TensorNodeStart free trial
Home / Products / Timber design / Circular Column

Circular Column design check for AS 1720.1, AWC NDS, CSA O86 and Eurocode 5

Circular timber column / pole to AS 1720.1 §3.3.

Create a free account to use it

7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.

What it checks

Axial compression with the slenderness stability factor k12 on the round section, plus optional bending (no lateral-torsional buckling for a circular section).

Inputs

Circular Column takes 7 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.

InputUnitDefault
Section
Diametermm200
Material
Compression f'cMPa18
Bending f'bMPa17
Geometry
Heightm3
Effective length ke Options: Pinned (1.0); Fixed-pinned (0.85); Fixed-fixed (0.7); Cantilever (2.0).-Pinned (1.0)
Actions
Axial compression N*ckN60
Moment M* (optional)kNm2

Results and report

The module reports: Area / modulus; Effective length Le; Slenderness S; φNc / φMb.

It checks: Compression.

Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.

Example with the default inputs

Circular Column with its default inputs for the Australia and New Zealand code system. The main inputs:

InputValue
Diameter200 mm
Compression f'c18 MPa
Bending f'b17 MPa
Height3 m
Effective length kePinned (1.0)
Axial compression N*c60 kN
Moment M* (optional)2 kNm

Headline results:

ResultValue
Area / modulus31416 mm² / 7.85×10⁵ mm³
Effective length Le3000 mm
Slenderness S17.3
Stability factor k120.63
φNc / φMb243.8 / 9.1 kN, kNm

Governing check: Combined (AS 1720.1 §3.5), M*/φMb + N*/φNc against ≤ 1.0, utilisation 0.47, passes.

Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.

Design codes

Circular Column works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.

RegionStandard and edition
Australia and New ZealandAS 1720.1:2010
United StatesANSI/AWC NDS-2018
CanadaCSA O86-19
EuropeEN 1995-1-1:2004+A2:2014, EN 1990:2002+A1:2005

Use it in full during the 7-day trial of the Professional plan. Paid plans give access to the module packs. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.

Related modules

All timber design modules

Open Circular Column with a free account

7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.