Timber Member design check for AS 1720.1, AWC NDS, CSA O86 and Eurocode 5
Sawn / glulam rectangular timber member to AS 1720.1.
Create a free account to use it
7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.
What it checks
Bending, shear, compression, tension and combined actions, with the k-factor capacity model and slenderness (k12) stability.
Inputs
Timber Member takes 21 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.
| Input | Unit | Default |
|---|---|---|
| Material | ||
| Stress grade Options: F7 KD Pine (validated library); Custom: enter strengths. | - | Custom: enter strengths |
| Bending f'b | MPa | 42 |
| Compression f'c | MPa | 34 |
| Tension f't | MPa | 23.1 |
| Shear f's | MPa | 3.6 |
| Capacity factor φ | - | 0.85 |
| Section | ||
| Depth d | mm | 240 |
| Breadth b | mm | 45 |
| Factors | ||
| Load duration k1 | - | 0.8 |
| Seasoning k4 | - | 1 |
| Temperature k6 | - | 1 |
| Strength sharing k9 | - | 1 |
| Material const ρb | - | 0.98 |
| Material const ρc | - | 1.083 |
| Restraint factor g13 | - | 1 |
| Restraint | ||
| Bending restraint Lay | mm | 900 |
| Compression length Lax | mm | 3600 |
| Actions | ||
| Moment M* | kNm | 4 |
| Shear V* | kN | 2 |
| Compression N*c | kN | 0 |
| Tension N*t | kN | 0 |
Results and report
The module reports: Grade; Section b × d; Section modulus Z; Bending φMb; Shear φV; Compression φNc; Tension φNt.
Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.
Example with the default inputs
Timber Member with its default inputs for the Australia and New Zealand code system. The main inputs:
| Input | Value |
|---|---|
| Stress grade | Custom: enter strengths |
| Bending f'b | 42 MPa |
| Compression f'c | 34 MPa |
| Tension f't | 23.1 MPa |
| Shear f's | 3.6 MPa |
| Capacity factor φ | 0.85 |
| Depth d | 240 mm |
| Breadth b | 45 mm |
Headline results:
| Result | Value |
|---|---|
| Grade | Custom: enter characteristic strengths |
| Section b × d | 45 × 240 mm |
| Section modulus Z | 4.32×10⁵ mm³ |
| k12 (bending / comp.) | 0.867 / 0.426 |
| Bending φMb | 10.7 kNm |
| Shear φV | 17.6 kN |
Governing check: Bending (AS 1720.1 §3.2), M* 4.0 kNm against φMb 10.7 kNm, utilisation 0.37, passes.
Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.
Design codes
Timber Member works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.
| Region | Standard and edition |
|---|---|
| Australia and New Zealand | AS 1720.1:2010 |
| United States | ANSI/AWC NDS-2018 |
| Canada | CSA O86-19 |
| Europe | EN 1995-1-1:2004+A2:2014, EN 1990:2002+A1:2005 |
This module is one of the 21 basic calculators of the Free plan (one code system, reports carry an Evaluation mark), and it opens fully during the 7-day trial. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.
Related modules
- Circular Column
Circular timber column / pole to AS 1720.1 §3.3 - F17 Span Tables
Maximum span for an F-grade timber member - Joint
Timber joint (bolted / nailed / screwed) lateral capacity to AS 1720.1 §4 - Timber Column
Timber column/post to AS 1720.1 §3.3 - Timber Floor Beam
Sawn/LVL timber floor beam to AS 1720.1 - Timber Roof Beam
Timber roof beam/rafter to AS 1720.1 - Timber Member in Fire
Fire resistance of a timber beam or column to AS 1720.4 by the residual section method
Open Timber Member with a free account
7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.