TensorNodeStart free trial
Home / Products / Foundation design / Industrial Slab

Industrial Slab design check for AS 3600, ACI 360R, CSA A23.3 and Eurocode 2

Industrial slab-on-grade under a concentrated (wheel/post) load.

Create a free account to use it

7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.

What it checks

The radius of relative stiffness and the Westergaard interior and edge flexural stresses, checked against the allowable concrete flexural strength.

Inputs

Industrial Slab takes 7 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.

InputUnitDefault
Load
Concentrated load PkN30
Contact radius amm150
Slab
Slab thickness hmm200
Subgrade
Subgrade modulus kN/mm³0.04
Material
Concrete f'cMPa32
Concrete EMPa30000
Design
Factor of safety-1.8

Results and report

The module reports: Radius of relative stiffness ℓ; Equivalent radius b; Interior stress σi; Edge stress σe; Allowable stress.

It checks: Interior-load flexural stress; Edge-load flexural stress; Radius of relative stiffness.

Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.

Example with the default inputs

Industrial Slab with its default inputs for the Australia and New Zealand code system. The main inputs:

InputValue
Concentrated load P30 kN
Contact radius a150 mm
Slab thickness h200 mm
Subgrade modulus k0.04 N/mm³
Concrete f'c32 MPa
Concrete E30000 MPa
Factor of safety1.8

Headline results:

ResultValue
Radius of relative stiffness ℓ846 mm
Equivalent radius b141 mm
Interior stress σi0.99 MPa
Edge stress σe1.49 MPa
Allowable stress1.89 (f'ct.f 3.39) MPa

Governing check: Edge-load flexural stress (Westergaard), σ_e 1.49 MPa against allow 1.89 MPa, utilisation 0.79, passes.

Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.

Design codes

Industrial Slab works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.

RegionStandard and edition
Australia and New ZealandAS 3600:2018
United StatesACI 360R-10, ACI CODE-318-25
CanadaCSA A23.3-19
EuropeEN 1992-1-1:2004+A1:2014, Concrete Society TR34

Use it in full during the 7-day trial of the Professional plan. Paid plans give access to the module packs. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.

Related modules

All foundation design modules

Open Industrial Slab with a free account

7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.