What it checks

Embedded post footing driven by lateral load, applied moment, load height, footing width/depth and soil φ/γ (embedment depth governs).

Inputs

Post Footing takes 14 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.

InputUnitDefault
Loads
Lateral load PkN15
Applied moment MkNm0
Load height hm1.5
Footing
Post/pier diameter or width bm0.45
Embedment depth (provided)m3
Soil
Soil friction angle φ°30
Soil unit weight γkN/m³18
RC Section
Concrete f'c (0 = no RC check)MPa32
fsyMPa500
Post section width b (mm, 0=same as footing dia)mm0
Post section depth D (mm, 0=same as width)mm0
Covermm40
Longit. bars: number (0 = skip RC)-8
Bar diameter Options: N16; N20; N24; N28.-N16

Results and report

The module reports: Passive coeff Kp; Effective height; Required depth d; Provided depth; Design moment at ground; Neutral axis k_u / class; Tension steel; φMu vs M*.

It checks: Embedment depth (non-constrained pole); Design moment at ground line; Flexural capacity; Section ductility k_u (Under-reinforced (ductile)); Tension steel yielding; Minimum reinforcement; Maximum reinforcement (singly).

Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.

Example with the default inputs

Post Footing with its default inputs for the Australia and New Zealand code system. The main inputs:

InputValue
Lateral load P15 kN
Applied moment M0 kNm
Load height h1.5 m
Post/pier diameter or width b0.45 m
Embedment depth (provided)3 m
Soil friction angle φ30 °
Soil unit weight γ18 kN/m³
Concrete f'c (0 = no RC check)32 MPa

Headline results:

ResultValue
Passive coeff Kp3.00
Lateral soil S154.0 kPa
Effective height1.50 m
Required depth d2.42 m
Provided depth3.00 m
Design moment at ground22.5 kNm

Governing check: Minimum longitudinal reinforcement (0.01·Ag) (AS 3600 §10.7.1(a)), Ast 1608 mm² (8×N16) against ≥ 1590 mm², utilisation 0.99, passes.

Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.

Design codes

Post Footing works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.

RegionStandard and edition
Australia and New ZealandNon-constrained pole
United StatesIBC 2018
CanadaNBC 2020
EuropeEN 1997-1:2004+A1:2013

Use it in full during the 7-day trial of the Professional plan. Paid plans give access to the module packs. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.

Related modules

All foundation design modules

Open Post Footing with a free account

7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.