Bearing pressure, the cantilever face moment and reinforcement, and one-way shear, all per metre run.

Inputs

Strip Footing takes 14 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.

InputUnitDefault
Actions
Wall line load P*kN/m120
Footing
Footing width Bm1.2
Footing depth Dmm400
Wall thicknessmm200
Soil
Allowable bearingkPa200
Material
Concrete f'cMPa25
fsyMPa500
Reinforcement
Covermm60
Bar diamm16
Bar spacingmm200
Longitudinal bars (bottom, B2): size Options: N10; N12; N16; N20; N24; N28; N32.-N12
Longitudinal bars (bottom, B2): spacing across the widthmm300
Top longitudinal bars (T1): size Options: N10; N12; N16; N20; N24; N28; N32.-N12
Top longitudinal bars (T1): spacing across the widthmm250

Results and report

The module reports: Bearing pressure q; Neutral axis k_u; Steel; Projection; Face moment; Reinforcement; Shear φVuc.

It checks: Bearing pressure; One-way shear; Flexural capacity (stress-block); Minimum reinforcement; Section ductility k_u (Under-reinforced (ductile)); Tension steel yielding; Maximum reinforcement; Tension steel yielding: under-reinforced, ductile; Minimum reinforcement Ast,min.

Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.

Example with the default inputs

Strip Footing with its default inputs for the Australia and New Zealand code system. The main inputs:

InputValue
Wall line load P*120 kN/m
Footing width B1.2 m
Footing depth D400 mm
Wall thickness200 mm
Allowable bearing200 kPa
Concrete f'c25 MPa
fsy500 MPa
Cover60 mm

Headline results:

ResultValue
Bearing pressure q109.6 (allow 200) kPa
Neutral axis k_u0.082 / Under-reinforced (ductile)
Steelyielding ✓
Projection0.50 m
Face moment13.7 kNm/m
Reinforcement578 mm²/m

Governing check: Bottom longitudinal bars B2: at least half the minimum distribution steel of B × h at the bottom face (AS 3600:2018 9.4.3 (1.75 × 10⁻³ bD, secondary direction, free to shrink), split equally between the two faces), required 420 mm² against provided N12 at 300 mm = 452 mm², utilisation 0.93, passes.

Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.

Design codes

Strip Footing works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.

RegionStandard and edition
Australia and New ZealandAS 3600:2018
United StatesACI CODE-318-25
CanadaCSA A23.3-19
EuropeEN 1997-1:2004+A1:2013, EN 1992-1-1:2004+A1:2014, EN 1990:2002+A1:2005

This module is one of the 21 basic calculators of the Free plan (one code system, reports carry an Evaluation mark), and it opens fully during the 7-day trial. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.

Related modules

  • Bored Pier
    Bored (CFA/cast-in-situ) pier
  • Combined Footing
    Combined footing supporting two columns
  • Eccentric Pad
    Eccentrically-loaded pad footing
  • Pad Foundation
    Factored loading with eccentricity, uplift, sliding and overturning; two-way reinforcement by mesh (SL/RL) or bar diameter + spacing.
  • Piered Beam
    Reinforced-concrete ground beam spanning between bored piers
  • Post Footing
    Embedded post footing driven by lateral load, applied moment, load height, footing width/depth and soil φ/γ (embedment depth governs).
  • Tree Effects: Piers
    Bored pier through a tree-affected reactive (drying/swelling) zone
  • Basement Wall
    Basement wall

All foundation design modules

Open Strip Footing with a free account

7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.