TensorNodeStart free trial
Home / Products / Wind loads / Purlin & Girt Loads

Purlin & Girt Loads calculator for AS 4100, ASCE 7, NBC 2020 and Eurocode 1

Purlin/girt member under wind to AS 4100.

Create a free account to use it

7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.

What it checks

The wind line load over the member spacing gives the span moment, shear and deflection, checked against the section/member capacities (single or lapped/continuous).

Clauses and parts as listed in the module: US: ASCE/SEI 7-22 Ch. 30 Part 1, AISC 360-22; CA: NBC 2020 4.1.7, CSA S16-19.

Inputs

Purlin & Girt Loads takes 6 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.

InputUnitDefault
Geometry
Spanm6
Member spacingm1.2
Lapped / continuous-No
Section
Section type-PFC
Section Options: 150PFC17.7; 180PFC20.9; 200PFC22.9; 250PFC35.5.-150PFC17.7
Loads
Net wind pressurekPa1

Results and report

The module reports: Section; Line load w; Moment M*; Shear V*; Deflection.

It checks: Bending (wind); Deflection (W).

Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.

Example with the default inputs

Purlin & Girt Loads with its default inputs for the Australia and New Zealand code system. The main inputs:

InputValue
Span6 m
Member spacing1.2 m
Lapped / continuousNo
Section typePFC
Section150PFC17.7
Net wind pressure1 kPa

Headline results:

ResultValue
Section150PFC17.7
Line load w1.20 kN/m
Moment M*5.4 (φMbx 12.8) kNm
Shear V*3.6 (φVv 155.5) kN
Deflection12.1 (span/150 40.0) mm

Governing check: Bending (wind) (AS 4100 §5.2/§5.6), M* 5.4 kNm against φMbx 12.8 kNm, utilisation 0.42, passes.

Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.

Design codes

Purlin & Girt Loads works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.

RegionStandard and edition
Australia and New ZealandAS 4100:2020
United StatesASCE/SEI 7-22, ANSI/AISC 360-22
CanadaNBC 2020, CSA S16-19
EuropeEN 1991-1-4:2005+A1:2010, EN 1993-1-1:2005+A1:2014

Use it in full during the 7-day trial of the Professional plan. Paid plans give access to the module packs. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.

Related modules

  • Flag
    Wind drag on a flag/banner and pole base moment
  • Free Roof / Canopy
    Net wind pressure and uplift on a free/canopy roof
  • Hoarding
    Solid hoarding / freestanding wall
  • Monoslope Roof
    Wind pressures on a monoslope (skillion) roof to AS 1170.2 §5.4
  • Terrain Change
    Wind terrain/height multiplier with a terrain-category change to AS 1170.2 §4.2
  • Wind Actions
    Site wind speed and design pressures with importance level, design life, roof pitch, average/roof height, blocked-underneath internal pressure and area-reduction Ka.

All wind loads modules

Open Purlin & Girt Loads with a free account

7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.