Floor Beam design check for AS 4100, AISC 360, CSA S16 and Eurocode 3
Simply-supported steel floor beam to AS 4100.
Create a free account to use it
7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.
What it checks
Factored UDL and midspan point load, section and member (lateral-torsional) moment, shear, and the floor deflection limits (live ≤ span/360, total ≤ span/250).
Inputs
Floor Beam takes 9 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.
| Input | Unit | Default |
|---|---|---|
| Section | ||
| Section type Options: UB; UC; PFC; UBP. | - | UB |
| Section | - | 410UB53.7 |
| Geometry | ||
| Span L | m | 7 |
| Lateral restraint Options: Full (slab/deck); At supports only; Custom Le. | - | Full (slab/deck) |
| Loads | ||
| Dead UDL G | kN/m | 8 |
| Live UDL Q | kN/m | 10 |
| Midspan dead point | kN | 0 |
| Midspan live point | kN | 0 |
| Moment modification αm | - | 1.13 |
Results and report
The module reports: Section; Factored UDL w*; Design moment M*; φMbx (member); φVv; Live deflection δQ; Total deflection δ.
It checks: Section moment; Member moment (LTB); Live deflection; Total deflection.
Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.
Example with the default inputs
Floor Beam with its default inputs for the Australia and New Zealand code system. The main inputs:
| Input | Value |
|---|---|
| Section type | UB |
| Section | 410UB53.7 |
| Span L | 7 m |
| Lateral restraint | Full (slab/deck) |
| Dead UDL G | 8 kN/m |
| Live UDL Q | 10 kN/m |
| Midspan dead point | 0 kN |
| Midspan live point | 0 kN |
Headline results:
| Result | Value |
|---|---|
| Section | 410UB53.7 (UB) |
| Factored UDL w* | 24.6 kN/m |
| Design moment M* | 150.7 kNm |
| φMbx (member) | 305.3 kNm |
| φVv | 528.7 kN |
| Live deflection δQ | 8.3 (limit 19.4) mm |
Governing check: Total deflection (AS 1170.0 (span/250)), δ 15.0 mm against L/250 28.0 mm, utilisation 0.53, passes.
Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.
Design codes
Floor Beam works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.
| Region | Standard and edition |
|---|---|
| Australia and New Zealand | AS 4100:2020 |
| United States | ANSI/AISC 360-22 |
| Canada | CSA S16-19 |
| Europe | EN 1993-1-1:2005+A1:2014, EN 1990:2002+A1:2005 |
This module is one of the 21 basic calculators of the Free plan (one code system, reports carry an Evaluation mark), and it opens fully during the 7-day trial. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.
Related modules
- Beam-Column
Steel member under combined axial compression and bending to AS 4100 §8 - Compression Strut
Axially-loaded steel member (strut / column) to AS 4100 - Crane Beam
Overhead-crane runway beam - Load Stiffener
Load-bearing web stiffener to AS 4100 §5.14 - Mullion
Steel wall mullion / wind post to AS 4100 - PFC & Plate
Built-up beam from a PFC (parallel-flange channel) with a welded plate - Portal Frame
Single-bay portal frame to AS 4100 - Propped Beam
Steel propped cantilever to AS 4100
Open Floor Beam with a free account
7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.