TensorNodeStart free trial
Home / Products / Structural loads / Static Analysis

Static Analysis calculator for AS 1170.4, ASCE 7, NBC 2020 and Eurocode 8

Equivalent static earthquake analysis to AS 1170.4.

Create a free account to use it

7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.

What it checks

The spectral shape factor, the horizontal design coefficient, the base shear and its vertical distribution up the height of a regular building.

Inputs

Static Analysis takes 12 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.

InputUnitDefault
Hazard
Hazard factor Z-0.08
Probability factor kp (Table 3.1, annual probability P) Options: 1/2500: 1.8; 1/2000: 1.7; 1/1500: 1.5; 1/1000: 1.3; 1/800: 1.25; 1/500: 1.0; 1/250: 0.75; 1/200: 0.7; +4 more.-1/500: 1.0
Site
Site sub-soil class Options: Ae: strong rock; Be: rock; Ce: shallow soil; De: deep/soft soil; Ee: very soft soil.-Ce: shallow soil
Structure
Structural system (Table 6.5(A): μ, Sp) Options: Enter Sp and μ; Steel special MRF (4, 0.67); Steel intermediate MRF (3, 0.67); Steel ordinary MRF (2, 0.77); Steel mod. ductile CBF (3, 0.67); Steel limited ductile CBF (2, 0.77); Steel fully ductile EBF (4, 0.67); Other steel (2, 0.77); +14 more.-Enter Sp and μ
Structural performance Sp-0.77
Ductility μ-2
Seismic weight WtkN5000
Total height hnm12
Period coeff. kt (Eq 6.2(7)) Options: Steel moment frame: 0.11; Concrete moment frame: 0.075; Steel EBF: 0.06; All other structures: 0.05.-All other structures: 0.05
Number of levels-4
Roof-level weight ÷ typical level weight-1
Period T1 (0 = auto)s0

Results and report

The module reports: Design coefficient Cd; ▶ BASE SHEAR V; Storeys / storey height; Top-level force Fn; Overturning moment (base); Storey shear at base (= V).

It checks: Base shear V; Overturning moment at base; Top-level force Fn; Inter-storey drift limit (needs the frame stiffness).

Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.

Example with the default inputs

Static Analysis with its default inputs for the Australia and New Zealand code system. The main inputs:

InputValue
Hazard factor Z0.08
Probability factor kp (Table 3.1, annual probability P)1/500: 1.0
Site sub-soil classCe: shallow soil
Structural system (Table 6.5(A): μ, Sp)Enter Sp and μ
Structural performance Sp0.77
Ductility μ2
Seismic weight Wt5000 kN
Total height hn12 m

Headline results:

ResultValue
Fundamental period T10.40 s
Spectral shape Ch(T1)3.10
Design coefficient Cd0.0955
▶ BASE SHEAR V477.7 kN (9.6% of Wt)
Storeys / storey height4 levels @ 3.00 m each
Top-level force Fn191.1 kN

Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.

Design codes

Static Analysis works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.

RegionStandard and edition
Australia and New ZealandAS 1170.4:2007
United StatesASCE/SEI 7-22
CanadaNBC 2020
EuropeEN 1998-1:2004+A1:2013

Use it in full during the 7-day trial of the Professional plan. Paid plans give access to the module packs. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.

Related modules

  • Earthquake Design Category
    Earthquake Design Category (EDC) determination to AS 1170.4 §2
  • Dead & Live Loads
    Load takedown
  • Flag
    Wind drag on a flag/banner and pole base moment
  • Free Roof / Canopy
    Net wind pressure and uplift on a free/canopy roof
  • Hoarding
    Solid hoarding / freestanding wall
  • Monoslope Roof
    Wind pressures on a monoslope (skillion) roof to AS 1170.2 §5.4
  • Purlin & Girt Loads
    Purlin/girt member under wind to AS 4100
  • Snow Loads
    Roof snow load s = s_g·C_e·μ_i to AS/NZS 1170.3:2003 for mono-pitched and duo-pitched roofs, obstructed roofs and lower roofs beside a step, with the ground snow load s_g from the snow region and the elevation (Section 5), the alpine or sub-alpine shape coeffi

All structural loads modules

Open Static Analysis with a free account

7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.