TensorNodeStart free trial
Home / Products / Concrete design / Concrete Durability and Cover

Concrete Durability and Cover design check for AS 3600, ACI 318, CSA A23.1 and Eurocode 2

Durability and cover to reinforcement to AS 3600:2018 Section 4.

Create a free account to use it

7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.

What it checks

Exposure classification (Table 4.3, with the sulfate and saline soil tables 4.8.1 and 4.8.2), minimum f'c and curing (Table 4.4, with the abrasion and freezing and thawing limits of Table 4.6 and.

Inputs

Concrete Durability and Cover takes 17 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.

InputUnitDefault
Exposure
Exposure of the surface that carries the cover (Table 4.3) Options: 1(a) In ground, protected by a damp-proof membrane (A1); 1(b) In ground, residential footing in non-aggressive soil (A1); 1(c) In ground, other member in non-aggressive soil (A2); 1(d)(i) Aggressive soil, sulfate bearing, Mg under 1 g/L (Table 4.8.1); 1(d)(ii) Aggressive soil, sulfate bearing, Mg 1 g/L or more (U); 1(d)(iii) Aggressive soil, other (U); 1(e) Salt-rich soil or salinity-affected area (Table 4.8.2); 2(a)(i) Interior, fully enclosed, residential (A1); +14 more.-3(b) Exterior, near-coastal (1 km to 50 km from coast), any climate (B1)
Most severe other surface of the member (sets the concrete grade) Options: Same as the surface above; 1(a) In ground, protected by a damp-proof membrane (A1); 1(b) In ground, residential footing in non-aggressive soil (A1); 1(c) In ground, other member in non-aggressive soil (A2); 1(d)(ii) Aggressive soil, sulfate bearing, Mg 1 g/L or more (U); 1(d)(iii) Aggressive soil, other (U); 2(a)(i) Interior, fully enclosed, residential (A1); 2(a)(ii) Interior, fully enclosed, non-residential (A2); +13 more.-Same as the surface above
Abrasion of the wearing surface (Table 4.6) Options: No abrasion from traffic; Footpaths and residential driveways (20 MPa); Commercial and industrial floors without vehicles (25 MPa); Pneumatic-tyred traffic (32 MPa); Non-pneumatic-tyred traffic (40 MPa); Steel-wheeled traffic (40 MPa or more, assess).-No abrasion from traffic
Freezing and thawing (Cl. 4.7) Options: Not exposed; Occasional, under 25 cycles a year (32 MPa); Frequent, 25 or more cycles a year (40 MPa).-Not exposed
Use the one grade lower concession (Cl. 4.3.2) Options: No; Yes, one exterior surface, with the bracketed cover.-No
Construction
Member type Options: Beam, column or other formed member; Slab or wall (formed); Footing or slab cast on or against the ground.-Beam, column or other formed member
Formwork and compaction Options: Standard formwork and compaction (Table 4.10.3.2); Rigid formwork, repetitive procedures, intense compaction (Table 4.10.3.3); Self-compacting concrete in rigid formwork (Table 4.10.3.3); Unformed or screeded surface (Table 4.10.3.2).-Standard formwork and compaction (Table 4.10.3.2)
Design lifeyears50
Section
Section width bmm300
Section depth hmm500
Cover to the outermost bar (stirrup, tie or main bar)mm45
Main bar size Options: N12; N16; N20; N24; N28; N32; N36.-N20
Fitment size (stirrup or tie) Options: N10; N12; N16; None (no stirrups or ties).-N10
Centre to centre spacing of the main barsmm80
Nominal maximum aggregate sizemm20
Concrete
Proposed concrete strength f'cMPa32
Continuous curing period provideddays7

Results and report

The module reports: Exposure class, cover surface; Exposure class, concrete quality; Minimum f'c; Governs the f'c requirement; Maximum w/cm; Required cover to the outermost bar; Governing reason; Cover provided, outermost bar; Cover provided, main bar.

It checks: Exposure classification; Continuous curing period; Cover to the main bar ≥ required; Fire resistance.

Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.

Example with the default inputs

Concrete Durability and Cover with its default inputs for the Australia and New Zealand code system. The main inputs:

InputValue
Exposure of the surface that carries the cover (Table 4.3)3(b) Exterior, near-coastal (1 km to 50 km from coast), any climate (B1)
Most severe other surface of the member (sets the concrete grade)Same as the surface above
Abrasion of the wearing surface (Table 4.6)No abrasion from traffic
Freezing and thawing (Cl. 4.7)Not exposed
Use the one grade lower concession (Cl. 4.3.2)No
Member typeBeam, column or other formed member
Formwork and compactionStandard formwork and compaction (Table 4.10.3.2)
Design life50 years

Headline results:

ResultValue
Exposure class, cover surfaceB1 (Table 4.3 item 3(b))
Exposure class, concrete qualityB1
Minimum f'c32 MPa
Governs the f'c requirementexposure class B1, Table 4.4
Maximum w/cmNot set in AS 3600 Section 4
Curing (Table 4.4)3 days continuous, or 20 MPa at stripping

Governing check: Concrete strength f'c ≥ minimum (exposure class B1, Table 4.4) (AS 3600:2018 Table 4.4, Cl. 4.4, Table 4.6, Cl. 4.7), 32 MPa against 32 MPa, utilisation 1.00, passes.

Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.

Design codes

Concrete Durability and Cover works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.

RegionStandard and edition
Australia and New ZealandAS 3600:2018
United StatesACI CODE-318-25
CanadaCSA A23.1-19
EuropeEN 1992-1-1:2004+A1:2014

Use it in full during the 7-day trial of the Professional plan. Paid plans give access to the module packs. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.

Related modules

  • Beam Shear
    Reinforced-concrete beam shear to AS 3600 §8.2
  • Beam Torsion
    Reinforced-concrete beam torsion to AS 3600:2018 Cl.
  • Column Biaxial
    RC column under axial load with biaxial bending to AS 3600 §10.6.3, the P-M interaction is built by strain compatibility about each axis, with reinforcement placed on all four faces (top/bottom bars resist X-axis bending, side bars resist Y-axis bending, both
  • Column Interaction
    Rectangular reinforced-concrete column to AS 3600 §10
  • Concrete Wall
    RC wall in compression by the AS 3600 §11.5.3 simplified method
  • Corbel / Bracket
    Reinforced-concrete corbel / bracket to AS 3600
  • Crack Control
    Crack control for RC beams/slabs by the AS 3600 §8.6.2.2 deemed-to-comply method
  • Deep Beam
    RC deep beam (span/depth < 2) by strut-and-tie to AS 3600 §7

All concrete design modules

Open Concrete Durability and Cover with a free account

7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.