TensorNodeStart free trial

Bored Pier design check for AS 2159, IBC 2018, NBC 2020 and Eurocode 7

Bored (CFA/cast-in-situ) pier.

Create a free account to use it

7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.

What it checks

Drilled hole, concrete cast in-situ.

Inputs

Bored Pier takes 10 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.

InputUnitDefault
Pier
Pier diametermm600
Embedded length Lm6
Soil
Shaft adhesion/friction fskPa40
End bearing fbkPa1200
Geotech φg-0.65
Material
Concrete f'cMPa32
fsyMPa500
Reinforcement
Longit. bars: number-10
Bar diameter Options: N16; N20; N24; N28; N32.-N20
Actions
Axial load N*kN450

Results and report

The module reports: Shaft resistance Rs; Base resistance Rb; Design geotech φg·Rug; Structural φNuo; Governing capacity.

It checks: Geotechnical capacity; Structural capacity; Design capacity.

Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.

Example with the default inputs

Bored Pier with its default inputs for the Australia and New Zealand code system. The main inputs:

InputValue
Pier diameter600 mm
Embedded length L6 m
Shaft adhesion/friction fs40 kPa
End bearing fb1200 kPa
Geotech φg0.65
Concrete f'c32 MPa
fsy500 MPa
Longit. bars: number10

Headline results:

ResultValue
Shaft resistance Rs452 kN
Base resistance Rb339 kN
Design geotech φg·Rug515 kN
Structural φNuo5506 kN
Governing capacity515 (geotech) kN

Governing check: Minimum longitudinal reinforcement (0.01·Ag) (AS 3600 §10.7.1(a)), Ast 3142 mm² (10×N20) against ≥ 2827 mm², utilisation 0.90, passes.

Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.

Design codes

Bored Pier works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.

RegionStandard and edition
Australia and New ZealandAS 2159:2009
United StatesIBC 2018, ACI CODE-318-25
CanadaNBC 2020, CSA A23.3-19
EuropeEN 1997-1:2004+A1:2013, EN 1992-1-1:2004+A1:2014, EN 1990:2002+A1:2005

Use it in full during the 7-day trial of the Professional plan. Paid plans give access to the module packs. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.

Related modules

  • Combined Footing
    Combined footing supporting two columns
  • Eccentric Pad
    Eccentrically-loaded pad footing
  • Pad Foundation
    Factored loading with eccentricity, uplift, sliding and overturning; two-way reinforcement by mesh (SL/RL) or bar diameter + spacing.
  • Piered Beam
    Reinforced-concrete ground beam spanning between bored piers
  • Post Footing
    Embedded post footing driven by lateral load, applied moment, load height, footing width/depth and soil φ/γ (embedment depth governs).
  • Strip Footing
    Continuous strip footing under a wall line-load
  • Tree Effects: Piers
    Bored pier through a tree-affected reactive (drying/swelling) zone
  • Basement Wall
    Basement wall

All foundation design modules

Open Bored Pier with a free account