TensorNodeStart free trial

Bolt Group design check for AS 4100, AISC 360, CSA S16 and Eurocode 3

Bolt group under shear plus an out-of-plane moment to AS 4100 §9.

Create a free account to use it

7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.

What it checks

The shear is shared equally while the moment is resisted by tension that grows linearly from the group centroid; the top (extreme) bolt and the combined shear-tension interaction govern.

Inputs

Bolt Group takes 8 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.

InputUnitDefault
Pattern
Rows (vertical)-4
Columns-2
Row pitchmm70
Bolts
Bolt size Options: M16; M20; M24; M30.-M20
Bolt grade Options: 4.6; 8.8; 10.9.-8.8
Ply thicknessmm10
Actions
Design shear V*kN120
Out-of-plane moment M*kNm40

Results and report

The module reports: Bolts (rows × cols); Σd² (group); Shear per bolt; Tension top bolt; Combined (top bolt).

It checks: Shear per bolt; Tension (top bolt); Combined (top bolt).

Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.

Example with the default inputs

Bolt Group with its default inputs for the Australia and New Zealand code system. The main inputs:

InputValue
Rows (vertical)4
Columns2
Row pitch70 mm
Bolt sizeM20
Bolt grade8.8
Ply thickness10 mm
Design shear V*120 kN
Out-of-plane moment M*40 kNm

Headline results:

ResultValue
Bolts (rows × cols)4 × 2 = 8
Σd² (group)49000 mm²
Shear per bolt15.0 (φVf 93) kN
Tension top bolt85.7 (φNtf 163) kN
Combined (top bolt)0.30 ≤ 1.0

Governing check: Tension (top bolt) (AS 4100 §9.3.2.2), Ntb 85.7 kN against φNtf 162.7 kN, utilisation 0.53, passes.

Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.

Design codes

Bolt Group works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.

RegionStandard and edition
Australia and New ZealandAS 4100:2020
United StatesANSI/AISC 360-22
CanadaCSA S16-19
EuropeEN 1993-1-8:2005

Use it in full during the 7-day trial of the Professional plan. Paid plans give access to the module packs. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.

Related modules

  • Bolt Tension
    Bolt in tension with prying to AS 4100 §9
  • Eccentric Bolt Group
    Bolt group under in-plane eccentric shear (a bracket) to AS 4100 §9
  • Weld Group
    Fillet weld group under in-plane eccentric shear to AS 4100 §9.7
  • Anchor Bolt
    Fastening to concrete (cast-in or post-installed anchor group) to AS 5216
  • Base Plate
    Steel column base plate to AS 3600 §12.6 and AS 4100
  • Bolts
    Single high-strength bolt capacity to AS 4100 §9.3
  • Cleat Plate
    Fin/cleat shear connection to AS 4100 §9
  • End Plate
    Bolted moment end-plate connection to AS 4100 §9

All connection design modules

Open Bolt Group with a free account

7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.