TensorNodeStart free trial
Home / Products / Wind loads / Hoarding

Hoarding calculator for AS/NZS 1170.2, ASCE 7, NBC 2020 and Eurocode 1

Solid hoarding / freestanding wall.

Create a free account to use it

7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.

What it checks

Drag force and base overturning moment per panel.

Clauses and parts as listed in the module: AS/NZ: AS/NZS 1170.2:2021 §5.4.2; US: ASCE/SEI 7-22 29.3.1; CA: NBC 2020 4.1.7.

Inputs

Hoarding takes 4 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.

InputUnitDefault
Wind
Design speed Vdesm/s45
Geometry
Hoarding heightm3
Panel widthm6
Ground clearancem0

Results and report

The module reports: Free-stream q; Aspect b/c; Net Cp,n; Drag force F; Overturning Mot.

Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.

Example with the default inputs

Hoarding with its default inputs for the Australia and New Zealand code system. The main inputs:

InputValue
Design speed Vdes45 m/s
Hoarding height3 m
Panel width6 m
Ground clearance0 m

Headline results:

ResultValue
Free-stream q1.22 kPa
Aspect b/c2.00
Net Cp,n1.40
Drag force F30.6 kN
Overturning Mot45.9 kNm

Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.

Design codes

Hoarding works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.

RegionStandard and edition
Australia and New ZealandAS/NZS 1170.2:2021
United StatesASCE/SEI 7-22
CanadaNBC 2020
EuropeEN 1991-1-4:2005+A1:2010

Use it in full during the 7-day trial of the Professional plan. Paid plans give access to the module packs. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.

Related modules

  • Flag
    Wind drag on a flag/banner and pole base moment
  • Free Roof / Canopy
    Net wind pressure and uplift on a free/canopy roof
  • Monoslope Roof
    Wind pressures on a monoslope (skillion) roof to AS 1170.2 §5.4
  • Purlin & Girt Loads
    Purlin/girt member under wind to AS 4100
  • Terrain Change
    Wind terrain/height multiplier with a terrain-category change to AS 1170.2 §4.2
  • Wind Actions
    Site wind speed and design pressures with importance level, design life, roof pitch, average/roof height, blocked-underneath internal pressure and area-reduction Ka.

All wind loads modules

Open Hoarding with a free account

7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.