What it checks

Circular or rectangular column, interior/edge/corner case, unbalanced-moment transfer, and shear-reinforcement / integrity check.

Inputs

Punching Shear takes 10 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.

InputUnitDefault
Column
Column shape Options: Rectangular; Circular.-Rectangular
Column position Options: Interior (4 sides); Edge (3 sides); Corner (2 sides).-Interior (4 sides)
Column cxmm400
Column cymm400
Slab
Slab effective depth d_ommm230
Concrete f'cMPa32
Actions
Column reaction V*kN600
Unbalanced moment M*vkNm60
Reinforcement
Shear reinforcement Options: None (concrete only); Stud/fitment shear reo.-None (concrete only)
Structural integrity bottom bars through column-Yes

Results and report

The module reports: Critical perimeter u; Column aspect βh; Concrete stress fcv; Basic capacity Vuo; Moment-transfer factor; φVu (with moment); Shear reo required?; φVu,max (with reo).

It checks: Punching shear; Structural integrity bars (bottom, through column).

Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.

Example with the default inputs

Punching Shear with its default inputs for the Australia and New Zealand code system. The main inputs:

InputValue
Column shapeRectangular
Column positionInterior (4 sides)
Column cx400 mm
Column cy400 mm
Slab effective depth d_om230 mm
Concrete f'c32 MPa
Column reaction V*600 kN
Unbalanced moment M*v60 kNm

Headline results:

ResultValue
Critical perimeter u2520 mm
Column aspect βh1.00
Concrete stress fcv1.92 MPa
Basic capacity Vuo1115 kN
Moment-transfer factor1.217
φVu (with moment)641 kN

Governing check: Punching shear (AS 3600 §9.3), V* 600.0 kN against φVu 641.0 kN, utilisation 0.94, passes.

Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.

Design codes

Punching Shear works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.

RegionStandard and edition
Australia and New ZealandAS 3600:2018
United StatesACI CODE-318-25
CanadaCSA A23.3-19
EuropeEN 1992-1-1:2004+A1:2014

Use it in full during the 7-day trial of the Professional plan. Paid plans give access to the module packs. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.

Related modules

  • Beam Shear
    Reinforced-concrete beam shear to AS 3600 §8.2
  • Beam Torsion
    Reinforced-concrete beam torsion to AS 3600:2018 Cl.
  • Column Biaxial
    RC column under axial load with biaxial bending to AS 3600 §10.6.3, the P-M interaction is built by strain compatibility about each axis, with reinforcement placed on all four faces (top/bottom bars resist X-axis bending, side bars resist Y-axis bending, both
  • Column Interaction
    Rectangular reinforced-concrete column to AS 3600 §10
  • Concrete Durability and Cover
    Durability and cover to reinforcement to AS 3600:2018 Section 4
  • Concrete Wall
    RC wall in compression by the AS 3600 §11.5.3 simplified method
  • Corbel / Bracket
    Reinforced-concrete corbel / bracket to AS 3600
  • Crack Control
    Crack control for RC beams/slabs by the AS 3600 §8.6.2.2 deemed-to-comply method

All concrete design modules

Open Punching Shear with a free account

7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.