TensorNodeStart free trial
Home / Products / Wind loads / Monoslope Roof

Monoslope Roof calculator for AS/NZS 1170.2, ASCE 7, NBC 2020 and Eurocode 1

Wind pressures on a monoslope (skillion) roof to AS 1170.2 §5.4.

Create a free account to use it

7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.

What it checks

The external pressure coefficients for the upwind/downwind slopes combined with the internal pressure give the net uplift and downward design pressures.

Clauses and parts as listed in the module: CA: NBC 2020 4.1.7.

Inputs

Monoslope Roof takes 6 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.

InputUnitDefault
Site
Wind region Options: A; B; C; D.-A
Terrain category Options: TC1; TC2; TC3; TC4.-TC2
Roof height zm6
Roof
Roof pitch°5
Tributary aream²25
Openings Options: Nominally sealed; Dominant opening.-Nominally sealed

Results and report

The module reports: Dynamic pressure q; Cpe (up / down); Internal Cpi; Net uplift; Net download.

It checks: Governing net pressure.

Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.

Example with the default inputs

Monoslope Roof with its default inputs for the Australia and New Zealand code system. The main inputs:

InputValue
Wind regionA
Terrain categoryTC2
Roof height z6 m
Roof pitch5 °
Tributary area25 m²
OpeningsNominally sealed

Headline results:

ResultValue
Dynamic pressure q1.05 kPa
Cpe (up / down)-0.90 / -0.40
Internal Cpi-0.30
Net uplift-0.53 kPa
Net download-0.06 kPa

Governing check: Down pressure (leeward, Cpe -0.40) (AS 1170.2 §5.4.2), p_down = -0.06 kPa against Cpe·Ka = -0.360 Cpi = -0.30, utilisation 0.12, passes.

Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.

Design codes

Monoslope Roof works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.

RegionStandard and edition
Australia and New ZealandAS/NZS 1170.2:2021
United StatesASCE/SEI 7-22
CanadaNBC 2020
EuropeEN 1991-1-4:2005+A1:2010

Use it in full during the 7-day trial of the Professional plan. Paid plans give access to the module packs. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.

Related modules

  • Flag
    Wind drag on a flag/banner and pole base moment
  • Free Roof / Canopy
    Net wind pressure and uplift on a free/canopy roof
  • Hoarding
    Solid hoarding / freestanding wall
  • Purlin & Girt Loads
    Purlin/girt member under wind to AS 4100
  • Terrain Change
    Wind terrain/height multiplier with a terrain-category change to AS 1170.2 §4.2
  • Wind Actions
    Site wind speed and design pressures with importance level, design life, roof pitch, average/roof height, blocked-underneath internal pressure and area-reduction Ka.

All wind loads modules

Open Monoslope Roof with a free account

7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.