Plain Concrete design check for AS 3600, ACI 318, CSA A23.3 and Eurocode 2
Plain Concrete is a module of the concrete group, for Australia and New Zealand, United States, Canada and Europe.
Create a free account to use it
7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.
What it checks
Plain (unreinforced) concrete member to AS 3600 §20, a rectangular member of width b, depth D and bearing length L set by the user.
Inputs
Plain Concrete takes 8 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.
| Input | Unit | Default |
|---|---|---|
| Section | ||
| Section width b | mm | 1000 |
| Section depth D | mm | 300 |
| Span / length L (0 = enter M* directly) | m | 0 |
| Material | ||
| Concrete f'c | MPa | 25 |
| Actions | ||
| Applied UDL w (if span>0) | kN/m | 15 |
| Applied moment M* (used if span=0) | kNm | 10 |
| Axial / bearing N* | kN | 200 |
| Bearing (contact) area A_b under the load, 0 = no bearing check | mm² | 0 |
Results and report
The module reports: Applied moment M* (from span or user input).
It checks: Flexural tension (unreinforced).
Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.
Example with the default inputs
Plain Concrete with its default inputs for the Australia and New Zealand code system. The main inputs:
| Input | Value |
|---|---|
| Section width b | 1000 mm |
| Section depth D | 300 mm |
| Span / length L (0 = enter M* directly) | 0 m |
| Concrete f'c | 25 MPa |
| Applied UDL w (if span>0) | 15 kN/m |
| Applied moment M* (used if span=0) | 10 kNm |
| Axial / bearing N* | 200 kN |
| Bearing (contact) area A_b under the load, 0 = no bearing check | 0 mm² |
Headline results:
| Result | Value |
|---|---|
| Section modulus Z = b·D²/6 | 15000 ×10³ mm³ |
| Flexural tensile strength f'ct.f = 0.6√f'c | 3.00 MPa |
| Flexural capacity φMu = φ·f′ct.f·Z (φ = 0.6) | 27.0 kNm |
| Applied moment M* (from span or user input) | 10.0 kNm |
Governing check: Flexural tension (unreinforced) (AS 3600 §20.2), M* 10.0 kNm against φMu 27.0 kNm, utilisation 0.37, passes.
Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.
Design codes
Plain Concrete works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.
| Region | Standard and edition |
|---|---|
| Australia and New Zealand | AS 3600:2018 |
| United States | ACI CODE-318-25 |
| Canada | CSA A23.3-19 |
| Europe | EN 1992-1-1:2004+A1:2014 |
Use it in full during the 7-day trial of the Professional plan. Paid plans give access to the module packs. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.
Related modules
- Beam Shear
Reinforced-concrete beam shear to AS 3600 §8.2 - Beam Torsion
Reinforced-concrete beam torsion to AS 3600:2018 Cl. - Column Biaxial
RC column under axial load with biaxial bending to AS 3600 §10.6.3, the P-M interaction is built by strain compatibility about each axis, with reinforcement placed on all four faces (top/bottom bars resist X-axis bending, side bars resist Y-axis bending, both - Column Interaction
Rectangular reinforced-concrete column to AS 3600 §10 - Concrete Durability and Cover
Durability and cover to reinforcement to AS 3600:2018 Section 4 - Concrete Wall
RC wall in compression by the AS 3600 §11.5.3 simplified method - Corbel / Bracket
Reinforced-concrete corbel / bracket to AS 3600 - Crack Control
Crack control for RC beams/slabs by the AS 3600 §8.6.2.2 deemed-to-comply method
Open Plain Concrete with a free account
7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.