Residential Slab design check for AS 2870, IBC 2018, NBC 2020 and Eurocode 2
Stiffened-raft / waffle footing screening to AS 2870.
Create a free account to use it
7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.
What it checks
For the site class and construction type it gives the deemed-to-comply stiffening-beam depth and maximum beam spacing (Table 3.1) and checks the provided raft against them.
Clauses and parts as listed in the module: CA: NBC 2020 Part 9 / CSA A23.1 / A23.3.
Inputs
Residential Slab takes 5 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.
| Input | Unit | Default |
|---|---|---|
| Site | ||
| Site class Options: S: slightly reactive; M: moderate; H1: highly; H2: highly; E: extreme. | - | M: moderate |
| or y_s (0 = use class) | mm | 0 |
| Structure | ||
| Supported construction Options: Clad frame; Masonry veneer; Articulated masonry; Full masonry. | - | Masonry veneer |
| Raft | ||
| Provided beam depth | mm | 450 |
| Provided beam spacing | m | 4 |
Results and report
The module reports: Site class; Required beam depth; Provided beam depth; Maximum beam spacing; Provided spacing.
It checks: Stiffening-beam depth; Beam spacing; Site classification.
Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.
Example with the default inputs
Residential Slab with its default inputs for the Australia and New Zealand code system. The main inputs:
| Input | Value |
|---|---|
| Site class | M: moderate |
| or y_s (0 = use class) | 0 mm |
| Supported construction | Masonry veneer |
| Provided beam depth | 450 mm |
| Provided beam spacing | 4 m |
Headline results:
| Result | Value |
|---|---|
| Site class | M |
| Required beam depth | 400 mm |
| Provided beam depth | 450 mm |
| Maximum beam spacing | 5.0 m |
| Provided spacing | 4.0 m |
Governing check: Stiffening-beam depth (AS 2870 Table 3.1), req 400 mm against prov 450 mm, utilisation 0.89, passes.
Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.
Design codes
Residential Slab works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.
| Region | Standard and edition |
|---|---|
| Australia and New Zealand | AS 2870:2011 |
| United States | IBC 2018, IRC 2018, ACI CODE-318-25 |
| Canada | NBC 2020, CSA A23.1-19, CSA A23.3-19 |
| Europe | EN 1992-1-1:2004+A1:2014, EN 1997-1:2004+A1:2013, EN 1990:2002+A1:2005 |
Use it in full during the 7-day trial of the Professional plan. Paid plans give access to the module packs. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.
Related modules
- Basement Wall
Basement wall - Earth Pressure
Lateral earth pressure by Rankine theory - Industrial Slab
Industrial slab-on-grade under a concentrated (wheel/post) load - Retaining Wall
Generic cantilever retaining wall - Sleeper Wall
Sleeper wall - Tree Effects: y_s
Characteristic surface movement y_s and AS 2870 site classification, including the effect of nearby trees that dry the soil more deeply - Bored Pier
Bored (CFA/cast-in-situ) pier - Combined Footing
Combined footing supporting two columns
Open Residential Slab with a free account
7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.