TensorNodeStart free trial
Home / Products / Wind loads / Free Roof / Canopy

Free Roof / Canopy calculator for AS/NZS 1170.2, ASCE 7, NBC 2020 and Eurocode 1

Net wind pressure and uplift on a free/canopy roof.

Create a free account to use it

7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.

What it checks

Canopy & average height, width, length, blocked underneath, enclosed sides and roof area.

Clauses and parts as listed in the module: AS/NZ: AS/NZS 1170.2:2021 §5.4; US: ASCE/SEI 7-22 27.3.2; CA: NBC 2020 4.1.7.

Inputs

Free Roof / Canopy takes 10 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.

InputUnitDefault
Wind
Vdes (m/s): enter directly OR set to 0 to compute from region/terrain belowm/s45
Wind region (used if Vdes=0) Options: -; A; B; C (cyclonic); D (cyclonic).--
Terrain category (used if Vdes=0) Options: TC1; TC2; TC3; TC4.-TC2
Geometry
Canopy heightm3
Canopy widthm6
Canopy lengthm12
Roof pitch°5
Roof area (0 = w×l)m²0
Underside blocked (any enclosed side): note: number of enclosed sides (1/2/3) has negligible separate impact per AS 1170.2 §5.4; the blocked flag captures the key effect-No
Enclosed sides (one or more enclosed sides is treated as a blocked underside) Options: 0; 1; 2; 3.-0

Results and report

The module reports: Free-stream q; Net Cp,net; Area-reduction Ka; Net pressure; Total uplift force.

Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.

Example with the default inputs

Free Roof / Canopy with its default inputs for the Australia and New Zealand code system. The main inputs:

InputValue
Vdes (m/s): enter directly OR set to 0 to compute from region/terrain below45 m/s
Wind region (used if Vdes=0)-
Terrain category (used if Vdes=0)TC2
Canopy height3 m
Canopy width6 m
Canopy length12 m
Roof pitch5 °
Roof area (0 = w×l)0 m²

Headline results:

ResultValue
Free-stream q1.22 kPa
Net Cp,net1.00
Area-reduction Ka0.84
Net pressure1.02 kPa
Total uplift force73.2 kN

Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.

Design codes

Free Roof / Canopy works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.

RegionStandard and edition
Australia and New ZealandAS/NZS 1170.2:2021
United StatesASCE/SEI 7-22
CanadaNBC 2020
EuropeEN 1991-1-4:2005+A1:2010

Use it in full during the 7-day trial of the Professional plan. Paid plans give access to the module packs. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.

Related modules

  • Flag
    Wind drag on a flag/banner and pole base moment
  • Hoarding
    Solid hoarding / freestanding wall
  • Monoslope Roof
    Wind pressures on a monoslope (skillion) roof to AS 1170.2 §5.4
  • Purlin & Girt Loads
    Purlin/girt member under wind to AS 4100
  • Terrain Change
    Wind terrain/height multiplier with a terrain-category change to AS 1170.2 §4.2
  • Wind Actions
    Site wind speed and design pressures with importance level, design life, roof pitch, average/roof height, blocked-underneath internal pressure and area-reduction Ka.

All wind loads modules

Open Free Roof / Canopy with a free account

7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.