Dead & Live Loads calculator for AS/NZS 1170.1, ASCE 7, NBC 2020 and Eurocode 0
Load takedown.
Create a free account to use it
7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.
What it checks
Builds the permanent (G) action from its components and the imposed (Q) action, applies the AS/NZS 1170.0 ULS and SLS combinations, and converts to a design line load over a tributary width.
Inputs
Dead & Live Loads takes 8 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.
| Input | Unit | Default |
|---|---|---|
| Geometry | ||
| Tributary width | m | 3.6 |
| Permanent G | ||
| Slab / structure | kPa | 3.6 |
| Finishes | kPa | 0.5 |
| Services | kPa | 0.1 |
| Partitions | kPa | 0.5 |
| Imposed | ||
| Imposed Q | kPa | 3 |
| Factors | ||
| ψl (long-term) | - | 0.4 |
| ψs (short-term) | - | 0.7 |
Results and report
The module reports: Permanent G; Imposed Q; Governing ULS; SLS line load; G / Q line loads.
It checks: Permanent G; Imposed Q; Governing ULS; SLS (G + ψsQ).
Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.
Example with the default inputs
Dead & Live Loads with its default inputs for the Australia and New Zealand code system. The main inputs:
| Input | Value |
|---|---|
| Tributary width | 3.6 m |
| Slab / structure | 3.6 kPa |
| Finishes | 0.5 kPa |
| Services | 0.1 kPa |
| Partitions | 0.5 kPa |
| Imposed Q | 3 kPa |
| ψl (long-term) | 0.4 |
| ψs (short-term) | 0.7 |
Headline results:
| Result | Value |
|---|---|
| Permanent G | 4.70 kPa |
| Imposed Q | 3.00 kPa |
| Governing ULS | 36.50 (1.2G + 1.5Q) kN/m |
| SLS line load | 24.48 kN/m |
| G / Q line loads | 16.92 / 10.80 kN/m |
Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.
Design codes
Dead & Live Loads works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.
| Region | Standard and edition |
|---|---|
| Australia and New Zealand | AS/NZS 1170.1:2002 |
| United States | ASCE/SEI 7-22 |
| Canada | NBC 2020 |
| Europe | EN 1990:2002+A1:2005 |
This module is one of the 21 basic calculators of the Free plan (one code system, reports carry an Evaluation mark), and it opens fully during the 7-day trial. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.
Related modules
- Earthquake Design Category
Earthquake Design Category (EDC) determination to AS 1170.4 §2 - Flag
Wind drag on a flag/banner and pole base moment - Free Roof / Canopy
Net wind pressure and uplift on a free/canopy roof - Hoarding
Solid hoarding / freestanding wall - Monoslope Roof
Wind pressures on a monoslope (skillion) roof to AS 1170.2 §5.4 - Purlin & Girt Loads
Purlin/girt member under wind to AS 4100 - Snow Loads
Roof snow load s = s_g·C_e·μ_i to AS/NZS 1170.3:2003 for mono-pitched and duo-pitched roofs, obstructed roofs and lower roofs beside a step, with the ground snow load s_g from the snow region and the elevation (Section 5), the alpine or sub-alpine shape coeffi - Static Analysis
Equivalent static earthquake analysis to AS 1170.4
Open Dead & Live Loads with a free account
7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.