TensorNodeStart free trial
Home / Products / Timber design / Timber Column

Timber Column design check for AS 1720.1, AWC NDS, CSA O86 and Eurocode 5

Timber column/post to AS 1720.1 §3.3.

Create a free account to use it

7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.

What it checks

Axial compression with the slenderness stability factor k12 about both axes; the worse axis governs.

Inputs

Timber Column takes 9 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.

InputUnitDefault
Material
Stress grade Options: Custom (enter f-values); F7 KD Pine.-Custom (enter f-values)
Compression f'cMPa18
Bending f'bMPa17
Section
Depth dmm140
Breadth bmm140
Geometry
Heightm2.7
Effective length ke Options: Pinned (1.0); Fixed-pinned (0.85); Fixed-fixed (0.7); Cantilever (2.0).-Pinned (1.0)
Actions
Axial compression N*ckN40
Moment M* (optional)kNm0

Results and report

The module reports: Section; Effective length Le; Slenderness S (gov); Compression φNc.

It checks: Compression; Combined bending+compression.

Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.

Example with the default inputs

Timber Column with its default inputs for the Australia and New Zealand code system. The main inputs:

InputValue
Stress gradeCustom (enter f-values)
Compression f'c18 MPa
Bending f'b17 MPa
Depth d140 mm
Breadth b140 mm
Height2.7 m
Effective length kePinned (1.0)
Axial compression N*c40 kN

Headline results:

ResultValue
Section140 × 140 mm
Effective length Le2700 mm
Slenderness S (gov)19.3
Stability factor k120.54
Compression φNc128.5 kN

Governing check: Compression (AS 1720.1 §3.3), N*c 40.0 kN against φNc 128.5 kN, utilisation 0.31, passes.

Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.

Design codes

Timber Column works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.

RegionStandard and edition
Australia and New ZealandAS 1720.1:2010
United StatesANSI/AWC NDS-2018
CanadaCSA O86-19
EuropeEN 1995-1-1:2004+A2:2014, EN 1990:2002+A1:2005

This module is one of the 21 basic calculators of the Free plan (one code system, reports carry an Evaluation mark), and it opens fully during the 7-day trial. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.