Purlin & Girt Loads calculator for AS 4100, ASCE 7, NBC 2020 and Eurocode 1
Purlin/girt member under wind to AS 4100.
Create a free account to use it
7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.
What it checks
The wind line load over the member spacing gives the span moment, shear and deflection, checked against the section/member capacities (single or lapped/continuous).
Clauses and parts as listed in the module: US: ASCE/SEI 7-22 Ch. 30 Part 1, AISC 360-22; CA: NBC 2020 4.1.7, CSA S16-19.
Inputs
Purlin & Girt Loads takes 6 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.
| Input | Unit | Default |
|---|---|---|
| Geometry | ||
| Span | m | 6 |
| Member spacing | m | 1.2 |
| Lapped / continuous | - | No |
| Section | ||
| Section type | - | PFC |
| Section Options: 150PFC17.7; 180PFC20.9; 200PFC22.9; 250PFC35.5. | - | 150PFC17.7 |
| Loads | ||
| Net wind pressure | kPa | 1 |
Results and report
The module reports: Section; Line load w; Moment M*; Shear V*; Deflection.
It checks: Bending (wind); Deflection (W).
Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.
Example with the default inputs
Purlin & Girt Loads with its default inputs for the Australia and New Zealand code system. The main inputs:
| Input | Value |
|---|---|
| Span | 6 m |
| Member spacing | 1.2 m |
| Lapped / continuous | No |
| Section type | PFC |
| Section | 150PFC17.7 |
| Net wind pressure | 1 kPa |
Headline results:
| Result | Value |
|---|---|
| Section | 150PFC17.7 |
| Line load w | 1.20 kN/m |
| Moment M* | 5.4 (φMbx 12.8) kNm |
| Shear V* | 3.6 (φVv 155.5) kN |
| Deflection | 12.1 (span/150 40.0) mm |
Governing check: Bending (wind) (AS 4100 §5.2/§5.6), M* 5.4 kNm against φMbx 12.8 kNm, utilisation 0.42, passes.
Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.
Design codes
Purlin & Girt Loads works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.
| Region | Standard and edition |
|---|---|
| Australia and New Zealand | AS 4100:2020 |
| United States | ASCE/SEI 7-22, ANSI/AISC 360-22 |
| Canada | NBC 2020, CSA S16-19 |
| Europe | EN 1991-1-4:2005+A1:2010, EN 1993-1-1:2005+A1:2014 |
Use it in full during the 7-day trial of the Professional plan. Paid plans give access to the module packs. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.
Related modules
- Flag
Wind drag on a flag/banner and pole base moment - Free Roof / Canopy
Net wind pressure and uplift on a free/canopy roof - Hoarding
Solid hoarding / freestanding wall - Monoslope Roof
Wind pressures on a monoslope (skillion) roof to AS 1170.2 §5.4 - Terrain Change
Wind terrain/height multiplier with a terrain-category change to AS 1170.2 §4.2 - Wind Actions
Site wind speed and design pressures with importance level, design life, roof pitch, average/roof height, blocked-underneath internal pressure and area-reduction Ka.
Open Purlin & Girt Loads with a free account
7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.