Eccentric Bolt Group design check for AS 4100, AISC 360, CSA S16 and Eurocode 3
Bolt group under in-plane eccentric shear (a bracket) to AS 4100 §9.
Create a free account to use it
7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.
What it checks
The elastic vector method combines the direct shear with the torsional shear from the eccentric moment; the critical corner bolt governs.
Inputs
Eccentric Bolt Group takes 10 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.
| Input | Unit | Default |
|---|---|---|
| Pattern | ||
| Rows (vertical) | - | 3 |
| Columns | - | 2 |
| Row pitch | mm | 70 |
| Column gauge | mm | 70 |
| Bolts | ||
| Bolt size Options: M16; M20; M24; M30. | - | M20 |
| Bolt grade Options: 4.6; 8.8; 10.9. | - | 8.8 |
| Ply thickness | mm | 10 |
| Ply tensile fup | MPa | 440 |
| Actions | ||
| In-plane shear V* | kN | 150 |
| Eccentricity e | mm | 100 |
Results and report
The module reports: Bolts (rows × cols); Polar I_p; Direct / torsion; Critical bolt resultant; Bearing φVb.
It checks: Critical bolt (direct + torsion); Bolt bearing on plate.
Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.
Example with the default inputs
Eccentric Bolt Group with its default inputs for the Australia and New Zealand code system. The main inputs:
| Input | Value |
|---|---|
| Rows (vertical) | 3 |
| Columns | 2 |
| Row pitch | 70 mm |
| Column gauge | 70 mm |
| Bolt size | M20 |
| Bolt grade | 8.8 |
| Ply thickness | 10 mm |
| Ply tensile fup | 440 MPa |
Headline results:
| Result | Value |
|---|---|
| Bolts (rows × cols) | 3 × 2 = 6 |
| Polar I_p | 26950 mm² |
| Direct / torsion | 25.0 / √(39.0²+19.5²) kN |
| Critical bolt resultant | 59.1 (φVf 93) kN |
| Bearing φVb | 158.4 kN |
Governing check: Critical bolt (direct + torsion) (AS 4100 §9.4), Fr 59.1 kN against φVf 92.7 kN, utilisation 0.64, passes.
Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.
Design codes
Eccentric Bolt Group works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.
| Region | Standard and edition |
|---|---|
| Australia and New Zealand | AS 4100:2020 |
| United States | ANSI/AISC 360-22 |
| Canada | CSA S16-19 |
| Europe | EN 1993-1-8:2005 |
Use it in full during the 7-day trial of the Professional plan. Paid plans give access to the module packs. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.
Related modules
- Bolt Group
Bolt group under shear plus an out-of-plane moment to AS 4100 §9 - Bolt Tension
Bolt in tension with prying to AS 4100 §9 - Weld Group
Fillet weld group under in-plane eccentric shear to AS 4100 §9.7 - Anchor Bolt
Fastening to concrete (cast-in or post-installed anchor group) to AS 5216 - Base Plate
Steel column base plate to AS 3600 §12.6 and AS 4100 - Bolts
Single high-strength bolt capacity to AS 4100 §9.3 - Cleat Plate
Fin/cleat shear connection to AS 4100 §9 - End Plate
Bolted moment end-plate connection to AS 4100 §9
Open Eccentric Bolt Group with a free account