TensorNodeStart free trial

Weld Group design check for AS 4100, AISC 360, CSA S16 and Eurocode 3

Fillet weld group under in-plane eccentric shear to AS 4100 §9.7.

Create a free account to use it

7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.

What it checks

The welds are treated as unit-throat line elements; the direct shear and the torsional shear from the eccentric moment are combined at the critical point and checked against the per-length capac.

Inputs

Weld Group takes 8 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.

InputUnitDefault
Group
Weld configuration Options: Two vertical lines; Box (4 sides).-Two vertical lines
Weld depth dmm200
Weld width / gauge bmm120
Weld
Fillet legmm8
Electrode Options: E43XX (430); E49XX (490); E55XX (550).-E49XX (490)
Weld category Options: SP (φ 0.8); GP (φ 0.6).-SP (φ 0.8)
Actions
In-plane shear V*kN150
Eccentricity emm100

Results and report

The module reports: Configuration; Weld length Lw; Polar I_p (unit throat); Direct / resultant; Capacity φvw.

It checks: Weld group (critical point).

Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.

Example with the default inputs

Weld Group with its default inputs for the Australia and New Zealand code system. The main inputs:

InputValue
Weld configurationTwo vertical lines
Weld depth d200 mm
Weld width / gauge b120 mm
Fillet leg8 mm
ElectrodeE49XX (490)
Weld categorySP (φ 0.8)
In-plane shear V*150 kN
Eccentricity e100 mm

Headline results:

ResultValue
ConfigurationTwo vertical
Weld length Lw400 mm
Polar I_p (unit throat)2.77×10⁶ mm³
Direct / resultant0.375 / 0.884 kN/mm
Capacity φvw1.330 kN/mm

Governing check: Weld group (critical point) (AS 4100 §9.7.3.10), fr 0.884 kN/mm against φvw 1.330 kN/mm, utilisation 0.66, passes.

Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.

Design codes

Weld Group works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.

RegionStandard and edition
Australia and New ZealandAS 4100:2020
United StatesANSI/AISC 360-22
CanadaCSA S16-19
EuropeEN 1993-1-8:2005

Use it in full during the 7-day trial of the Professional plan. Paid plans give access to the module packs. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.

Related modules

  • Bolt Group
    Bolt group under shear plus an out-of-plane moment to AS 4100 §9
  • Bolt Tension
    Bolt in tension with prying to AS 4100 §9
  • Eccentric Bolt Group
    Bolt group under in-plane eccentric shear (a bracket) to AS 4100 §9
  • Anchor Bolt
    Fastening to concrete (cast-in or post-installed anchor group) to AS 5216
  • Base Plate
    Steel column base plate to AS 3600 §12.6 and AS 4100
  • Bolts
    Single high-strength bolt capacity to AS 4100 §9.3
  • Cleat Plate
    Fin/cleat shear connection to AS 4100 §9
  • End Plate
    Bolted moment end-plate connection to AS 4100 §9

All connection design modules

Open Weld Group with a free account