Post Footing design check for IBC 2018, NBC 2020 and Eurocode 7
Post Footing is a module of the footings group, for Australia and New Zealand, United States, Canada and Europe.
Create a free account to use it
7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.
What it checks
Embedded post footing driven by lateral load, applied moment, load height, footing width/depth and soil φ/γ (embedment depth governs).
Inputs
Post Footing takes 14 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.
| Input | Unit | Default |
|---|---|---|
| Loads | ||
| Lateral load P | kN | 15 |
| Applied moment M | kNm | 0 |
| Load height h | m | 1.5 |
| Footing | ||
| Post/pier diameter or width b | m | 0.45 |
| Embedment depth (provided) | m | 3 |
| Soil | ||
| Soil friction angle φ | ° | 30 |
| Soil unit weight γ | kN/m³ | 18 |
| RC Section | ||
| Concrete f'c (0 = no RC check) | MPa | 32 |
| fsy | MPa | 500 |
| Post section width b (mm, 0=same as footing dia) | mm | 0 |
| Post section depth D (mm, 0=same as width) | mm | 0 |
| Cover | mm | 40 |
| Longit. bars: number (0 = skip RC) | - | 8 |
| Bar diameter Options: N16; N20; N24; N28. | - | N16 |
Results and report
The module reports: Passive coeff Kp; Effective height; Required depth d; Provided depth; Design moment at ground; Neutral axis k_u / class; Tension steel; φMu vs M*.
It checks: Embedment depth (non-constrained pole); Design moment at ground line; Flexural capacity; Section ductility k_u (Under-reinforced (ductile)); Tension steel yielding; Minimum reinforcement; Maximum reinforcement (singly).
Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.
Example with the default inputs
Post Footing with its default inputs for the Australia and New Zealand code system. The main inputs:
| Input | Value |
|---|---|
| Lateral load P | 15 kN |
| Applied moment M | 0 kNm |
| Load height h | 1.5 m |
| Post/pier diameter or width b | 0.45 m |
| Embedment depth (provided) | 3 m |
| Soil friction angle φ | 30 ° |
| Soil unit weight γ | 18 kN/m³ |
| Concrete f'c (0 = no RC check) | 32 MPa |
Headline results:
| Result | Value |
|---|---|
| Passive coeff Kp | 3.00 |
| Lateral soil S1 | 54.0 kPa |
| Effective height | 1.50 m |
| Required depth d | 2.42 m |
| Provided depth | 3.00 m |
| Design moment at ground | 22.5 kNm |
Governing check: Minimum longitudinal reinforcement (0.01·Ag) (AS 3600 §10.7.1(a)), Ast 1608 mm² (8×N16) against ≥ 1590 mm², utilisation 0.99, passes.
Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.
Design codes
Post Footing works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.
| Region | Standard and edition |
|---|---|
| Australia and New Zealand | Non-constrained pole |
| United States | IBC 2018 |
| Canada | NBC 2020 |
| Europe | EN 1997-1:2004+A1:2013 |
Use it in full during the 7-day trial of the Professional plan. Paid plans give access to the module packs. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.
Related modules
- Bored Pier
Bored (CFA/cast-in-situ) pier - Combined Footing
Combined footing supporting two columns - Eccentric Pad
Eccentrically-loaded pad footing - Pad Foundation
Factored loading with eccentricity, uplift, sliding and overturning; two-way reinforcement by mesh (SL/RL) or bar diameter + spacing. - Piered Beam
Reinforced-concrete ground beam spanning between bored piers - Strip Footing
Continuous strip footing under a wall line-load - Tree Effects: Piers
Bored pier through a tree-affected reactive (drying/swelling) zone - Basement Wall
Basement wall
Open Post Footing with a free account
7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.