F17 Span Tables design check for AS 1720.1, AWC NDS, CSA O86 and Eurocode 5
Maximum span for an F-grade timber member.
Create a free account to use it
7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.
What it checks
The bending-limited span (φMb = wL²/8) and the deflection-limited span (δ = L/limit) for a chosen section, spacing and load; the lesser governs.
Inputs
F17 Span Tables takes 8 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.
| Input | Unit | Default |
|---|---|---|
| Stress grade Options: F17; F14; F11; F8; F7. | - | F17 |
| Breadth b | mm | 45 |
| Depth d | mm | 190 |
| Member spacing | mm | 450 |
| Area load (G+Q service) | kPa | 2 |
| Permanent share of the service load G/(G+Q) | - | 0.3 |
| Deflection limit L/n, n = | - | 300 |
| Duration factor k1 | - | 0.8 |
Results and report
The module reports: Grade strengths; Bending capacity φMb; Bending-limited span; Deflection-limited span; Governing max span.
It checks: Bending-limited span; Deflection-limited span; Governing maximum span.
Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.
Example with the default inputs
F17 Span Tables with its default inputs for the Australia and New Zealand code system. The main inputs:
| Input | Value |
|---|---|
| Stress grade | F17 |
| Breadth b | 45 mm |
| Depth d | 190 mm |
| Member spacing | 450 mm |
| Area load (G+Q service) | 2 kPa |
| Permanent share of the service load G/(G+Q) | 0.3 |
| Deflection limit L/n, n = | 300 |
| Duration factor k1 | 0.8 |
Headline results:
| Result | Value |
|---|---|
| Grade strengths | f'b 42 / E 14000 MPa |
| Bending capacity φMb | 7.73 kNm |
| Bending-limited span | 6.98 m |
| Deflection-limited span | 4.68 m |
| Governing max span | 4.68 (Deflection) m |
Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.
Design codes
F17 Span Tables works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.
| Region | Standard and edition |
|---|---|
| Australia and New Zealand | AS 1720.1:2010 |
| United States | ANSI/AWC NDS-2018, IRC 2018 |
| Canada | CSA O86-19, NBC 2020 |
| Europe | EN 1995-1-1:2004+A2:2014, EN 1990:2002+A1:2005 |
Use it in full during the 7-day trial of the Professional plan. Paid plans give access to the module packs. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.
Related modules
- Circular Column
Circular timber column / pole to AS 1720.1 §3.3 - Joint
Timber joint (bolted / nailed / screwed) lateral capacity to AS 1720.1 §4 - Timber Column
Timber column/post to AS 1720.1 §3.3 - Timber Floor Beam
Sawn/LVL timber floor beam to AS 1720.1 - Timber Member
Sawn / glulam rectangular timber member to AS 1720.1 - Timber Roof Beam
Timber roof beam/rafter to AS 1720.1 - Timber Member in Fire
Fire resistance of a timber beam or column to AS 1720.4 by the residual section method
Open F17 Span Tables with a free account