TensorNodeStart free trial
Home / Products / Foundation design / Retaining Wall

Retaining Wall design check for AS 4678, ACI 318, CSA A23.3 and Eurocode 7

Generic cantilever retaining wall.

Create a free account to use it

7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.

What it checks

Toe and heel, base thickness, optional shear key and drained/undrained (water table) condition; stem BMD/SFD, overturning, sliding (incl.

Inputs

Retaining Wall takes 19 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.

InputUnitDefault
Retained height Hm3
Base width Bm2.6
Toe lengthm0.6
Stem thicknessmm300
Base thicknessmm400
Soil γkN/m³18
Allowable bearing q_allkPa150
Soil φ°30
Base friction μ-0.5
Drained backfill (no water)-Yes
Shear key Options: None; Base shear key.-None
Surcharge qkPa5
Strip loadkPa0
Strip offsetm1
Backfill condition (AS 4678 Table 5.1(A)) Options: Controlled fill, Class I; Controlled fill, Class II; Uncontrolled fill; In situ material.-Controlled fill, Class II
Structure classification (AS 4678 Table 1.1) Options: A: minimal damage, loss of access; B: moderate damage, loss of services; C: significant damage or risk to life.-B: moderate damage, loss of services
Stem bar diamm16
Stem bar spacingmm200
Covermm50

Results and report

The module reports: Stem k_u / class; Stem steel; Active coeff Ka; Passive coeff Kp; Active thrust Pa; Hydrostatic Pw; Total thrust; Base moment; Key passive Pkey; Sliding resistance; Toe / heel length; Eccentricity e.

It checks: Overturning (stability, load case B); Sliding (stability, load case B); Bearing (toe pressure, service loads); Stem Flexural capacity (stress-block); Stem Minimum reinforcement; Stem Section ductility k_u (Under-reinforced (ductile)); Stem Tension steel yielding; Stem Maximum reinforcement; Tension steel yielding: under-reinforced, ductile; Minimum reinforcement Ast,min.

Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.

Example with the default inputs

Retaining Wall with its default inputs for the Australia and New Zealand code system. The main inputs:

InputValue
Retained height H3 m
Base width B2.6 m
Toe length0.6 m
Stem thickness300 mm
Base thickness400 mm
Soil γ18 kN/m³
Allowable bearing q_all150 kPa
Soil φ30 °

Headline results:

ResultValue
Stem k_u / class0.091 / Under-reinforced (ductile)
Stem steelyielding ✓
Active coeff Ka0.369
Passive coeff Kp2.71
Active thrust Pa29.9 kN/m
Hydrostatic Pw0.0 kN/m

Governing check: Sliding (stability, load case B) (AS 4678 App J3(i), Cl 5.2), S* 45.6 kN against R* 49.8 kN (0.8G, φ_nφ_uφ = 0.900 on μ), utilisation 0.92, passes.

Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.

Design codes

Retaining Wall works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.

RegionStandard and edition
Australia and New ZealandAS 4678:2002, AS 3600:2018
United StatesACI CODE-318-25
CanadaCSA A23.3-19
EuropeEN 1997-1:2004+A1:2013, EN 1992-1-1:2004+A1:2014

Use it in full during the 7-day trial of the Professional plan. Paid plans give access to the module packs. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.

Related modules

All foundation design modules

Open Retaining Wall with a free account

7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.