Tree Effects: Piers design check for AS 2870
Bored pier through a tree-affected reactive (drying/swelling) zone.
Create a free account to use it
7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.
What it checks
Checks the uplift on the shaft from the reactive soil against the structure dead load plus the anchorage below the active zone, and the minimum embedment below that zone.
Inputs
Tree Effects: Piers takes 7 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.
| Input | Unit | Default |
|---|---|---|
| Pier | ||
| Pier diameter | mm | 450 |
| Pier length L | m | 6 |
| Soil | ||
| Active (reactive) zone depth | m | 2.5 |
| Uplift skin pressure p_swell | kPa | 40 |
| Shaft friction (stable zone) | kPa | 50 |
| Geotech φg | - | 0.65 |
| Loads | ||
| Structure dead load N | kN | 50 |
Results and report
The module reports: Shaft perimeter; Uplift U (active zone); Anchorage R below zone; Resisting N + R; Min embedment below zone.
It checks: Uplift from reactive (tree-dried) zone; Embedment below active zone; Anchorage below active zone.
Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.
Example with the default inputs
Tree Effects: Piers with its default inputs for the Australia and New Zealand code system. The main inputs:
| Input | Value |
|---|---|
| Pier diameter | 450 mm |
| Pier length L | 6 m |
| Active (reactive) zone depth | 2.5 m |
| Uplift skin pressure p_swell | 40 kPa |
| Shaft friction (stable zone) | 50 kPa |
| Geotech φg | 0.65 |
| Structure dead load N | 50 kN |
Headline results:
| Result | Value |
|---|---|
| Shaft perimeter | 1.41 m |
| Uplift U (active zone) | 141.4 kN |
| Anchorage R below zone | 160.8 kN |
| Resisting N + R | 210.8 kN |
| Min embedment below zone | 3.8 (L 6.0) m |
Governing check: Uplift from reactive (tree-dried) zone (AS 2870 §3 / AS 2159), U 141.4 kN against N+R 210.8 kN, utilisation 0.67, passes.
Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.
Design codes
Tree Effects: Piers works to 1 code system in Australia and New Zealand. The standards and editions are listed below; clause numbers are cited in the report.
| Region | Standard and edition |
|---|---|
| Australia and New Zealand | AS 2870:2011, AS 2159:2009 |
Use it in full during the 7-day trial of the Professional plan. Paid plans give access to the module packs. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.
Related modules
- Bored Pier
Bored (CFA/cast-in-situ) pier - Combined Footing
Combined footing supporting two columns - Eccentric Pad
Eccentrically-loaded pad footing - Pad Foundation
Factored loading with eccentricity, uplift, sliding and overturning; two-way reinforcement by mesh (SL/RL) or bar diameter + spacing. - Piered Beam
Reinforced-concrete ground beam spanning between bored piers - Post Footing
Embedded post footing driven by lateral load, applied moment, load height, footing width/depth and soil φ/γ (embedment depth governs). - Strip Footing
Continuous strip footing under a wall line-load - Basement Wall
Basement wall
Open Tree Effects: Piers with a free account
7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.