Tension Member design check for AS 4100, AISC 360, CSA S16 and Eurocode 3
Axially-loaded steel tension member to AS 4100 §7.2.
Create a free account to use it
7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.
What it checks
Gross-section yield and net-section fracture, including the end-connection eccentricity factor kt and net-area (bolt-hole) reduction.
Inputs
Tension Member takes 6 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.
| Input | Unit | Default |
|---|---|---|
| Section | ||
| Section type Options: EA; UEA; PFC; UB; UC; SHS; RHS; CHS. | - | UEA |
| Section | - | 150 x 100 x 12 UA |
| Connection | ||
| End connection Options: Through one element: angle by one leg (UEA long leg), channel by the web, I-section by both flanges; Unequal angle by the short leg; Every element connected (Clause 7.3.1). | - | Through one element: angle by one leg (UEA long leg), channel by the web, I-section by both flanges |
| Correction factor kt Options: From the connection (Table 7.3.2); 1.0; 0.90; 0.85; 0.75. | - | From the connection (Table 7.3.2) |
| Net-area reduction (bolt holes) | % | 12 |
| Actions | ||
| Axial tension N* | kN | 600 |
Results and report
The module reports: Section; Gross area Ag; Net area An; Capacity φNt.
It checks: Gross-section yield; Net-section fracture.
Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.
Example with the default inputs
Tension Member with its default inputs for the Australia and New Zealand code system. The main inputs:
| Input | Value |
|---|---|
| Section type | UEA |
| Section | 150 x 100 x 12 UA |
| End connection | Through one element: angle by one leg (UEA long leg), channel by the web, I-section by both flanges |
| Correction factor kt | From the connection (Table 7.3.2) |
| Net-area reduction (bolt holes) | 12 % |
| Axial tension N* | 600 kN |
Headline results:
| Result | Value |
|---|---|
| Section | 150 x 100 x 12 UA (UEA) |
| Gross area Ag | 2870 mm² |
| Net area An | 2526 mm² |
| Gross-yield 0.9·Ag·fy | 775 kN |
| Net-fracture 0.9·0.85·kt·An·fu | 723 kN |
| Capacity φNt | 723 kN |
Governing check: Net-section fracture (AS 4100 §7.2), N* 600 kN against 0.9·0.85·kt·An·fu 723 kN, utilisation 0.83, passes.
Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.
Design codes
Tension Member works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.
| Region | Standard and edition |
|---|---|
| Australia and New Zealand | AS 4100:2020 |
| United States | ANSI/AISC 360-22 |
| Canada | CSA S16-19 |
| Europe | EN 1993-1-1:2005+A1:2014, EN 1990:2002+A1:2005, EN 1993-1-8:2005 |
This module is one of the 21 basic calculators of the Free plan (one code system, reports carry an Evaluation mark), and it opens fully during the 7-day trial. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.
Related modules
- Beam-Column
Steel member under combined axial compression and bending to AS 4100 §8 - Compression Strut
Axially-loaded steel member (strut / column) to AS 4100 - Crane Beam
Overhead-crane runway beam - Floor Beam
Simply-supported steel floor beam to AS 4100 - Load Stiffener
Load-bearing web stiffener to AS 4100 §5.14 - Mullion
Steel wall mullion / wind post to AS 4100 - PFC & Plate
Built-up beam from a PFC (parallel-flange channel) with a welded plate - Portal Frame
Single-bay portal frame to AS 4100
Open Tension Member with a free account
7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.