Portal Frame design check for AS 4100, AISC 360, CSA S16 and Eurocode 3
Single-bay portal frame to AS 4100.
Create a free account to use it
7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.
What it checks
The gravity and wind load cases give the knee and apex moments; the rafter and column (as beam-columns) are checked against their member moment capacities at the critical knee.
Inputs
Portal Frame takes 8 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.
| Input | Unit | Default |
|---|---|---|
| Frame | ||
| Frame span | m | 18 |
| Eaves height | m | 6 |
| Loads | ||
| Gravity load w | kN/m | 8 |
| Wind load | kN/m | 4 |
| Members | ||
| Column section type Options: UB; UC; PFC; RHS; SHS. | - | UB |
| Column section | - | 460UB74.6 |
| Rafter section type Options: UB; UC; PFC; RHS; SHS. | - | UB |
| Rafter section | - | 460UB74.6 |
Results and report
The module reports: Gravity moment; Wind moment; Knee moment (design); Column capacity φMbx; Rafter capacity φMbx.
It checks: Column (knee moment); Rafter (knee moment).
Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.
Example with the default inputs
Portal Frame with its default inputs for the Australia and New Zealand code system. The main inputs:
| Input | Value |
|---|---|
| Frame span | 18 m |
| Eaves height | 6 m |
| Gravity load w | 8 kN/m |
| Wind load | 4 kN/m |
| Column section type | UB |
| Column section | 460UB74.6 |
| Rafter section type | UB |
| Rafter section | 460UB74.6 |
Headline results:
| Result | Value |
|---|---|
| Gravity moment | 177 kNm |
| Wind moment | 38 kNm |
| Knee moment (design) | 214 kNm |
| Column capacity φMbx | 339 kNm |
| Rafter capacity φMbx | 339 kNm |
Governing check: Column (knee moment) (AS 4100 §5/§8), M* 214 kNm against φMbx 339 kNm, utilisation 0.63, passes.
Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.
Design codes
Portal Frame works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.
| Region | Standard and edition |
|---|---|
| Australia and New Zealand | AS 4100:2020 |
| United States | ANSI/AISC 360-22 |
| Canada | CSA S16-19 |
| Europe | EN 1993-1-1:2005+A1:2014, EN 1990:2002+A1:2005 |
Use it in full during the 7-day trial of the Professional plan. Paid plans give access to the module packs. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.
Related modules
- Beam-Column
Steel member under combined axial compression and bending to AS 4100 §8 - Compression Strut
Axially-loaded steel member (strut / column) to AS 4100 - Crane Beam
Overhead-crane runway beam - Floor Beam
Simply-supported steel floor beam to AS 4100 - Load Stiffener
Load-bearing web stiffener to AS 4100 §5.14 - Mullion
Steel wall mullion / wind post to AS 4100 - PFC & Plate
Built-up beam from a PFC (parallel-flange channel) with a welded plate - Propped Beam
Steel propped cantilever to AS 4100
Open Portal Frame with a free account