TensorNodeStart free trial
Home / Products / Concrete design / Corbel / Bracket

Corbel / Bracket design check for AS 3600, ACI 318, CSA A23.3 and Eurocode 2

Reinforced-concrete corbel / bracket to AS 3600.

Create a free account to use it

7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.

What it checks

Shear-friction with the casting-interface condition (monolithic / roughened / smooth / against steel), main tension tie and closed ties from the vertical and horizontal actions, bearing and the maximum shear lim.

Inputs

Corbel / Bracket takes 16 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.

InputUnitDefault
Casting interface Options: Monolithic (μ 0.9); Roughened (μ 0.7); Smooth / trowelled (μ 0.6); Against rolled steel (μ 0.6).-Monolithic (μ 0.9)
Vertical load V*kN350
Horizontal load H*kN70
Shear span a_v (load to face)mm150
Effective depth dmm350
Width bwmm300
Bearing widthmm150
Concrete f'cMPa40
Steel fsyMPa500
Main tie bar diamm20
Number of main bars-4
Covermm40
Closed horizontal stirrups (pairs)-3
Stirrup dia Options: none; R10/N10; N12; N16.-R10/N10
Stirrup spacingmm100
Corbel arrangement Options: Single corbel; Double corbel (both sides, symmetric).-Single corbel

Results and report

The module reports: Casting μ; Flexural tension A_f; Direct tension A_n; Shear-friction A_vf; Main tie A_sc (req / prov); Closed ties A_h (req); Max shear φVu; a_v/d.

It checks: Closed ties provided ≥ Ah,req; Main tension tie; Max bearing-shear; Bearing stress.

Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.

Example with the default inputs

Corbel / Bracket with its default inputs for the Australia and New Zealand code system. The main inputs:

InputValue
Casting interfaceMonolithic (μ 0.9)
Vertical load V*350 kN
Horizontal load H*70 kN
Shear span a_v (load to face)150 mm
Effective depth d350 mm
Width bw300 mm
Bearing width150 mm
Concrete f'c40 MPa

Headline results:

ResultValue
Casting μ0.90 (monolithic)
Flexural tension A_f443 mm²
Direct tension A_n165 mm²
Shear-friction A_vf1111 mm²
Main tie A_sc (req / prov)905 / 1257 mm²
Closed ties A_h (req)370 mm²

Governing check: Closed ties provided ≥ Ah,req (AS 3600 §7.3 / SF §11.8), Ah 471 mm² (3×N10@100) against ≥ Ah,req 370 mm², utilisation 0.79, passes.

Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.

Design codes

Corbel / Bracket works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.

RegionStandard and edition
Australia and New ZealandAS 3600:2018
United StatesACI CODE-318-25
CanadaCSA A23.3-19
EuropeEN 1992-1-1:2004+A1:2014

Use it in full during the 7-day trial of the Professional plan. Paid plans give access to the module packs. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.

Related modules

  • Beam Shear
    Reinforced-concrete beam shear to AS 3600 §8.2
  • Beam Torsion
    Reinforced-concrete beam torsion to AS 3600:2018 Cl.
  • Column Biaxial
    RC column under axial load with biaxial bending to AS 3600 §10.6.3, the P-M interaction is built by strain compatibility about each axis, with reinforcement placed on all four faces (top/bottom bars resist X-axis bending, side bars resist Y-axis bending, both
  • Column Interaction
    Rectangular reinforced-concrete column to AS 3600 §10
  • Concrete Durability and Cover
    Durability and cover to reinforcement to AS 3600:2018 Section 4
  • Concrete Wall
    RC wall in compression by the AS 3600 §11.5.3 simplified method
  • Crack Control
    Crack control for RC beams/slabs by the AS 3600 §8.6.2.2 deemed-to-comply method
  • Deep Beam
    RC deep beam (span/depth < 2) by strut-and-tie to AS 3600 §7

All concrete design modules

Open Corbel / Bracket with a free account