moment end-plate connection to AS 4100 §9: the flange tension force from the moment is resisted by the tension-bolt rows, the bolts are checked in shear, the end plate in yield-line flexure, and the tension-flange weld is sized for the flange force.

      • AS/NZ AS 4100:2020
      • US ANSI/AISC 360-22
      • CA CSA S16-19
      • EU EN 1993-1-8:2005
    • F17 Span Tables

      Timber

      Maximum span for an F-grade timber member: the bending-limited span (φMb = wL²/8) and the deflection-limited span (δ = L/limit) for a chosen section, spacing and load; the lesser governs.

      • AS/NZ AS 1720.1:2010
      • US ANSI/AWC NDS-2018, IRC 2018
      • CA CSA O86-19, NBC 2020
      • EU EN 1995-1-1:2004+A2:2014, EN 1990:2002+A1:2005
    • FRP Flexural Strengthening

      Concrete

      Externally bonded FRP (carbon, glass or aramid; fabric or pre-cured laminate) on the soffit of an existing reinforced concrete beam or slab strip: ACI PRC-440.2-17 Chapter 10 with debonding, the initial strain at installation, the strengthening limit, service

      • US ACI PRC-440.2-17, ACI CODE-318-19
    • Flag

      Wind actions

      Wind drag on a flag/banner and pole base moment: flag mass, shape, height and length.

      • AS/NZ AS/NZS 1170.2:2021
      • US ASCE/SEI 7-22
      • CA NBC 2020
      • EU EN 1991-1-4:2005+A1:2010
    • Flat Slab

      Concrete

      Flat slab (column-supported, no beams) by the Direct Design Method: the total static moment per panel, its negative/positive split, the column-strip and middle-strip distribution in both directions, and the top and bottom reinforcement (bar diameter and spacin

      • AS/NZ AS 3600:2018
      • US ACI CODE-318-25
      • CA CSA A23.3-19
      • EU EN 1992-1-1:2004+A1:2014
    • Flexure Member

      Concrete

      Rectangular, T- and L-beam flexure to AS 3600: bar-by-bar reinforcement (number and size), with the section classified balanced / under- / over-reinforced, a tension-steel yielding check, minimum and maximum steel, optional compression steel (doubly-reinforced

      • AS/NZ AS 3600:2018
      • US ACI CODE-318-25
      • CA CSA A23.3-19
      • EU EN 1992-1-1:2004+A1:2014
    • Floor Beam

      Steel members

      Simply-supported steel floor beam to AS 4100: factored UDL and midspan point load, section and member (lateral-torsional) moment, shear, and the floor deflection limits (live ≤ span/360, total ≤ span/250).

      • AS/NZ AS 4100:2020
      • US ANSI/AISC 360-22
      • CA CSA S16-19
      • EU EN 1993-1-1:2005+A1:2014, EN 1990:2002+A1:2005
    • Free Roof / Canopy

      Wind actions

      Net wind pressure and uplift on a free/canopy roof: canopy & average height, width, length, blocked underneath, enclosed sides and roof area.

      • AS/NZ AS/NZS 1170.2:2021
      • US ASCE/SEI 7-22
      • CA NBC 2020
      • EU EN 1991-1-4:2005+A1:2010
    • Hoarding

      Wind actions

      Solid hoarding / freestanding wall: drag force and base overturning moment per panel.

      • AS/NZ AS/NZS 1170.2:2021
      • US ASCE/SEI 7-22
      • CA NBC 2020
      • EU EN 1991-1-4:2005+A1:2010
    • Industrial Slab

      Retaining walls and slabs

      Industrial slab-on-grade under a concentrated (wheel/post) load: the radius of relative stiffness and the Westergaard interior and edge flexural stresses, checked against the allowable concrete flexural strength.

      • AS/NZ AS 3600:2018
      • US ACI 360R-10, ACI CODE-318-25
      • CA CSA A23.3-19
      • EU EN 1992-1-1:2004+A1:2014, Concrete Society TR34
    • Joint

      Timber

      Timber joint (bolted / nailed / screwed) lateral capacity to AS 1720.1 §4: the design capacity from the characteristic fastener capacity, the number of fasteners and the modification factors, checked against the design action.

      • AS/NZ AS 1720.1:2010
      • US ANSI/AWC NDS-2018
      • CA CSA O86-19
      • EU EN 1995-1-1:2004+A2:2014
    • Load Stiffener

      Steel members

      Load-bearing web stiffener to AS 4100 §5.14: a pair (or pairs) of stiffeners at a bearing/point load: the bearing-yield capacity and the buckling capacity of the stiffener-plus-web strut are checked against the applied reaction.

      • AS/NZ AS 4100:2020
      • US ANSI/AISC 360-22
      • CA CSA S16-19
      • EU EN 1993-1-1:2005+A1:2014, EN 1990:2002+A1:2005, EN 1993-1-5:2006
    • Masonry Member

      Masonry

      Unreinforced masonry wall/member in vertical compression to AS 3700: the characteristic compressive strength from the unit strength and mortar factor, the slenderness reduction, and the design compression capacity.

      • AS/NZ AS 3700:2018
      • US TMS 402-22
      • CA CSA S304-14
      • EU EN 1996-1-1:2005+A1:2012
    • Masonry Pier

      Masonry

      Masonry pier in compression to AS 3700: the same §7.3 compression model applied to an isolated pier (engaged or freestanding) carrying a concentrated load, with the slenderness reduction.

      • AS/NZ AS 3700:2018
      • US TMS 402-22
      • CA CSA S304-14
      • EU EN 1996-1-1:2005+A1:2012
    • Monoslope Roof

      Wind actions

      Wind pressures on a monoslope (skillion) roof to AS 1170.2 §5.4: the external pressure coefficients for the upwind/downwind slopes combined with the internal pressure give the net uplift and downward design pressures.

      • AS/NZ AS/NZS 1170.2:2021
      • US ASCE/SEI 7-22
      • CA NBC 2020
      • EU EN 1991-1-4:2005+A1:2010
    • Mullion

      Steel members

      Steel wall mullion / wind post to AS 4100: a vertical member spanning between floors under lateral wind pressure on its tributary width; checks bending, shear and the (governing) wind deflection.

      • AS/NZ AS 4100:2020
      • US ANSI/AISC 360-22
      • CA CSA S16-19
      • EU EN 1993-1-1:2005+A1:2014, EN 1990:2002+A1:2005, EN 1991-1-4:2005+A1:2010
    • One-Way Slab

      Concrete

      One-way reinforced-concrete slab to AS 3600: user-input bar diameter and spacing for the bottom (sag), top (hog) and secondary layers, with factored and service loads; flexure, one-way shear, service deflection, minimum reinforcement and crack-control checks.

      • AS/NZ AS 3600:2018
      • US ACI CODE-318-25
      • CA CSA A23.3-19
      • EU EN 1992-1-1:2004+A1:2014
    • PFC & Plate

      Steel members

      Built-up beam from a PFC (parallel-flange channel) with a welded plate: the combined section properties (about the composite neutral axis) and the section moment and shear capacities to AS 4100.

      • AS/NZ AS 4100:2020
      • US ANSI/AISC 360-22
      • CA CSA S16-19
      • EU EN 1993-1-1:2005+A1:2014, EN 1993-1-8:2005
    • Pad Foundation

      Footings

      Factored loading with eccentricity, uplift, sliding and overturning; two-way reinforcement by mesh (SL/RL) or bar diameter + spacing.

      • AS/NZ AS 3600:2018, AS 2159:2009
      • US ACI CODE-318-25
      • CA CSA A23.3-19
      • EU EN 1997-1:2004+A1:2013, EN 1992-1-1:2004+A1:2014, EN 1990:2002+A1:2005
    • Piered Beam

      Footings

      Reinforced-concrete ground beam spanning between bored piers: the wall/structure line load gives the span moment and shear; the RC section is checked for flexure, minimum steel, shear and deflection.

      • AS/NZ AS 3600:2018
      • US ACI CODE-318-25
      • CA CSA A23.3-19
      • EU EN 1997-1:2004+A1:2013, EN 1992-1-1:2004+A1:2014, EN 1990:2002+A1:2005
    • Pins

      Steel connections

      Pin connection to AS 4100 §9.4: the pin in shear (one or more shear planes), bearing between the pin and the connected plies, and pin bending from the ply spacing.

      • AS/NZ AS 4100:2020
      • US ANSI/AISC 360-22
      • CA CSA S16-19
      • EU EN 1993-1-8:2005
    • Plain Concrete

      Concrete

      Plain (unreinforced) concrete member to AS 3600 §20, a rectangular member of width b, depth D and bearing length L set by the user.

      • AS/NZ AS 3600:2018
      • US ACI CODE-318-25
      • CA CSA A23.3-19
      • EU EN 1992-1-1:2004+A1:2014
    • Portal Frame

      Steel members

      Single-bay portal frame to AS 4100: the gravity and wind load cases give the knee and apex moments; the rafter and column (as beam-columns) are checked against their member moment capacities at the critical knee.

      • AS/NZ AS 4100:2020
      • US ANSI/AISC 360-22
      • CA CSA S16-19
      • EU EN 1993-1-1:2005+A1:2014, EN 1990:2002+A1:2005
    • Portal Knee

      Steel connections

      Bolted moment end-plate at a portal-frame knee: the rafter/column moment and shear are resisted by the tension-bolt group, the end-plate in bending and the welds; capacities are checked against the knee actions.

      • AS/NZ AS 4100:2020
      • US ANSI/AISC 360-22
      • CA CSA S16-19
      • EU EN 1993-1-8:2005, EN 1993-1-1:2005+A1:2014
    • Post Footing

      Footings

      Embedded post footing driven by lateral load, applied moment, load height, footing width/depth and soil φ/γ (embedment depth governs).

      • US IBC 2018
      • CA NBC 2020
      • EU EN 1997-1:2004+A1:2013
    • Propped Beam

      Steel members

      Steel propped cantilever to AS 4100: UDL with the fixed-end (hogging) and span (sagging) moments, the wall and prop reactions, the maximum shear at the fixed end, and the deflection limit.

      • AS/NZ AS 4100:2020
      • US ANSI/AISC 360-22
      • CA CSA S16-19
      • EU EN 1993-1-1:2005+A1:2014, EN 1990:2002+A1:2005
    • Punching Shear

      Concrete

      Two-way (punching) shear at a slab-column connection to AS 3600 §9.3: circular or rectangular column, interior/edge/corner case, unbalanced-moment transfer, and shear-reinforcement / integrity check.

      • AS/NZ AS 3600:2018
      • US ACI CODE-318-25
      • CA CSA A23.3-19
      • EU EN 1992-1-1:2004+A1:2014
    • Purlin & Girt Loads

      Wind actions

      Purlin/girt member under wind to AS 4100: the wind line load over the member spacing gives the span moment, shear and deflection, checked against the section/member capacities (single or lapped/continuous).

      • AS/NZ AS 4100:2020
      • US ASCE/SEI 7-22, ANSI/AISC 360-22
      • CA NBC 2020, CSA S16-19
      • EU EN 1991-1-4:2005+A1:2010, EN 1993-1-1:2005+A1:2014
    • Rainfall Intensity (AEP)

      Drainage

      Design rainfall intensity expressed in the modern annual-exceedance-probability (AEP) frequency descriptor: converts the AEP to an equivalent ARI and returns the IFD intensity and optional peak flow.

      • AS/NZ ARR 2019, AS/NZS 3500.3
      • US NOAA Atlas 14, IPC 2018, ASCE/SEI 7-22
      • CA NBC 2020, NPC 2020
      • EU EN 12056-3, EN 752
    • Rainfall Intensity (ARI)

      Drainage

      Design rainfall intensity for a chosen average recurrence interval (ARI) and storm duration from the site IFD coefficients, with the equivalent AEP and an optional Rational-Method peak flow.

      • AS/NZ AS/NZS 3500.3
      • US NOAA Atlas 14, IPC 2018, ASCE/SEI 7-22
      • CA NBC 2020, NPC 2020
      • EU EN 12056-3, EN 752
    • Reinforcement Table

      Concrete

      Reinforcement quantity reference: bar area, number of bars per metre and steel area for a chosen bar diameter and spacing (or count over a width), with a quick area-per-metre lookup grid.

      • AS/NZ AS 3600:2018
      • US ACI CODE-318-25
      • CA CSA A23.3-19, CSA G30.18
      • EU EN 1992-1-1:2004+A1:2014, EN 10080
    • Residential Slab

      Retaining walls and slabs

      Stiffened-raft / waffle footing screening to AS 2870: for the site class and construction type it gives the deemed-to-comply stiffening-beam depth and maximum beam spacing (Table 3.1) and checks the provided raft against them.

      • AS/NZ AS 2870:2011
      • US IBC 2018, IRC 2018, ACI CODE-318-25
      • CA NBC 2020, CSA A23.1-19, CSA A23.3-19
      • EU EN 1992-1-1:2004+A1:2014, EN 1997-1:2004+A1:2013, EN 1990:2002+A1:2005
    • Retaining Wall

      Retaining walls and slabs

      Generic cantilever retaining wall: toe and heel, base thickness, optional shear key and drained/undrained (water table) condition; stem BMD/SFD, overturning, sliding (incl.

      • AS/NZ AS 4678:2002, AS 3600:2018
      • US ACI CODE-318-25
      • CA CSA A23.3-19
      • EU EN 1997-1:2004+A1:2013, EN 1992-1-1:2004+A1:2014
    • Roof Beam

      Steel members

      Steel roof beam/rafter to AS 4100: gravity (1.2G + 1.5Q) and net wind-uplift (0.9G + Wu) load cases, section and member moment, shear, and the imposed/wind deflection limits.

      • AS/NZ AS 4100:2020
      • US ANSI/AISC 360-22
      • CA CSA S16-19
      • EU EN 1993-1-1:2005+A1:2014, EN 1990:2002+A1:2005
    • Section Properties

      Analysis

      Section property calculator: looks up a hot-rolled library section (area, second moments, section/plastic moduli, radii of gyration, mass) or computes the properties of a custom rectangular, circular or I-shape from first principles.

      • AS/NZ AS/NZS 3679.1
    • Shelf Angle

      Steel members

      Shelf angle / masonry support angle to AS 4100: the eccentric brick load bends the angle leg; the leg bending capacity and the fixing-bolt shear back to the structure are checked per metre.

      • AS/NZ AS 4100:2020
      • US ANSI/AISC 360-22
      • CA CSA S16-19
      • EU EN 1993-1-1:2005+A1:2014, EN 1993-1-8:2005
    • Sleeper Wall

      Retaining walls and slabs

      Sleeper wall: steel posts embedded in soil, with timber or concrete sleeper planks spanning horizontally between posts.

      • AS/NZ AS 4678:2002
      • US IBC 2018, ANSI/AWC NDS-2018, ANSI/AISC 360-22
      • CA NBC 2020, CSA O86-19, CSA S16-19
      • EU EN 1997-1:2004+A1:2013, EN 1993-1-1:2005+A1:2014, EN 1995-1-1:2004+A2:2014
    • Snow Loads

      Snow actions

      Roof snow load s = s_g·C_e·μ_i to AS/NZS 1170.3:2003 for mono-pitched and duo-pitched roofs, obstructed roofs and lower roofs beside a step, with the ground snow load s_g from the snow region and the elevation (Section 5), the alpine or sub-alpine shape coeffi

      • AS/NZ AS/NZS 1170.3:2003
      • US ASCE/SEI 7-22
      • CA NBC 2020
      • EU EN 1991-1-3:2003+A1:2015
    • Stair

      Concrete

      RC stair flight (waist slab): the dead load of the inclined waist and steps plus the live load, the span moment and shear, the flexural reinforcement and the span/depth serviceability check.

      • AS/NZ AS 3600:2018
      • US ACI CODE-318-25
      • CA CSA A23.3-19
      • EU EN 1992-1-1:2004+A1:2014
    • Static Analysis

      Earthquake actions

      Equivalent static earthquake analysis to AS 1170.4: the spectral shape factor, the horizontal design coefficient, the base shear and its vertical distribution up the height of a regular building.

      • AS/NZ AS 1170.4:2007
      • US ASCE/SEI 7-22
      • CA NBC 2020
      • EU EN 1998-1:2004+A1:2013
    • Steel Column

      Steel members

      Axially-loaded steel column to AS 4100 §6: section capacity (yield), member capacity (flexural buckling) with user-selected end fixity per axis (Le = ke·L), and the slenderness limit.

      • AS/NZ AS 4100:2020
      • US ANSI/AISC 360-22
      • CA CSA S16-19
      • EU EN 1993-1-1:2005+A1:2014, EN 1990:2002+A1:2005
    • Steel Member

      Steel members

      Hot-rolled steel member (UB / UC / PFC / TFB) to AS 4100: section moment, member lateral-torsional buckling, shear and section compression.

      • AS/NZ AS 4100:2020
      • US ANSI/AISC 360-22
      • CA CSA S16-19
      • EU EN 1993-1-1:2005+A1:2014, EN 1990:2002+A1:2005
    • Steel Member in Fire

      Fire design

      Fire resistance of a steel beam or column to AS 4100:2020 Section 12: exposed surface area to mass ratio k_sm for three or four sided exposure, limiting temperature T_l = 905 - 690r_f, time to reach T_l for an unprotected member (Cl.

      • AS/NZ AS 4100:2020
      • US ANSI/AISC 360-22
      • CA CSA S16-19
      • EU EN 1993-1-2:2005
    • Stormwater Detention

      Drainage

      On-site stormwater detention (OSD): the pre- and post-development peak flows, the required detention storage volume and the orifice size to throttle the outflow to the permitted site-discharge.

      • AS/NZ AS/NZS 3500
      • EU EN 752
    • Strip Footing

      Footings

      Continuous strip footing under a wall line-load: bearing pressure, the cantilever face moment and reinforcement, and one-way shear, all per metre run.

      • AS/NZ AS 3600:2018
      • US ACI CODE-318-25
      • CA CSA A23.3-19
      • EU EN 1997-1:2004+A1:2013, EN 1992-1-1:2004+A1:2014, EN 1990:2002+A1:2005
    • Strut & Tie

      Concrete

      Strut-and-tie model for a concrete D-region / deep beam to AS 3600 §7: strut efficiency factor βs, diagonal-strut and bottom-tie capacities, node bearing, the diagonal-compression limit, and tie reinforcement (bar diameter and number).

      • AS/NZ AS 3600:2018
      • US ACI CODE-318-25
      • CA CSA A23.3-19
      • EU EN 1992-1-1:2004+A1:2014
    • Symbols

      Utilities

      Notation and symbol reference: the common symbols used across the Australian Standards (general, actions, concrete, steel, timber, masonry, geotechnical) with their meaning and source standard.

      • T / Angle Lintel

        Steel members

        Steel lintel (angle, PFC or flat) over a masonry opening: masonry arching (triangular) load to AS 3700, bending and deflection to AS 4100, and support bearing.

        • AS/NZ AS 4100:2020, AS 3700:2018
        • US ANSI/AISC 360-22
        • CA CSA S16-19
        • EU EN 1993-1-1:2005+A1:2014, EN 1996-1-1:2005+A1:2012
      • Taper Haunch

        Steel connections

        Tapered haunch at a portal-frame knee: the deepened (haunched) section at the knee and the rafter section at the haunch toe are checked for moment, with the lateral-torsional capacity of the unrestrained inner (compression) flange over the haunch length, plus

        • AS/NZ AS 4100:2020
        • US ANSI/AISC 360-22
        • CA CSA S16-19
        • EU EN 1993-1-1:2005+A1:2014
      • Tension Member

        Steel members

        Axially-loaded steel tension member to AS 4100 §7.2: gross-section yield and net-section fracture, including the end-connection eccentricity factor kt and net-area (bolt-hole) reduction.

        • AS/NZ AS 4100:2020
        • US ANSI/AISC 360-22
        • CA CSA S16-19
        • EU EN 1993-1-1:2005+A1:2014, EN 1990:2002+A1:2005, EN 1993-1-8:2005
      • Terrain Change

        Wind actions

        Wind terrain/height multiplier with a terrain-category change to AS 1170.2 §4.2: the lag-distance interpolation between the upwind and downwind categories gives the governing M_z,cat, the design wind speed and the dynamic pressure.

        • AS/NZ AS/NZS 1170.2:2021
        • US ASCE/SEI 7-22
        • CA NBC 2020
        • EU EN 1991-1-4:2005+A1:2010
      • Timber Column

        Timber

        Timber column/post to AS 1720.1 §3.3: axial compression with the slenderness stability factor k12 about both axes; the worse axis governs.

        • AS/NZ AS 1720.1:2010
        • US ANSI/AWC NDS-2018
        • CA CSA O86-19
        • EU EN 1995-1-1:2004+A2:2014, EN 1990:2002+A1:2005
      • Timber Floor Beam

        Timber

        Sawn/LVL timber floor beam to AS 1720.1: bending with lateral-stability k12, shear, and the creep-affected total deflection plus the live-load deflection.

        • AS/NZ AS 1720.1:2010
        • US ANSI/AWC NDS-2018
        • CA CSA O86-19
        • EU EN 1995-1-1:2004+A2:2014, EN 1990:2002+A1:2005
      • Timber Member

        Timber

        Sawn / glulam rectangular timber member to AS 1720.1: bending, shear, compression, tension and combined actions, with the k-factor capacity model and slenderness (k12) stability.

        • AS/NZ AS 1720.1:2010
        • US ANSI/AWC NDS-2018
        • CA CSA O86-19
        • EU EN 1995-1-1:2004+A2:2014, EN 1990:2002+A1:2005
      • Timber Member in Fire

        Fire design

        Fire resistance of a timber beam or column to AS 1720.4 by the residual section method: char rate from the timber density or Table 2.5.1, the 7.0 mm uncharred layer of Eq 2.6.1, residual section, and the bending, shear or compression capacity of the residual s

        • AS/NZ AS 1720.4:2019
        • US ANSI/AWC NDS-2018
        • CA CSA O86-19
        • EU EN 1995-1-2:2004
      • Timber Roof Beam

        Timber

        Timber roof beam/rafter to AS 1720.1: gravity (G + Q) and wind (including net uplift) load cases, bending with k12, shear, and deflection.

        • AS/NZ AS 1720.1:2010
        • US ANSI/AWC NDS-2018
        • CA CSA O86-19
        • EU EN 1995-1-1:2004+A2:2014, EN 1990:2002+A1:2005
      • Tree Effects: Piers

        Footings

        Bored pier through a tree-affected reactive (drying/swelling) zone: checks the uplift on the shaft from the reactive soil against the structure dead load plus the anchorage below the active zone, and the minimum embedment below that zone.

        • AS/NZ AS 2870:2011, AS 2159:2009
      • Tree Effects: y_s

        Retaining walls and slabs

        Characteristic surface movement y_s and AS 2870 site classification, including the effect of nearby trees that dry the soil more deeply: the instability index, design suction change and depth of suction change give y_s, which trees increase by extending the ac

        • AS/NZ AS 2870:2011
      • Two-Way Slab

        Concrete

        Two-way spanning slab supported on four edges: the Grashof load share between the short and long spans, the positive span moments (and support hogging if continuous), reinforcement each way and the span/depth deflection control.

        • AS/NZ AS 3600:2018
        • US ACI CODE-318-25
        • CA CSA A23.3-19
        • EU EN 1992-1-1:2004+A1:2014
      • Unit Conversions

        Utilities

        Engineering unit converter: enter a value in the SI base unit of a quantity (force, stress, moment, length, line load or area) and read it in all the common alternative units.

        • Web Bearing

          Steel members

          Steel web bearing under a concentrated load/reaction to AS 4100 §5.13: bearing yield and bearing buckling (web as a column), with the 1:2.5 flange dispersion and the interior/end stiff-bearing condition.

          • AS/NZ AS 4100:2020
          • US ANSI/AISC 360-22
          • CA CSA S16-19
          • EU EN 1993-1-1:2005+A1:2014, EN 1990:2002+A1:2005, EN 1993-1-5:2006
        • Weld Group

          Steel members

          Fillet weld group under in-plane eccentric shear to AS 4100 §9.7: the welds are treated as unit-throat line elements; the direct shear and the torsional shear from the eccentric moment are combined at the critical point and checked against the per-length capac

          • AS/NZ AS 4100:2020
          • US ANSI/AISC 360-22
          • CA CSA S16-19
          • EU EN 1993-1-8:2005
        • Welds

          Steel connections

          Fillet weld capacity to AS 4100 §9.7.3: design throat from the leg size, the capacity per unit length for the electrode and weld category (SP/GP), and the check against the resultant design force per unit length.

          • AS/NZ AS 4100:2020
          • US ANSI/AISC 360-22
          • CA CSA S16-19
          • EU EN 1993-1-8:2005
        • Wind Actions

          Wind actions

          Site wind speed and design pressures with importance level, design life, roof pitch, average/roof height, blocked-underneath internal pressure and area-reduction Ka.

          • AS/NZ AS/NZS 1170.2:2021
          • US ASCE/SEI 7-22
          • CA NBC 2020
          • EU EN 1991-1-4:2005+A1:2010

        Aluminium and bridge design modules are not part of TensorNode yet. Aluminium and prestressing materials can be used in the FEA Tool and the section designer. Modules for each code system are listed on the design codes page.

        Open TensorNode