Bolt Group design check for AS 4100, AISC 360, CSA S16 and Eurocode 3
Bolt group under shear plus an out-of-plane moment to AS 4100 §9.
Create a free account to use it
7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.
What it checks
The shear is shared equally while the moment is resisted by tension that grows linearly from the group centroid; the top (extreme) bolt and the combined shear-tension interaction govern.
Inputs
Bolt Group takes 8 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.
| Input | Unit | Default |
|---|---|---|
| Pattern | ||
| Rows (vertical) | - | 4 |
| Columns | - | 2 |
| Row pitch | mm | 70 |
| Bolts | ||
| Bolt size Options: M16; M20; M24; M30. | - | M20 |
| Bolt grade Options: 4.6; 8.8; 10.9. | - | 8.8 |
| Ply thickness | mm | 10 |
| Actions | ||
| Design shear V* | kN | 120 |
| Out-of-plane moment M* | kNm | 40 |
Results and report
The module reports: Bolts (rows × cols); Σd² (group); Shear per bolt; Tension top bolt; Combined (top bolt).
It checks: Shear per bolt; Tension (top bolt); Combined (top bolt).
Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.
Example with the default inputs
Bolt Group with its default inputs for the Australia and New Zealand code system. The main inputs:
| Input | Value |
|---|---|
| Rows (vertical) | 4 |
| Columns | 2 |
| Row pitch | 70 mm |
| Bolt size | M20 |
| Bolt grade | 8.8 |
| Ply thickness | 10 mm |
| Design shear V* | 120 kN |
| Out-of-plane moment M* | 40 kNm |
Headline results:
| Result | Value |
|---|---|
| Bolts (rows × cols) | 4 × 2 = 8 |
| Σd² (group) | 49000 mm² |
| Shear per bolt | 15.0 (φVf 93) kN |
| Tension top bolt | 85.7 (φNtf 163) kN |
| Combined (top bolt) | 0.30 ≤ 1.0 |
Governing check: Tension (top bolt) (AS 4100 §9.3.2.2), Ntb 85.7 kN against φNtf 162.7 kN, utilisation 0.53, passes.
Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.
Design codes
Bolt Group works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.
| Region | Standard and edition |
|---|---|
| Australia and New Zealand | AS 4100:2020 |
| United States | ANSI/AISC 360-22 |
| Canada | CSA S16-19 |
| Europe | EN 1993-1-8:2005 |
Use it in full during the 7-day trial of the Professional plan. Paid plans give access to the module packs. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.
Related modules
- Bolt Tension
Bolt in tension with prying to AS 4100 §9 - Eccentric Bolt Group
Bolt group under in-plane eccentric shear (a bracket) to AS 4100 §9 - Weld Group
Fillet weld group under in-plane eccentric shear to AS 4100 §9.7 - Anchor Bolt
Fastening to concrete (cast-in or post-installed anchor group) to AS 5216 - Base Plate
Steel column base plate to AS 3600 §12.6 and AS 4100 - Bolts
Single high-strength bolt capacity to AS 4100 §9.3 - Cleat Plate
Fin/cleat shear connection to AS 4100 §9 - End Plate
Bolted moment end-plate connection to AS 4100 §9
Open Bolt Group with a free account
7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.