Monoslope Roof calculator for AS/NZS 1170.2, ASCE 7, NBC 2020 and Eurocode 1
Wind pressures on a monoslope (skillion) roof to AS 1170.2 §5.4.
Create a free account to use it
7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.
What it checks
The external pressure coefficients for the upwind/downwind slopes combined with the internal pressure give the net uplift and downward design pressures.
Clauses and parts as listed in the module: CA: NBC 2020 4.1.7.
Inputs
Monoslope Roof takes 6 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.
| Input | Unit | Default |
|---|---|---|
| Site | ||
| Wind region Options: A; B; C; D. | - | A |
| Terrain category Options: TC1; TC2; TC3; TC4. | - | TC2 |
| Roof height z | m | 6 |
| Roof | ||
| Roof pitch | ° | 5 |
| Tributary area | m² | 25 |
| Openings Options: Nominally sealed; Dominant opening. | - | Nominally sealed |
Results and report
The module reports: Dynamic pressure q; Cpe (up / down); Internal Cpi; Net uplift; Net download.
It checks: Governing net pressure.
Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.
Example with the default inputs
Monoslope Roof with its default inputs for the Australia and New Zealand code system. The main inputs:
| Input | Value |
|---|---|
| Wind region | A |
| Terrain category | TC2 |
| Roof height z | 6 m |
| Roof pitch | 5 ° |
| Tributary area | 25 m² |
| Openings | Nominally sealed |
Headline results:
| Result | Value |
|---|---|
| Dynamic pressure q | 1.05 kPa |
| Cpe (up / down) | -0.90 / -0.40 |
| Internal Cpi | -0.30 |
| Net uplift | -0.53 kPa |
| Net download | -0.06 kPa |
Governing check: Down pressure (leeward, Cpe -0.40) (AS 1170.2 §5.4.2), p_down = -0.06 kPa against Cpe·Ka = -0.360 Cpi = -0.30, utilisation 0.12, passes.
Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.
Design codes
Monoslope Roof works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.
| Region | Standard and edition |
|---|---|
| Australia and New Zealand | AS/NZS 1170.2:2021 |
| United States | ASCE/SEI 7-22 |
| Canada | NBC 2020 |
| Europe | EN 1991-1-4:2005+A1:2010 |
Use it in full during the 7-day trial of the Professional plan. Paid plans give access to the module packs. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.
Related modules
- Flag
Wind drag on a flag/banner and pole base moment - Free Roof / Canopy
Net wind pressure and uplift on a free/canopy roof - Hoarding
Solid hoarding / freestanding wall - Purlin & Girt Loads
Purlin/girt member under wind to AS 4100 - Terrain Change
Wind terrain/height multiplier with a terrain-category change to AS 1170.2 §4.2 - Wind Actions
Site wind speed and design pressures with importance level, design life, roof pitch, average/roof height, blocked-underneath internal pressure and area-reduction Ka.
Open Monoslope Roof with a free account
7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.