Timber Roof Beam design check for AS 1720.1, AWC NDS, CSA O86 and Eurocode 5
Timber roof beam/rafter to AS 1720.1.
Create a free account to use it
7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.
What it checks
Gravity (G + Q) and wind (including net uplift) load cases, bending with k12, shear, and deflection.
Inputs
Timber Roof Beam takes 11 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.
| Input | Unit | Default |
|---|---|---|
| Material | ||
| Stress grade Options: Custom (enter f-values); F7 KD Pine. | - | Custom (enter f-values) |
| Bending f'b | MPa | 17 |
| Shear f's | MPa | 2.6 |
| Modulus E | MPa | 10000 |
| Section | ||
| Depth d | mm | 190 |
| Breadth b | mm | 45 |
| Geometry | ||
| Span L | m | 3 |
| Loads | ||
| Dead load G | kPa | 0.4 |
| Roof live Q | kPa | 0.25 |
| Wind (down) W | kPa | 0.5 |
| Beam spacing | m | 0.9 |
Results and report
The module reports: Section; Governing load w*; Moment M*; Uplift governs?; Deflection.
It checks: Deflection (G + creep, W).
Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.
Example with the default inputs
Timber Roof Beam with its default inputs for the Australia and New Zealand code system. The main inputs:
| Input | Value |
|---|---|
| Stress grade | Custom (enter f-values) |
| Bending f'b | 17 MPa |
| Shear f's | 2.6 MPa |
| Modulus E | 10000 MPa |
| Depth d | 190 mm |
| Breadth b | 45 mm |
| Span L | 3 m |
| Dead load G | 0.4 kPa |
Headline results:
| Result | Value |
|---|---|
| Section | 190 × 45 mm |
| Governing load w* | 0.88 kN/m |
| Moment M* | 1.0 (φMb 1.7) kNm |
| Uplift governs? | No |
| Deflection | 4.8 (L/250 12.0) mm |
Governing check: Bending (AS 1720.1 §3.2), M* 1.0 kNm against φMb 1.7 kNm, utilisation 0.59, passes.
Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.
Design codes
Timber Roof Beam works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.
| Region | Standard and edition |
|---|---|
| Australia and New Zealand | AS 1720.1:2010 |
| United States | ANSI/AWC NDS-2018 |
| Canada | CSA O86-19 |
| Europe | EN 1995-1-1:2004+A2:2014, EN 1990:2002+A1:2005 |
Use it in full during the 7-day trial of the Professional plan. Paid plans give access to the module packs. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.
Related modules
- Circular Column
Circular timber column / pole to AS 1720.1 §3.3 - F17 Span Tables
Maximum span for an F-grade timber member - Joint
Timber joint (bolted / nailed / screwed) lateral capacity to AS 1720.1 §4 - Timber Column
Timber column/post to AS 1720.1 §3.3 - Timber Floor Beam
Sawn/LVL timber floor beam to AS 1720.1 - Timber Member
Sawn / glulam rectangular timber member to AS 1720.1 - Timber Member in Fire
Fire resistance of a timber beam or column to AS 1720.4 by the residual section method
Open Timber Roof Beam with a free account
7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.