TensorNodeStart free trial
Home / Products / Foundation design / Eccentric Pad

Eccentric Pad design check for AS 3600, ACI 318, CSA A23.3 and Eurocode 7

Eccentrically-loaded pad footing.

Create a free account to use it

7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.

What it checks

Biaxial bearing under N with moments Mx, My: the four corner pressures, the kern (no-uplift) check, and the flexural reinforcement.

Inputs

Eccentric Pad takes 13 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.

InputUnitDefault
Actions
Axial load N*kN800
Moment M*xkNm120
Moment M*ykNm60
Footing
Footing width Bmm2500
Footing length Lmm2500
Footing depth Dmm600
Column sizemm400
Soil
Allowable bearingkPa250
Material
Concrete f'cMPa32
fsyMPa500
Reinforcement
Covermm60
Bar diametermm16
Bar spacingmm200

Results and report

The module reports: Eccentricity ex / ey; Within kern?; q_max / q_min; Face moment / Ast provided; Neutral axis k_u; Steel.

It checks: Bearing (corner q_max); Load within kern; Flexural capacity (stress-block); Minimum reinforcement; Section ductility k_u (Under-reinforced (ductile)); Tension steel yielding; Maximum reinforcement; Tension steel yielding: under-reinforced, ductile; Minimum reinforcement Ast,min.

Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.

Example with the default inputs

Eccentric Pad with its default inputs for the Australia and New Zealand code system. The main inputs:

InputValue
Axial load N*800 kN
Moment M*x120 kNm
Moment M*y60 kNm
Footing width B2500 mm
Footing length L2500 mm
Footing depth D600 mm
Column size400 mm
Allowable bearing250 kPa

Headline results:

ResultValue
Eccentricity ex / ey135 / 67 mm
Within kern?Yes (full bearing)
q_max / q_min212 / 73 kPa
Face moment / Ast provided116.6 kNm/m · 1005 mm²/m
Neutral axis k_u0.041 / Under-reinforced (ductile)
Steelyielding ✓

Governing check: Minimum reinforcement (AS 3600 §8.1.6), Ast,min 919 mm²/m against Ast 1005 mm²/m, utilisation 0.91, passes.

Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.

Design codes

Eccentric Pad works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.

RegionStandard and edition
Australia and New ZealandAS 3600:2018, AS 2159:2009
United StatesACI CODE-318-25
CanadaCSA A23.3-19
EuropeEN 1997-1:2004+A1:2013, EN 1992-1-1:2004+A1:2014, EN 1990:2002+A1:2005

Use it in full during the 7-day trial of the Professional plan. Paid plans give access to the module packs. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.

Related modules

  • Bored Pier
    Bored (CFA/cast-in-situ) pier
  • Combined Footing
    Combined footing supporting two columns
  • Pad Foundation
    Factored loading with eccentricity, uplift, sliding and overturning; two-way reinforcement by mesh (SL/RL) or bar diameter + spacing.
  • Piered Beam
    Reinforced-concrete ground beam spanning between bored piers
  • Post Footing
    Embedded post footing driven by lateral load, applied moment, load height, footing width/depth and soil φ/γ (embedment depth governs).
  • Strip Footing
    Continuous strip footing under a wall line-load
  • Tree Effects: Piers
    Bored pier through a tree-affected reactive (drying/swelling) zone
  • Basement Wall
    Basement wall

All foundation design modules