What it checks

The design axial capacity per metre from the wall thickness, the load eccentricity and the slenderness-derived additional eccentricity, with the minimum vertical reinforcement.

Inputs

Concrete Wall takes 8 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.

InputUnitDefault
Wall
Wall thickness twmm200
Wall height Hwm3.6
Restraint Options: Braced top & bottom (k 0.75); Restrained one end (k 1.0); Cantilever (k 2.0).-Braced top & bottom (k 0.75)
Loads
Load eccentricity emm33
Axial load N*kN/m600
Material
Concrete f'cMPa32
Reinforcement
Vertical bar dia (each face)mm12
Vertical bar spacing (each face)mm200

Results and report

The module reports: Effective height Hwe; Additional ecc. ea; Slenderness Hwe/tw; Axial capacity φNu; Min vertical reo.

It checks: Axial capacity (simplified); Slenderness Hwe/tw; Min vertical reinforcement; Vertical wall reinforcement ρwv (both faces); Horizontal wall reinforcement.

Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.

Example with the default inputs

Concrete Wall with its default inputs for the Australia and New Zealand code system. The main inputs:

InputValue
Wall thickness tw200 mm
Wall height Hw3.6 m
RestraintBraced top & bottom (k 0.75)
Load eccentricity e33 mm
Axial load N*600 kN/m
Concrete f'c32 MPa
Vertical bar dia (each face)12 mm
Vertical bar spacing (each face)200 mm

Headline results:

ResultValue
Effective height Hwe2700 mm
Additional ecc. ea14.6 mm
Slenderness Hwe/tw13.5 (≤ 30)
Axial capacity φNu1638 kN/m
Min vertical reo300 mm²/m

Governing check: Slenderness Hwe/tw (AS 3600 §11.5.3), 13.5 against ≤ 30, utilisation 0.45, passes.

Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.

Design codes

Concrete Wall works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.

RegionStandard and edition
Australia and New ZealandAS 3600:2018
United StatesACI CODE-318-25
CanadaCSA A23.3-19
EuropeEN 1992-1-1:2004+A1:2014

Use it in full during the 7-day trial of the Professional plan. Paid plans give access to the module packs. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.

Related modules

  • Beam Shear
    Reinforced-concrete beam shear to AS 3600 §8.2
  • Beam Torsion
    Reinforced-concrete beam torsion to AS 3600:2018 Cl.
  • Column Biaxial
    RC column under axial load with biaxial bending to AS 3600 §10.6.3, the P-M interaction is built by strain compatibility about each axis, with reinforcement placed on all four faces (top/bottom bars resist X-axis bending, side bars resist Y-axis bending, both
  • Column Interaction
    Rectangular reinforced-concrete column to AS 3600 §10
  • Concrete Durability and Cover
    Durability and cover to reinforcement to AS 3600:2018 Section 4
  • Corbel / Bracket
    Reinforced-concrete corbel / bracket to AS 3600
  • Crack Control
    Crack control for RC beams/slabs by the AS 3600 §8.6.2.2 deemed-to-comply method
  • Deep Beam
    RC deep beam (span/depth < 2) by strut-and-tie to AS 3600 §7

All concrete design modules

Open Concrete Wall with a free account

7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.