Bored Pier design check for AS 2159, IBC 2018, NBC 2020 and Eurocode 7
Bored (CFA/cast-in-situ) pier.
Create a free account to use it
7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.
What it checks
Drilled hole, concrete cast in-situ.
Inputs
Bored Pier takes 10 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.
| Input | Unit | Default |
|---|---|---|
| Pier | ||
| Pier diameter | mm | 600 |
| Embedded length L | m | 6 |
| Soil | ||
| Shaft adhesion/friction fs | kPa | 40 |
| End bearing fb | kPa | 1200 |
| Geotech φg | - | 0.65 |
| Material | ||
| Concrete f'c | MPa | 32 |
| fsy | MPa | 500 |
| Reinforcement | ||
| Longit. bars: number | - | 10 |
| Bar diameter Options: N16; N20; N24; N28; N32. | - | N20 |
| Actions | ||
| Axial load N* | kN | 450 |
Results and report
The module reports: Shaft resistance Rs; Base resistance Rb; Design geotech φg·Rug; Structural φNuo; Governing capacity.
It checks: Geotechnical capacity; Structural capacity; Design capacity.
Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.
Example with the default inputs
Bored Pier with its default inputs for the Australia and New Zealand code system. The main inputs:
| Input | Value |
|---|---|
| Pier diameter | 600 mm |
| Embedded length L | 6 m |
| Shaft adhesion/friction fs | 40 kPa |
| End bearing fb | 1200 kPa |
| Geotech φg | 0.65 |
| Concrete f'c | 32 MPa |
| fsy | 500 MPa |
| Longit. bars: number | 10 |
Headline results:
| Result | Value |
|---|---|
| Shaft resistance Rs | 452 kN |
| Base resistance Rb | 339 kN |
| Design geotech φg·Rug | 515 kN |
| Structural φNuo | 5506 kN |
| Governing capacity | 515 (geotech) kN |
Governing check: Minimum longitudinal reinforcement (0.01·Ag) (AS 3600 §10.7.1(a)), Ast 3142 mm² (10×N20) against ≥ 2827 mm², utilisation 0.90, passes.
Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.
Design codes
Bored Pier works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.
| Region | Standard and edition |
|---|---|
| Australia and New Zealand | AS 2159:2009 |
| United States | IBC 2018, ACI CODE-318-25 |
| Canada | NBC 2020, CSA A23.3-19 |
| Europe | EN 1997-1:2004+A1:2013, EN 1992-1-1:2004+A1:2014, EN 1990:2002+A1:2005 |
Use it in full during the 7-day trial of the Professional plan. Paid plans give access to the module packs. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.
Related modules
- Combined Footing
Combined footing supporting two columns - Eccentric Pad
Eccentrically-loaded pad footing - Pad Foundation
Factored loading with eccentricity, uplift, sliding and overturning; two-way reinforcement by mesh (SL/RL) or bar diameter + spacing. - Piered Beam
Reinforced-concrete ground beam spanning between bored piers - Post Footing
Embedded post footing driven by lateral load, applied moment, load height, footing width/depth and soil φ/γ (embedment depth governs). - Strip Footing
Continuous strip footing under a wall line-load - Tree Effects: Piers
Bored pier through a tree-affected reactive (drying/swelling) zone - Basement Wall
Basement wall
Open Bored Pier with a free account
7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.