TensorNodeStart free trial
Home / Products / Steel design / PFC & Plate

PFC & Plate design check for AS 4100, AISC 360, CSA S16 and Eurocode 3

Built-up beam from a PFC (parallel-flange channel) with a welded plate.

Create a free account to use it

7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.

What it checks

The combined section properties (about the composite neutral axis) and the section moment and shear capacities to AS 4100.

Inputs

PFC & Plate takes 7 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.

InputUnitDefault
PFC
PFC section Options: 200PFC22.9; 250PFC35.5; 300PFC40.1; 380PFC55.2.-250PFC35.5
Plate
Plate width bpmm200
Plate thickness tpmm12
Plate position Options: Top flange; Bottom flange.-Top flange
Material
Yield fyMPa300
Actions
Design moment M*kNm60
Design shear V*kN80

Results and report

The module reports: Combined area A; Second moment I; Min section modulus; Moment capacity φMs; Shear capacity φVv.

It checks: Section moment capacity; Shear capacity (web).

Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.

Example with the default inputs

PFC & Plate with its default inputs for the Australia and New Zealand code system. The main inputs:

InputValue
PFC section250PFC35.5
Plate width bp200 mm
Plate thickness tp12 mm
Plate positionTop flange
Yield fy300 MPa
Design moment M*60 kNm
Design shear V*80 kN

Headline results:

ResultValue
Combined area A6920 mm²
Second moment I72.0 ×10⁶ mm⁴
Min section modulus423 (×1.17 vs PFC) ×10³ mm³
Moment capacity φMs114.1 kNm
Shear capacity φVv324 kN

Governing check: Section moment capacity (AS 4100 §5.2), M* 60.0 kNm against φMs 114.1 kNm, utilisation 0.53, passes.

Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.

Design codes

PFC & Plate works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.

RegionStandard and edition
Australia and New ZealandAS 4100:2020
United StatesANSI/AISC 360-22
CanadaCSA S16-19
EuropeEN 1993-1-1:2005+A1:2014, EN 1993-1-8:2005

Use it in full during the 7-day trial of the Professional plan. Paid plans give access to the module packs. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.

Related modules

All steel design modules

Open PFC & Plate with a free account

7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.