Sleeper Wall design check for AS 4678, IBC 2018, NBC 2020 and Eurocode 7
Sleeper wall.
Create a free account to use it
7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.
What it checks
Steel posts embedded in soil, with timber or concrete sleeper planks spanning horizontally between posts.
Inputs
Sleeper Wall takes 8 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.
| Input | Unit | Default |
|---|---|---|
| Geometry | ||
| Retained height H | m | 1.2 |
| Post spacing | m | 1.8 |
| Embedment depth | m | 1 |
| Post | ||
| Post section Options: 150UC30.0; 200UC46.2; 250UC72.9. | - | 150UC30.0 |
| Post yield fy | MPa | 300 |
| Soil | ||
| Soil unit weight γ | kN/m³ | 18 |
| Friction angle φ | ° | 30 |
| Loads | ||
| Surcharge q | kPa | 2.5 |
Results and report
The module reports: Active coefficient Ka; Thrust per post; Post base moment; Post capacity φMs; Embedment.
It checks: Post bending; Embedment (overturning).
Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.
Example with the default inputs
Sleeper Wall with its default inputs for the Australia and New Zealand code system. The main inputs:
| Input | Value |
|---|---|
| Retained height H | 1.2 m |
| Post spacing | 1.8 m |
| Embedment depth | 1 m |
| Post section | 150UC30.0 |
| Post yield fy | 300 MPa |
| Soil unit weight γ | 18 kN/m³ |
| Friction angle φ | 30 ° |
| Surcharge q | 2.5 kPa |
Headline results:
| Result | Value |
|---|---|
| Active coefficient Ka | 0.333 |
| Thrust per post | 9.6 kN |
| Post base moment | 4.2 kNm |
| Post capacity φMs | 60.2 kNm |
| Embedment | 1.00 m |
Governing check: Embedment (overturning) (Broms / statics), M* 4.2 kNm against 18.0 kNm, utilisation 0.23, passes.
Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.
Design codes
Sleeper Wall works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.
| Region | Standard and edition |
|---|---|
| Australia and New Zealand | AS 4678:2002 |
| United States | IBC 2018, ANSI/AWC NDS-2018, ANSI/AISC 360-22 |
| Canada | NBC 2020, CSA O86-19, CSA S16-19 |
| Europe | EN 1997-1:2004+A1:2013, EN 1993-1-1:2005+A1:2014, EN 1995-1-1:2004+A2:2014 |
Use it in full during the 7-day trial of the Professional plan. Paid plans give access to the module packs. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.
Related modules
- Basement Wall
Basement wall - Earth Pressure
Lateral earth pressure by Rankine theory - Industrial Slab
Industrial slab-on-grade under a concentrated (wheel/post) load - Residential Slab
Stiffened-raft / waffle footing screening to AS 2870 - Retaining Wall
Generic cantilever retaining wall - Tree Effects: y_s
Characteristic surface movement y_s and AS 2870 site classification, including the effect of nearby trees that dry the soil more deeply - Bored Pier
Bored (CFA/cast-in-situ) pier - Combined Footing
Combined footing supporting two columns
Open Sleeper Wall with a free account
7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.