Timber Floor Beam design check for AS 1720.1, AWC NDS, CSA O86 and Eurocode 5
Sawn/LVL timber floor beam to AS 1720.1.
Create a free account to use it
7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.
What it checks
Bending with lateral-stability k12, shear, and the creep-affected total deflection plus the live-load deflection.
Inputs
Timber Floor Beam takes 10 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.
| Input | Unit | Default |
|---|---|---|
| Material | ||
| Stress grade Options: Custom (enter f-values); F7 KD Pine. | - | Custom (enter f-values) |
| Bending f'b | MPa | 17 |
| Shear f's | MPa | 2.6 |
| Modulus E | MPa | 10000 |
| Section | ||
| Depth d | mm | 240 |
| Breadth b | mm | 45 |
| Geometry | ||
| Span L | m | 3 |
| Loads | ||
| Dead load G | kPa | 0.6 |
| Live load Q | kPa | 1.5 |
| Beam spacing | m | 0.45 |
Results and report
The module reports: Section; Factored load w*; Moment M*; Live deflection; Total deflection.
It checks: Live deflection; Total deflection (incl. creep).
Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.
Example with the default inputs
Timber Floor Beam with its default inputs for the Australia and New Zealand code system. The main inputs:
| Input | Value |
|---|---|
| Stress grade | Custom (enter f-values) |
| Bending f'b | 17 MPa |
| Shear f's | 2.6 MPa |
| Modulus E | 10000 MPa |
| Depth d | 240 mm |
| Breadth b | 45 mm |
| Span L | 3 m |
| Dead load G | 0.6 kPa |
Headline results:
| Result | Value |
|---|---|
| Section | 240 × 45 mm |
| Factored load w* | 1.34 kN/m |
| Moment M* | 1.5 (φMb 1.8) kNm |
| Live deflection | 1.4 (L/360 8.3) mm |
| Total deflection | 2.5 (L/250 12.0) mm |
Governing check: Bending (AS 1720.1 §3.2), M* 1.5 kNm against φMb 1.8 kNm, utilisation 0.84, passes.
Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.
Design codes
Timber Floor Beam works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.
| Region | Standard and edition |
|---|---|
| Australia and New Zealand | AS 1720.1:2010 |
| United States | ANSI/AWC NDS-2018 |
| Canada | CSA O86-19 |
| Europe | EN 1995-1-1:2004+A2:2014, EN 1990:2002+A1:2005 |
Use it in full during the 7-day trial of the Professional plan. Paid plans give access to the module packs. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.
Related modules
- Circular Column
Circular timber column / pole to AS 1720.1 §3.3 - F17 Span Tables
Maximum span for an F-grade timber member - Joint
Timber joint (bolted / nailed / screwed) lateral capacity to AS 1720.1 §4 - Timber Column
Timber column/post to AS 1720.1 §3.3 - Timber Member
Sawn / glulam rectangular timber member to AS 1720.1 - Timber Roof Beam
Timber roof beam/rafter to AS 1720.1 - Timber Member in Fire
Fire resistance of a timber beam or column to AS 1720.4 by the residual section method
Open Timber Floor Beam with a free account
7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.