What it checks
Biaxial bearing under N with moments Mx, My: the four corner pressures, the kern (no-uplift) check, and the flexural reinforcement.
Inputs
Eccentric Pad takes 13 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.
| Input | Unit | Default |
|---|---|---|
| Actions | ||
| Axial load N* | kN | 800 |
| Moment M*x | kNm | 120 |
| Moment M*y | kNm | 60 |
| Footing | ||
| Footing width B | mm | 2500 |
| Footing length L | mm | 2500 |
| Footing depth D | mm | 600 |
| Column size | mm | 400 |
| Soil | ||
| Allowable bearing | kPa | 250 |
| Material | ||
| Concrete f'c | MPa | 32 |
| fsy | MPa | 500 |
| Reinforcement | ||
| Cover | mm | 60 |
| Bar diameter | mm | 16 |
| Bar spacing | mm | 200 |
Results and report
The module reports: Eccentricity ex / ey; Within kern?; q_max / q_min; Face moment / Ast provided; Neutral axis k_u; Steel.
It checks: Bearing (corner q_max); Load within kern; Flexural capacity (stress-block); Minimum reinforcement; Section ductility k_u (Under-reinforced (ductile)); Tension steel yielding; Maximum reinforcement; Tension steel yielding: under-reinforced, ductile; Minimum reinforcement Ast,min.
Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.
Example with the default inputs
Eccentric Pad with its default inputs for the Australia and New Zealand code system. The main inputs:
| Input | Value |
|---|---|
| Axial load N* | 800 kN |
| Moment M*x | 120 kNm |
| Moment M*y | 60 kNm |
| Footing width B | 2500 mm |
| Footing length L | 2500 mm |
| Footing depth D | 600 mm |
| Column size | 400 mm |
| Allowable bearing | 250 kPa |
Headline results:
| Result | Value |
|---|---|
| Eccentricity ex / ey | 135 / 67 mm |
| Within kern? | Yes (full bearing) |
| q_max / q_min | 212 / 73 kPa |
| Face moment / Ast provided | 116.6 kNm/m · 1005 mm²/m |
| Neutral axis k_u | 0.041 / Under-reinforced (ductile) |
| Steel | yielding ✓ |
Governing check: Minimum reinforcement (AS 3600 §8.1.6), Ast,min 919 mm²/m against Ast 1005 mm²/m, utilisation 0.91, passes.
Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.
Design codes
Eccentric Pad works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.
| Region | Standard and edition |
|---|---|
| Australia and New Zealand | AS 3600:2018, AS 2159:2009 |
| United States | ACI CODE-318-25 |
| Canada | CSA A23.3-19 |
| Europe | EN 1997-1:2004+A1:2013, EN 1992-1-1:2004+A1:2014, EN 1990:2002+A1:2005 |
Use it in full during the 7-day trial of the Professional plan. Paid plans give access to the module packs. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.
Related modules
- Bored Pier
Bored (CFA/cast-in-situ) pier - Combined Footing
Combined footing supporting two columns - Pad Foundation
Factored loading with eccentricity, uplift, sliding and overturning; two-way reinforcement by mesh (SL/RL) or bar diameter + spacing. - Piered Beam
Reinforced-concrete ground beam spanning between bored piers - Post Footing
Embedded post footing driven by lateral load, applied moment, load height, footing width/depth and soil φ/γ (embedment depth governs). - Strip Footing
Continuous strip footing under a wall line-load - Tree Effects: Piers
Bored pier through a tree-affected reactive (drying/swelling) zone - Basement Wall
Basement wall
Open Eccentric Pad with a free account
7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.