TensorNodeStart free trial
Home / Products / Foundation design / Piered Beam

Piered Beam design check for AS 3600, ACI 318, CSA A23.3 and Eurocode 7

Reinforced-concrete ground beam spanning between bored piers.

Create a free account to use it

7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.

What it checks

The wall/structure line load gives the span moment and shear; the RC section is checked for flexure, minimum steel, shear and deflection.

Inputs

Piered Beam takes 14 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.

InputUnitDefault
Section
Beam width bmm400
Beam depth Dmm600
Material
Concrete f'cMPa32
Steel fsyMPa500
Reinforcement
Covermm50
Tension reo
Tension bars: number-4
Tension bar diameter Options: N16; N20; N24; N28; N32.-N20
Compression reo
Compression bars: number (0 = singly)-0
Compression bar diameter Options: N12; N16; N20; N24.-N16
Shear ligatures
Ligature legs-2
Ligature diameter Options: none; R10/N10; N12.-R10/N10
Ligature spacingmm200
Loads
Pier spacing Lm4.5
Line load w*kN/m40

Results and report

The module reports: Effective depth d; Design moment M*; Moment capacity φMu; Neutral axis k_u; Tension steel; Shear capacity φVu.

It checks: Flexural capacity; Section ductility k_u (Under-reinforced (ductile)); Tension steel yielding; Minimum reinforcement; Maximum reinforcement (singly); Shear capacity (ligatures); Deflection (SLS), total incl. long-term; Crack control (SLS).

Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.

Example with the default inputs

Piered Beam with its default inputs for the Australia and New Zealand code system. The main inputs:

InputValue
Beam width b400 mm
Beam depth D600 mm
Concrete f'c32 MPa
Steel fsy500 MPa
Cover50 mm
Tension bars: number4
Tension bar diameterN20
Compression bars: number (0 = singly)0

Headline results:

ResultValue
Effective depth d530 mm
Design moment M*101.3 kNm
Moment capacity φMu266.7 kNm
Neutral axis k_u0.130 / Under-reinforced (ductile)
Tension steelyielding ✓
Shear capacity φVu314.8 / V* 90.0 kN

Governing check: Flexural capacity (AS 3600 §8.1), M* 101.3 kNm against φMu 266.7 kNm, utilisation 0.38, passes.

Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.

Design codes

Piered Beam works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.

RegionStandard and edition
Australia and New ZealandAS 3600:2018
United StatesACI CODE-318-25
CanadaCSA A23.3-19
EuropeEN 1997-1:2004+A1:2013, EN 1992-1-1:2004+A1:2014, EN 1990:2002+A1:2005

Use it in full during the 7-day trial of the Professional plan. Paid plans give access to the module packs. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.

Related modules

  • Bored Pier
    Bored (CFA/cast-in-situ) pier
  • Combined Footing
    Combined footing supporting two columns
  • Eccentric Pad
    Eccentrically-loaded pad footing
  • Pad Foundation
    Factored loading with eccentricity, uplift, sliding and overturning; two-way reinforcement by mesh (SL/RL) or bar diameter + spacing.
  • Post Footing
    Embedded post footing driven by lateral load, applied moment, load height, footing width/depth and soil φ/γ (embedment depth governs).
  • Strip Footing
    Continuous strip footing under a wall line-load
  • Tree Effects: Piers
    Bored pier through a tree-affected reactive (drying/swelling) zone
  • Basement Wall
    Basement wall

All foundation design modules

Open Piered Beam with a free account

7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.