Timber Column design check for AS 1720.1, AWC NDS, CSA O86 and Eurocode 5
Timber column/post to AS 1720.1 §3.3.
Create a free account to use it
7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.
What it checks
Axial compression with the slenderness stability factor k12 about both axes; the worse axis governs.
Inputs
Timber Column takes 9 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.
| Input | Unit | Default |
|---|---|---|
| Material | ||
| Stress grade Options: Custom (enter f-values); F7 KD Pine. | - | Custom (enter f-values) |
| Compression f'c | MPa | 18 |
| Bending f'b | MPa | 17 |
| Section | ||
| Depth d | mm | 140 |
| Breadth b | mm | 140 |
| Geometry | ||
| Height | m | 2.7 |
| Effective length ke Options: Pinned (1.0); Fixed-pinned (0.85); Fixed-fixed (0.7); Cantilever (2.0). | - | Pinned (1.0) |
| Actions | ||
| Axial compression N*c | kN | 40 |
| Moment M* (optional) | kNm | 0 |
Results and report
The module reports: Section; Effective length Le; Slenderness S (gov); Compression φNc.
It checks: Compression; Combined bending+compression.
Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.
Example with the default inputs
Timber Column with its default inputs for the Australia and New Zealand code system. The main inputs:
| Input | Value |
|---|---|
| Stress grade | Custom (enter f-values) |
| Compression f'c | 18 MPa |
| Bending f'b | 17 MPa |
| Depth d | 140 mm |
| Breadth b | 140 mm |
| Height | 2.7 m |
| Effective length ke | Pinned (1.0) |
| Axial compression N*c | 40 kN |
Headline results:
| Result | Value |
|---|---|
| Section | 140 × 140 mm |
| Effective length Le | 2700 mm |
| Slenderness S (gov) | 19.3 |
| Stability factor k12 | 0.54 |
| Compression φNc | 128.5 kN |
Governing check: Compression (AS 1720.1 §3.3), N*c 40.0 kN against φNc 128.5 kN, utilisation 0.31, passes.
Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.
Design codes
Timber Column works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.
| Region | Standard and edition |
|---|---|
| Australia and New Zealand | AS 1720.1:2010 |
| United States | ANSI/AWC NDS-2018 |
| Canada | CSA O86-19 |
| Europe | EN 1995-1-1:2004+A2:2014, EN 1990:2002+A1:2005 |
This module is one of the 21 basic calculators of the Free plan (one code system, reports carry an Evaluation mark), and it opens fully during the 7-day trial. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.
Related modules
- Circular Column
Circular timber column / pole to AS 1720.1 §3.3 - F17 Span Tables
Maximum span for an F-grade timber member - Joint
Timber joint (bolted / nailed / screwed) lateral capacity to AS 1720.1 §4 - Timber Floor Beam
Sawn/LVL timber floor beam to AS 1720.1 - Timber Member
Sawn / glulam rectangular timber member to AS 1720.1 - Timber Roof Beam
Timber roof beam/rafter to AS 1720.1 - Timber Member in Fire
Fire resistance of a timber beam or column to AS 1720.4 by the residual section method
Open Timber Column with a free account
7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.