Strut efficiency factor βs, diagonal-strut and bottom-tie capacities, node bearing, the diagonal-compression limit, and tie reinforcement (bar diameter and number).

Inputs

Strut & Tie takes 19 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.

InputUnitDefault
Member depth Dmm800
Width bwmm400
Load-to-support distance am0.8
Strut angle θ (0 = auto)°0
Bearing/load widthmm300
Concrete f'cMPa40
Steel fsyMPa500
Applied load P*kN400
Tie bar diametermm20
Number of tie bars-6
Cover to tiemm40
Horizontal web bars per level (2 = one each face)-2
Horizontal web bar Options: none; N10; N12; N16; N20.-N16
Horizontal bar spacingmm150
Vertical web bar legs (2 = closed link, one leg each face)-2
Vertical web bar (links) Options: none; N10; N12; N16.-N16
Vertical bar spacingmm150
Tie anchorage at the support Options: 90° cog (AS 3600 13.1.2.6, 13.1.2.7); Straight bar.-90° cog (AS 3600 13.1.2.6, 13.1.2.7)
Service load P_s for crack control (0 = P*/1.4)kN0

Results and report

The module reports: Strut angle θ; Strut efficiency βs; Strut force C; Strut capacity φC; Tie force T; Tie Ast (req / prov); Tie capacity φT; Diagonal limit; Web ρ_h / ρ_v; Bursting T*_b / φ capacity.

It checks: Bursting reinforcement, strength: φ_st·ΣA_si·f_sy·sinγ_i ≥ T*_b; Bursting reinforcement, serviceability: ΣA_si·f_si·sinγ_i ≥ max(T*_b.s, T_b.cr); Diagonal strut; Bottom tie; Diagonal-compression limit.

Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.

Example with the default inputs

Strut & Tie with its default inputs for the Australia and New Zealand code system. The main inputs:

InputValue
Member depth D800 mm
Width bw400 mm
Load-to-support distance a0.8 m
Strut angle θ (0 = auto)0 °
Bearing/load width300 mm
Concrete f'c40 MPa
Steel fsy500 MPa
Applied load P*400 kN

Headline results:

ResultValue
Strut angle θ40.2 °
Strut efficiency βs0.519
Strut force C620 kN
Strut capacity φC1311 kN
Tie force T474 kN
Tie Ast (req / prov)1115 / 1885 mm²

Governing check: Bursting reinforcement, serviceability: ΣA_si·f_si·sinγ_i ≥ max(T*_b.s, T_b.cr) (AS 3600 §7.2.4 Eq. 7.2.4(2), §12.7), 495 kN (T*_b.s 222 kN at P_s 286 kN, T_b.cr 495 kN) against 521 kN (f_si 250 MPa, moderate control), utilisation 0.95, passes.

Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.

Design codes

Strut & Tie works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.

RegionStandard and edition
Australia and New ZealandAS 3600:2018
United StatesACI CODE-318-25
CanadaCSA A23.3-19
EuropeEN 1992-1-1:2004+A1:2014

Use it in full during the 7-day trial of the Professional plan. Paid plans give access to the module packs. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.

Related modules

  • Beam Shear
    Reinforced-concrete beam shear to AS 3600 §8.2
  • Beam Torsion
    Reinforced-concrete beam torsion to AS 3600:2018 Cl.
  • Column Biaxial
    RC column under axial load with biaxial bending to AS 3600 §10.6.3, the P-M interaction is built by strain compatibility about each axis, with reinforcement placed on all four faces (top/bottom bars resist X-axis bending, side bars resist Y-axis bending, both
  • Column Interaction
    Rectangular reinforced-concrete column to AS 3600 §10
  • Concrete Durability and Cover
    Durability and cover to reinforcement to AS 3600:2018 Section 4
  • Concrete Wall
    RC wall in compression by the AS 3600 §11.5.3 simplified method
  • Corbel / Bracket
    Reinforced-concrete corbel / bracket to AS 3600
  • Crack Control
    Crack control for RC beams/slabs by the AS 3600 §8.6.2.2 deemed-to-comply method

All concrete design modules

Open Strut & Tie with a free account

7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.