What it checks

The flange tension force from the moment is resisted by the tension-bolt rows, the bolts are checked in shear, the end plate in yield-line flexure, and the tension-flange weld is sized for the flange force.

Inputs

End Plate takes 17 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.

InputUnitDefault
Beam
Beam section type Options: UB; UC.-UB
Beam section-410UB53.7
Actions
Design moment M*kNm120
Design shear V*kN120
Bolts
Bolt size Options: M16; M20; M24; M30.-M24
Bolt grade Options: 4.6; 8.8; 10.9.-8.8
Tension bolts (even: two per row)-4
Total bolts (even)-8
Tension rows counted Options: Rows each side of the tension flange (N_f shared equally); Every tension row, force in proportion to its lever arm (rigid plate).-Rows each side of the tension flange (N_f shared equally)
Plate
Bolt-to-flange lever afmm45
End-plate thickness timm25
Plate yield fyiMPa300
Plate width bi (0 = flange width, widened to fit the bolts)mm0
Bolt gauge s_g (0 = smallest that clears the web)mm0
Pitch of the rows inside the flanges (0 = 3d_f)mm0
End distance above the top bolt row (0 = 1.5d_f)mm0
Flange weld legmm8

Results and report

The module reports: Beam; Flange lever dEff; Flange force Nf; Tension/bolt, most loaded; Plate φMp/bolt; Flange weld capacity; Plate width / bolt gauge; Beam φMs.

It checks: Tension bolt, most loaded (per bolt); Shear bolt; Tension bolt, shear and tension combined; End-plate bending (tension flange); Tension-flange weld; Beam section moment capacity.

Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.

Example with the default inputs

End Plate with its default inputs for the Australia and New Zealand code system. The main inputs:

InputValue
Beam section typeUB
Beam section410UB53.7
Design moment M*120 kNm
Design shear V*120 kN
Bolt sizeM24
Bolt grade8.8
Tension bolts (even: two per row)4
Total bolts (even)8

Headline results:

ResultValue
Beam410UB53.7 (UB)
Flange lever dEff392 mm
Flange force Nf306.4 kN
Tension/bolt, most loaded76.6 (φNtf 234) kN
Plate φMp/bolt3755 (dem 3447) kNmm
Flange weld capacity474 kN

Governing check: End-plate bending (tension flange) (AS 4100 Cl 5.2.1 · ASI DG12), M* 3447 kNmm (Ntb·af) against φMs 3755 kNmm (b_eff 89 mm), utilisation 0.92, passes.

Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.

Design codes

End Plate works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.

RegionStandard and edition
Australia and New ZealandAS 4100:2020
United StatesANSI/AISC 360-22
CanadaCSA S16-19
EuropeEN 1993-1-8:2005

Use it in full during the 7-day trial of the Professional plan. Paid plans give access to the module packs. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.

Related modules

  • Anchor Bolt
    Fastening to concrete (cast-in or post-installed anchor group) to AS 5216
  • Base Plate
    Steel column base plate to AS 3600 §12.6 and AS 4100
  • Bolts
    Single high-strength bolt capacity to AS 4100 §9.3
  • Cleat Plate
    Fin/cleat shear connection to AS 4100 §9
  • Pins
    Pin connection to AS 4100 §9.4
  • Portal Knee
    Bolted moment end-plate at a portal-frame knee
  • Taper Haunch
    Tapered haunch at a portal-frame knee
  • Welds
    Fillet weld capacity to AS 4100 §9.7.3

All connection design modules

Open End Plate with a free account

7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.