What it checks
The total static moment per panel, its negative/positive split, the column-strip and middle-strip distribution in both directions, and the top and bottom reinforcement (bar diameter and spacin.
Inputs
Flat Slab takes 16 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.
| Input | Unit | Default |
|---|---|---|
| Geometry | ||
| Panel span L_x (c/c) | m | 6 |
| Panel span L_y (c/c) | m | 6 |
| Column size (X) | mm | 400 |
| Column size (Y) | mm | 400 |
| Slab thickness D | mm | 250 |
| Cover | mm | 25 |
| Material | ||
| Concrete f'c | MPa | 32 |
| Steel fsy | MPa | 500 |
| Loads | ||
| Dead load G | kPa | 6 |
| Live load Q | kPa | 3 |
| Span type Options: Interior span; End span. | - | Interior span |
| Top layer | ||
| Top (negative) bar dia | mm | 16 |
| Top bar spacing | mm | 150 |
| Bottom layer | ||
| Bottom (positive) bar dia | mm | 12 |
| Bottom bar spacing | mm | 200 |
| Column capital | ||
| Column capital Options: None; Capital at each column. | - | None |
Results and report
The module reports: Design load w (ULS); Column-strip −M (X); Column-strip +M (X); Provided top / bottom (X CS); Column reaction V* (punching); Span/depth Lₙ/d.
It checks: Column-strip top steel (X): negative M; Column-strip bottom steel (X): positive M; Minimum reinforcement (column strip); Span/effective-depth (serviceability); Column reaction → punching demand; Total static moment Mo (X); CS-top Flexural capacity (stress-block); CS-top Minimum reinforcement; CS-top Section ductility k_u (Under-reinforced (ductile)); CS-top Tension steel yielding.
Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.
Example with the default inputs
Flat Slab with its default inputs for the Australia and New Zealand code system. The main inputs:
| Input | Value |
|---|---|
| Panel span L_x (c/c) | 6 m |
| Panel span L_y (c/c) | 6 m |
| Column size (X) | 400 mm |
| Column size (Y) | 400 mm |
| Slab thickness D | 250 mm |
| Cover | 25 mm |
| Concrete f'c | 32 MPa |
| Steel fsy | 500 MPa |
Headline results:
| Result | Value |
|---|---|
| Design load w (ULS) | 11.7 kPa |
| Total static moment Mo(X) = w·Lt·Lo²/8 | 287.1 kNm: distributed to col-strip (−65% / +35%) and mid-strip |
| Column-strip −M (X) | 140.0 → 1651 mm² |
| Column-strip +M (X) | 60.3 → 1395 mm² |
| Provided top / bottom (X CS) | 4021 / 1696 mm² |
| Column reaction V* (punching) | 421 kN |
Governing check: Span/effective-depth (serviceability) (AS 3600 §9.3.4), L_n/d 26.4 against ≈ 28 limit, utilisation 0.94, passes.
Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.
Design codes
Flat Slab works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.
| Region | Standard and edition |
|---|---|
| Australia and New Zealand | AS 3600:2018 |
| United States | ACI CODE-318-25 |
| Canada | CSA A23.3-19 |
| Europe | EN 1992-1-1:2004+A1:2014 |
Use it in full during the 7-day trial of the Professional plan. Paid plans give access to the module packs. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.
Related modules
- Beam Shear
Reinforced-concrete beam shear to AS 3600 §8.2 - Beam Torsion
Reinforced-concrete beam torsion to AS 3600:2018 Cl. - Column Biaxial
RC column under axial load with biaxial bending to AS 3600 §10.6.3, the P-M interaction is built by strain compatibility about each axis, with reinforcement placed on all four faces (top/bottom bars resist X-axis bending, side bars resist Y-axis bending, both - Column Interaction
Rectangular reinforced-concrete column to AS 3600 §10 - Concrete Durability and Cover
Durability and cover to reinforcement to AS 3600:2018 Section 4 - Concrete Wall
RC wall in compression by the AS 3600 §11.5.3 simplified method - Corbel / Bracket
Reinforced-concrete corbel / bracket to AS 3600 - Crack Control
Crack control for RC beams/slabs by the AS 3600 §8.6.2.2 deemed-to-comply method
Open Flat Slab with a free account
7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.