Structural loads calculator for AS/NZS 1170.2, ASCE 7, NBC 2020 and Eurocode 1
TensorNode has 11 structural loads modules for Australia and New Zealand, United States, Canada and Europe. Wind, snow and earthquake actions, dead and live loads and the load combinations that feed the design modules.
Create a free account to use it
7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.
Codes and editions
The standards below are the ones the structural loads modules use, by region and with the edition each module implements. The count is the number of modules that use the standard.
| Region | Standard and edition | Modules | Used by |
|---|---|---|---|
| Australia and New Zealand | AS/NZS 1170.2:2021 | 6 | Flag, Free Roof / Canopy, Hoarding, Monoslope Roof, Terrain Change and 1 more |
| Australia and New Zealand | AS 1170.4:2007 | 2 | Earthquake Design Category, Static Analysis |
| Australia and New Zealand | AS 4100:2020 | 1 | Purlin & Girt Loads |
| Australia and New Zealand | AS/NZS 1170.1:2002 | 1 | Dead & Live Loads |
| Australia and New Zealand | AS/NZS 1170.3:2003 | 1 | Snow Loads |
| United States | ASCE/SEI 7-22 | 11 | Dead & Live Loads, Earthquake Design Category, Flag, Free Roof / Canopy, Hoarding and 6 more |
| United States | ANSI/AISC 360-22 | 1 | Purlin & Girt Loads |
| Canada | NBC 2020 | 11 | Dead & Live Loads, Earthquake Design Category, Flag, Free Roof / Canopy, Hoarding and 6 more |
| Canada | CSA S16-19 | 1 | Purlin & Girt Loads |
| Europe | EN 1991-1-4:2005+A1:2010 | 7 | Flag, Free Roof / Canopy, Hoarding, Monoslope Roof, Purlin & Girt Loads and 2 more |
| Europe | EN 1998-1:2004+A1:2013 | 2 | Earthquake Design Category, Static Analysis |
| Europe | EN 1990:2002+A1:2005 | 1 | Dead & Live Loads |
| Europe | EN 1991-1-3:2003+A1:2015 | 1 | Snow Loads |
| Europe | EN 1993-1-1:2005+A1:2014 | 1 | Purlin & Girt Loads |
What each module checks
Each name opens the page of that module, with what it checks, the standards it works to and the related modules.
Dead and live loads
- Dead & Live Loads
Load takedown
Earthquake actions
- Earthquake Design Category
Earthquake Design Category (EDC) determination to AS 1170.4 §2 - Static Analysis
Equivalent static earthquake analysis to AS 1170.4
Wind actions
- Flag
Wind drag on a flag/banner and pole base moment: flag mass, shape, height and length. - Free Roof / Canopy
Net wind pressure and uplift on a free/canopy roof - Hoarding
Solid hoarding / freestanding wall: drag force and base overturning moment per panel. - Monoslope Roof
Wind pressures on a monoslope (skillion) roof to AS 1170.2 §5.4 - Purlin & Girt Loads
Purlin/girt member under wind to AS 4100 - Terrain Change
Wind terrain/height multiplier with a terrain-category change to AS 1170.2 §4.2 - Wind Actions
Site wind speed and design pressures with importance level, design life, roof pitch, average/roof height,...
Snow actions
- Snow Loads
Roof snow load s = s_g·C_e·μ_i to AS/NZS 1170.3:2003 for mono-pitched and duo-pitched roofs, obstructed roofs and...
Report for every check
Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.
Try it
Create a free account to use the modules: 7 days of the Professional plan, no card. 3 of the 11 modules above are among the basic calculators of the Free plan, which you keep after the trial. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design.
Questions
Which codes do the structural loads modules cover?
The 11 modules work to AS/NZS 1170.2, ASCE 7, NBC 2020 and Eurocode 1. Editions: Australia and New Zealand: AS/NZS 1170.2:2021, AS 4100:2020, AS/NZS 1170.3:2003, AS/NZS 1170.1:2002 and 1 more; United States: ASCE/SEI 7-22, ANSI/AISC 360-22; Canada: NBC 2020, CSA S16-19; Europe: EN 1991-1-4:2005+A1:2010, EN 1993-1-1:2005+A1:2014, EN 1991-1-3:2003+A1:2015, EN 1990:2002+A1:2005 and 1 more. Pick the code system once and every module follows it.
Which regions are covered?
Australia and New Zealand, United States, Canada and Europe. 11 of the 11 modules work to all four code systems.
Can I try them without a card?
Yes. Create an account with your email and a password: you get 7 days of the Professional plan with no card. After that the account moves to the Free plan and nothing is charged automatically. 3 of these 11 modules are among the basic calculators of the Free plan.
Does TensorNode include the text of the standards?
Standards are cited by number and edition only. TensorNode does not reproduce the text of any standard; keep your own current copy.
Who checks the results?
TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design.
Create a free account to use it
7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.