Tree Effects: Piers design check for AS 2870

Bored pier through a tree-affected reactive (drying/swelling) zone.

Create a free account to use it

7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.

What it checks

Checks the uplift on the shaft from the reactive soil against the structure dead load plus the anchorage below the active zone, and the minimum embedment below that zone.

Inputs

Tree Effects: Piers takes 7 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.

InputUnitDefault
Pier
Pier diametermm450
Pier length Lm6
Soil
Active (reactive) zone depthm2.5
Uplift skin pressure p_swellkPa40
Shaft friction (stable zone)kPa50
Geotech φg-0.65
Loads
Structure dead load NkN50

Results and report

The module reports: Shaft perimeter; Uplift U (active zone); Anchorage R below zone; Resisting N + R; Min embedment below zone.

It checks: Uplift from reactive (tree-dried) zone; Embedment below active zone; Anchorage below active zone.

Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.

Example with the default inputs

Tree Effects: Piers with its default inputs for the Australia and New Zealand code system. The main inputs:

InputValue
Pier diameter450 mm
Pier length L6 m
Active (reactive) zone depth2.5 m
Uplift skin pressure p_swell40 kPa
Shaft friction (stable zone)50 kPa
Geotech φg0.65
Structure dead load N50 kN

Headline results:

ResultValue
Shaft perimeter1.41 m
Uplift U (active zone)141.4 kN
Anchorage R below zone160.8 kN
Resisting N + R210.8 kN
Min embedment below zone3.8 (L 6.0) m

Governing check: Uplift from reactive (tree-dried) zone (AS 2870 §3 / AS 2159), U 141.4 kN against N+R 210.8 kN, utilisation 0.67, passes.

Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.

Design codes

Tree Effects: Piers works to 1 code system in Australia and New Zealand. The standards and editions are listed below; clause numbers are cited in the report.

RegionStandard and edition
Australia and New ZealandAS 2870:2011, AS 2159:2009

Use it in full during the 7-day trial of the Professional plan. Paid plans give access to the module packs. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.

Related modules

  • Bored Pier
    Bored (CFA/cast-in-situ) pier
  • Combined Footing
    Combined footing supporting two columns
  • Eccentric Pad
    Eccentrically-loaded pad footing
  • Pad Foundation
    Factored loading with eccentricity, uplift, sliding and overturning; two-way reinforcement by mesh (SL/RL) or bar diameter + spacing.
  • Piered Beam
    Reinforced-concrete ground beam spanning between bored piers
  • Post Footing
    Embedded post footing driven by lateral load, applied moment, load height, footing width/depth and soil φ/γ (embedment depth governs).
  • Strip Footing
    Continuous strip footing under a wall line-load
  • Basement Wall
    Basement wall

All foundation design modules

Open Tree Effects: Piers with a free account

7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.