TensorNodeStart free trial
Home / Products / Foundation design / Sleeper Wall

Sleeper Wall design check for AS 4678, IBC 2018, NBC 2020 and Eurocode 7

Sleeper wall.

Create a free account to use it

7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.

What it checks

Steel posts embedded in soil, with timber or concrete sleeper planks spanning horizontally between posts.

Inputs

Sleeper Wall takes 8 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.

InputUnitDefault
Geometry
Retained height Hm1.2
Post spacingm1.8
Embedment depthm1
Post
Post section Options: 150UC30.0; 200UC46.2; 250UC72.9.-150UC30.0
Post yield fyMPa300
Soil
Soil unit weight γkN/m³18
Friction angle φ°30
Loads
Surcharge qkPa2.5

Results and report

The module reports: Active coefficient Ka; Thrust per post; Post base moment; Post capacity φMs; Embedment.

It checks: Post bending; Embedment (overturning).

Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.

Example with the default inputs

Sleeper Wall with its default inputs for the Australia and New Zealand code system. The main inputs:

InputValue
Retained height H1.2 m
Post spacing1.8 m
Embedment depth1 m
Post section150UC30.0
Post yield fy300 MPa
Soil unit weight γ18 kN/m³
Friction angle φ30 °
Surcharge q2.5 kPa

Headline results:

ResultValue
Active coefficient Ka0.333
Thrust per post9.6 kN
Post base moment4.2 kNm
Post capacity φMs60.2 kNm
Embedment1.00 m

Governing check: Embedment (overturning) (Broms / statics), M* 4.2 kNm against 18.0 kNm, utilisation 0.23, passes.

Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.

Design codes

Sleeper Wall works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.

RegionStandard and edition
Australia and New ZealandAS 4678:2002
United StatesIBC 2018, ANSI/AWC NDS-2018, ANSI/AISC 360-22
CanadaNBC 2020, CSA O86-19, CSA S16-19
EuropeEN 1997-1:2004+A1:2013, EN 1993-1-1:2005+A1:2014, EN 1995-1-1:2004+A2:2014

Use it in full during the 7-day trial of the Professional plan. Paid plans give access to the module packs. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.

Related modules

All foundation design modules

Open Sleeper Wall with a free account

7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.