Piered Beam design check for AS 3600, ACI 318, CSA A23.3 and Eurocode 7
Reinforced-concrete ground beam spanning between bored piers.
Create a free account to use it
7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.
What it checks
The wall/structure line load gives the span moment and shear; the RC section is checked for flexure, minimum steel, shear and deflection.
Inputs
Piered Beam takes 14 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.
| Input | Unit | Default |
|---|---|---|
| Section | ||
| Beam width b | mm | 400 |
| Beam depth D | mm | 600 |
| Material | ||
| Concrete f'c | MPa | 32 |
| Steel fsy | MPa | 500 |
| Reinforcement | ||
| Cover | mm | 50 |
| Tension reo | ||
| Tension bars: number | - | 4 |
| Tension bar diameter Options: N16; N20; N24; N28; N32. | - | N20 |
| Compression reo | ||
| Compression bars: number (0 = singly) | - | 0 |
| Compression bar diameter Options: N12; N16; N20; N24. | - | N16 |
| Shear ligatures | ||
| Ligature legs | - | 2 |
| Ligature diameter Options: none; R10/N10; N12. | - | R10/N10 |
| Ligature spacing | mm | 200 |
| Loads | ||
| Pier spacing L | m | 4.5 |
| Line load w* | kN/m | 40 |
Results and report
The module reports: Effective depth d; Design moment M*; Moment capacity φMu; Neutral axis k_u; Tension steel; Shear capacity φVu.
It checks: Flexural capacity; Section ductility k_u (Under-reinforced (ductile)); Tension steel yielding; Minimum reinforcement; Maximum reinforcement (singly); Shear capacity (ligatures); Deflection (SLS), total incl. long-term; Crack control (SLS).
Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.
Example with the default inputs
Piered Beam with its default inputs for the Australia and New Zealand code system. The main inputs:
| Input | Value |
|---|---|
| Beam width b | 400 mm |
| Beam depth D | 600 mm |
| Concrete f'c | 32 MPa |
| Steel fsy | 500 MPa |
| Cover | 50 mm |
| Tension bars: number | 4 |
| Tension bar diameter | N20 |
| Compression bars: number (0 = singly) | 0 |
Headline results:
| Result | Value |
|---|---|
| Effective depth d | 530 mm |
| Design moment M* | 101.3 kNm |
| Moment capacity φMu | 266.7 kNm |
| Neutral axis k_u | 0.130 / Under-reinforced (ductile) |
| Tension steel | yielding ✓ |
| Shear capacity φVu | 314.8 / V* 90.0 kN |
Governing check: Flexural capacity (AS 3600 §8.1), M* 101.3 kNm against φMu 266.7 kNm, utilisation 0.38, passes.
Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.
Design codes
Piered Beam works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.
| Region | Standard and edition |
|---|---|
| Australia and New Zealand | AS 3600:2018 |
| United States | ACI CODE-318-25 |
| Canada | CSA A23.3-19 |
| Europe | EN 1997-1:2004+A1:2013, EN 1992-1-1:2004+A1:2014, EN 1990:2002+A1:2005 |
Use it in full during the 7-day trial of the Professional plan. Paid plans give access to the module packs. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.
Related modules
- Bored Pier
Bored (CFA/cast-in-situ) pier - Combined Footing
Combined footing supporting two columns - Eccentric Pad
Eccentrically-loaded pad footing - Pad Foundation
Factored loading with eccentricity, uplift, sliding and overturning; two-way reinforcement by mesh (SL/RL) or bar diameter + spacing. - Post Footing
Embedded post footing driven by lateral load, applied moment, load height, footing width/depth and soil φ/γ (embedment depth governs). - Strip Footing