TensorNodeStart free trial
Home / Products / Concrete design / Two-Way Slab

Two-Way Slab design check for AS 3600, ACI 318, CSA A23.3 and Eurocode 2

Two-way spanning slab supported on four edges.

Create a free account to use it

7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.

What it checks

The Grashof load share between the short and long spans, the positive span moments (and support hogging if continuous), reinforcement each way and the span/depth deflection control.

Inputs

Two-Way Slab takes 13 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.

InputUnitDefault
Geometry
Short span Lxm4
Long span Lym5
Slab depth Dmm200
Support
Edge condition Options: Simply supported; One edge continuous; Continuous (interior).-Simply supported
Loads
Dead load GkPa1.5
Live load QkPa3
Material
Concrete f'cMPa32
fsyMPa500
Reinforcement
Covermm25
X-dir bar diamm12
X-dir spacingmm200
Y-dir bar diamm12
Y-dir spacingmm250

Results and report

The module reports: X-dir k_u (short span); Aspect ratio Ly/Lx; Load share (short/long); Span moments Mx/My; Reinforcement X / Y; Span/depth Lx/d.

It checks: Aspect ratio Ly/Lx, two-way action; Span/depth (deflection); X-dir Flexural capacity (stress-block); X-dir Minimum reinforcement; X-dir Section ductility k_u (Under-reinforced (ductile)); X-dir Tension steel yielding; X-dir Maximum reinforcement; Y-dir Flexural capacity (stress-block); Y-dir Minimum reinforcement; Y-dir Section ductility k_u (Under-reinforced (ductile)).

Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.

Example with the default inputs

Two-Way Slab with its default inputs for the Australia and New Zealand code system. The main inputs:

InputValue
Short span Lx4 m
Long span Ly5 m
Slab depth D200 mm
Edge conditionSimply supported
Dead load G1.5 kPa
Live load Q3 kPa
Concrete f'c32 MPa
fsy500 MPa

Headline results:

ResultValue
X-dir k_u (short span)0.073 / Under-reinforced (ductile)
Aspect ratio Ly/Lx1.25
Load share (short/long)4.5 / 1.8 kPa
Span moments Mx/My8.9 / 5.7 kNm/m
Reinforcement X / Y565 / 452 mm²/m
Span/depth Lx/d24 (limit 30)

Governing check: Span/depth (deflection) (AS 3600 §9.4.4), Lx/d 23.7 against ≤ 30, utilisation 0.79, passes.

Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.

Design codes

Two-Way Slab works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.

RegionStandard and edition
Australia and New ZealandAS 3600:2018
United StatesACI CODE-318-25
CanadaCSA A23.3-19
EuropeEN 1992-1-1:2004+A1:2014

Use it in full during the 7-day trial of the Professional plan. Paid plans give access to the module packs. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.

Related modules

  • Beam Shear
    Reinforced-concrete beam shear to AS 3600 §8.2
  • Beam Torsion
    Reinforced-concrete beam torsion to AS 3600:2018 Cl.
  • Column Biaxial
    RC column under axial load with biaxial bending to AS 3600 §10.6.3, the P-M interaction is built by strain compatibility about each axis, with reinforcement placed on all four faces (top/bottom bars resist X-axis bending, side bars resist Y-axis bending, both
  • Column Interaction
    Rectangular reinforced-concrete column to AS 3600 §10
  • Concrete Durability and Cover
    Durability and cover to reinforcement to AS 3600:2018 Section 4
  • Concrete Wall
    RC wall in compression by the AS 3600 §11.5.3 simplified method
  • Corbel / Bracket
    Reinforced-concrete corbel / bracket to AS 3600
  • Crack Control
    Crack control for RC beams/slabs by the AS 3600 §8.6.2.2 deemed-to-comply method

All concrete design modules

Open Two-Way Slab with a free account

7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.