TensorNodeStart free trial
Home / Products / Concrete design / Flat Slab

Flat Slab design check for AS 3600, ACI 318, CSA A23.3 and Eurocode 2

Flat slab (column-supported, no beams) by the Direct Design Method.

Create a free account to use it

7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.

What it checks

The total static moment per panel, its negative/positive split, the column-strip and middle-strip distribution in both directions, and the top and bottom reinforcement (bar diameter and spacin.

Inputs

Flat Slab takes 16 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.

InputUnitDefault
Geometry
Panel span L_x (c/c)m6
Panel span L_y (c/c)m6
Column size (X)mm400
Column size (Y)mm400
Slab thickness Dmm250
Covermm25
Material
Concrete f'cMPa32
Steel fsyMPa500
Loads
Dead load GkPa6
Live load QkPa3
Span type Options: Interior span; End span.-Interior span
Top layer
Top (negative) bar diamm16
Top bar spacingmm150
Bottom layer
Bottom (positive) bar diamm12
Bottom bar spacingmm200
Column capital
Column capital Options: None; Capital at each column.-None

Results and report

The module reports: Design load w (ULS); Column-strip −M (X); Column-strip +M (X); Provided top / bottom (X CS); Column reaction V* (punching); Span/depth Lₙ/d.

It checks: Column-strip top steel (X): negative M; Column-strip bottom steel (X): positive M; Minimum reinforcement (column strip); Span/effective-depth (serviceability); Column reaction → punching demand; Total static moment Mo (X); CS-top Flexural capacity (stress-block); CS-top Minimum reinforcement; CS-top Section ductility k_u (Under-reinforced (ductile)); CS-top Tension steel yielding.

Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.

Example with the default inputs

Flat Slab with its default inputs for the Australia and New Zealand code system. The main inputs:

InputValue
Panel span L_x (c/c)6 m
Panel span L_y (c/c)6 m
Column size (X)400 mm
Column size (Y)400 mm
Slab thickness D250 mm
Cover25 mm
Concrete f'c32 MPa
Steel fsy500 MPa

Headline results:

ResultValue
Design load w (ULS)11.7 kPa
Total static moment Mo(X) = w·Lt·Lo²/8287.1 kNm: distributed to col-strip (−65% / +35%) and mid-strip
Column-strip −M (X)140.0 → 1651 mm²
Column-strip +M (X)60.3 → 1395 mm²
Provided top / bottom (X CS)4021 / 1696 mm²
Column reaction V* (punching)421 kN

Governing check: Span/effective-depth (serviceability) (AS 3600 §9.3.4), L_n/d 26.4 against ≈ 28 limit, utilisation 0.94, passes.

Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.

Design codes

Flat Slab works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.

RegionStandard and edition
Australia and New ZealandAS 3600:2018
United StatesACI CODE-318-25
CanadaCSA A23.3-19
EuropeEN 1992-1-1:2004+A1:2014

Use it in full during the 7-day trial of the Professional plan. Paid plans give access to the module packs. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.

Related modules

  • Beam Shear
    Reinforced-concrete beam shear to AS 3600 §8.2
  • Beam Torsion
    Reinforced-concrete beam torsion to AS 3600:2018 Cl.
  • Column Biaxial
    RC column under axial load with biaxial bending to AS 3600 §10.6.3, the P-M interaction is built by strain compatibility about each axis, with reinforcement placed on all four faces (top/bottom bars resist X-axis bending, side bars resist Y-axis bending, both
  • Column Interaction
    Rectangular reinforced-concrete column to AS 3600 §10
  • Concrete Durability and Cover
    Durability and cover to reinforcement to AS 3600:2018 Section 4
  • Concrete Wall
    RC wall in compression by the AS 3600 §11.5.3 simplified method
  • Corbel / Bracket
    Reinforced-concrete corbel / bracket to AS 3600
  • Crack Control
    Crack control for RC beams/slabs by the AS 3600 §8.6.2.2 deemed-to-comply method

All concrete design modules

Open Flat Slab with a free account

7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.