Factored UDL and midspan point load, section and member (lateral-torsional) moment, shear, and the floor deflection limits (live ≤ span/360, total ≤ span/250).

Inputs

Floor Beam takes 9 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.

InputUnitDefault
Section
Section type Options: UB; UC; PFC; UBP.-UB
Section-410UB53.7
Geometry
Span Lm7
Lateral restraint Options: Full (slab/deck); At supports only; Custom Le.-Full (slab/deck)
Loads
Dead UDL GkN/m8
Live UDL QkN/m10
Midspan dead pointkN0
Midspan live pointkN0
Moment modification αm-1.13

Results and report

The module reports: Section; Factored UDL w*; Design moment M*; φMbx (member); φVv; Live deflection δQ; Total deflection δ.

It checks: Section moment; Member moment (LTB); Live deflection; Total deflection.

Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.

Example with the default inputs

Floor Beam with its default inputs for the Australia and New Zealand code system. The main inputs:

InputValue
Section typeUB
Section410UB53.7
Span L7 m
Lateral restraintFull (slab/deck)
Dead UDL G8 kN/m
Live UDL Q10 kN/m
Midspan dead point0 kN
Midspan live point0 kN

Headline results:

ResultValue
Section410UB53.7 (UB)
Factored UDL w*24.6 kN/m
Design moment M*150.7 kNm
φMbx (member)305.3 kNm
φVv528.7 kN
Live deflection δQ8.3 (limit 19.4) mm

Governing check: Total deflection (AS 1170.0 (span/250)), δ 15.0 mm against L/250 28.0 mm, utilisation 0.53, passes.

Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.

Design codes

Floor Beam works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.

RegionStandard and edition
Australia and New ZealandAS 4100:2020
United StatesANSI/AISC 360-22
CanadaCSA S16-19
EuropeEN 1993-1-1:2005+A1:2014, EN 1990:2002+A1:2005

This module is one of the 21 basic calculators of the Free plan (one code system, reports carry an Evaluation mark), and it opens fully during the 7-day trial. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.

Related modules

  • Beam-Column
    Steel member under combined axial compression and bending to AS 4100 §8
  • Compression Strut
    Axially-loaded steel member (strut / column) to AS 4100
  • Crane Beam
    Overhead-crane runway beam
  • Load Stiffener
    Load-bearing web stiffener to AS 4100 §5.14
  • Mullion
    Steel wall mullion / wind post to AS 4100
  • PFC & Plate
    Built-up beam from a PFC (parallel-flange channel) with a welded plate
  • Portal Frame
    Single-bay portal frame to AS 4100
  • Propped Beam
    Steel propped cantilever to AS 4100

All steel design modules

Open Floor Beam with a free account

7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.