TensorNodeStart free trial
Home / Products / Steel design / Crane Beam

Crane Beam design check for AS 4100, AISC 360, CSA S16 and Eurocode 3

Overhead-crane runway beam.

Create a free account to use it

7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.

What it checks

Moving wheel loads positioned for the absolute-maximum moment and reaction (with impact), lateral surge on the top flange, and AS 4100 bending/shear/combined capacity.

Inputs

Crane Beam takes 13 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.

InputUnitDefault
Section
Section type Options: UB; UC; PFC; UBP; Welded girder.-UB
Section-610UB125
Geometry
Runway span Lm6
Crane
Max static wheel loadkN80
Wheels on span-2
Wheel spacingm3
Impact factor-1.1
Lateral surge%10
Restraint
Top-flange segment length l between lateral restraints (0 = span)m0
Load height factor k_l Options: 1.4: wheel load on the top flange (Table 5.6.3(B)); 1.0: load at the shear centre.-1.4: wheel load on the top flange (Table 5.6.3(B))
Twist restraint factor k_t (Table 5.6.3(A))-1
Lateral rotation restraint factor k_r (Table 5.6.3(C))-1
Moment modification factor α_m-1

Results and report

The module reports: Section; Wheel load (with impact); Max moment (envelope); Max reaction / shear; Lateral surge / Mly; φMsx (section); φMsy (top flange); φVv.

It checks: Vertical bending (member, lateral-torsional buckling); Combined vertical + surge (top flange); Web shear.

Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.

Example with the default inputs

Crane Beam with its default inputs for the Australia and New Zealand code system. The main inputs:

InputValue
Section typeUB
Section610UB125
Runway span L6 m
Max static wheel load80 kN
Wheels on span2
Wheel spacing3 m
Impact factor1.1
Lateral surge10 %

Headline results:

ResultValue
Section610UB125 (UB)
Wheel load (with impact)88 kN
Max moment (envelope)148 kNm
Max reaction / shear132 kN
Lateral surge / Mly16 / 24 kN · kNm
φMbx (l_e 8.40 m)343 kNm

Governing check: Combined vertical + surge (top flange) (AS 4100 §5.2, §5.6), M*/φMbx + M*_ly/φMsy,flange against ≤ 1.0 (φMsy,flange 64.8 kNm), utilisation 0.80, passes.

Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.

Design codes

Crane Beam works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.

RegionStandard and edition
Australia and New ZealandAS 4100:2020, AS 1418.18
United StatesANSI/AISC 360-22, AISC DG 7, ASCE/SEI 7-22
CanadaCSA S16-19, NBC 2020
EuropeEN 1993-1-1:2005+A1:2014, EN 1993-6:2007, EN 1991-3:2006, EN 1993-1-9:2005

Use it in full during the 7-day trial of the Professional plan. Paid plans give access to the module packs. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.

Related modules

  • Beam-Column
    Steel member under combined axial compression and bending to AS 4100 §8
  • Compression Strut
    Axially-loaded steel member (strut / column) to AS 4100
  • Floor Beam
    Simply-supported steel floor beam to AS 4100
  • Load Stiffener
    Load-bearing web stiffener to AS 4100 §5.14
  • Mullion
    Steel wall mullion / wind post to AS 4100
  • PFC & Plate
    Built-up beam from a PFC (parallel-flange channel) with a welded plate
  • Portal Frame
    Single-bay portal frame to AS 4100
  • Propped Beam
    Steel propped cantilever to AS 4100

All steel design modules

Open Crane Beam with a free account