Steel Column design check for AS 4100, AISC 360, CSA S16 and Eurocode 3
Axially-loaded steel column to AS 4100 §6.
Create a free account to use it
7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.
What it checks
Section capacity (yield), member capacity (flexural buckling) with user-selected end fixity per axis (Le = ke·L), and the slenderness limit.
Inputs
Steel Column takes 8 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.
| Input | Unit | Default |
|---|---|---|
| Section | ||
| Section type Options: UC; UB; SHS; RHS; CHS; PFC. | - | UC |
| Section | - | 250UC72.9 |
| Geometry | ||
| Length about X | m | 4 |
| End fixity X (ke) Options: Pinned-Pinned (1.0); Fixed-Pinned (0.85); Fixed-Fixed (0.70); Fixed-Free (2.2); Braced sway (1.2); Sway (2.0). | - | Pinned-Pinned (1.0) |
| Length about Y | m | 4 |
| End fixity Y (ke) Options: Pinned-Pinned (1.0); Fixed-Pinned (0.85); Fixed-Fixed (0.70); Fixed-Free (2.2); Braced sway (1.2); Sway (2.0). | - | Pinned-Pinned (1.0) |
| Member constant αb Options: From the section type (Table 6.3.3); −1.0; −0.5; 0 (hot-rolled); 0.5; 1.0. | - | From the section type (Table 6.3.3) |
| Actions | ||
| Axial compression N* | kN | 1500 |
Results and report
The module reports: Section; Section capacity φNs; Effective length Le (x/y); λn (x / y); αc (governing); Member capacity φNc.
It checks: Section capacity (yield); Member capacity (buckling); Slenderness limit.
Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.
Example with the default inputs
Steel Column with its default inputs for the Australia and New Zealand code system. The main inputs:
| Input | Value |
|---|---|
| Section type | UC |
| Section | 250UC72.9 |
| Length about X | 4 m |
| End fixity X (ke) | Pinned-Pinned (1.0) |
| Length about Y | 4 m |
| End fixity Y (ke) | Pinned-Pinned (1.0) |
| Member constant αb | From the section type (Table 6.3.3) |
| Axial compression N* | 1500 kN |
Headline results:
| Result | Value |
|---|---|
| Section | 250UC72.9 (UC) |
| Section capacity φNs | 2516 kN |
| Effective length Le (x/y) | 4.00 / 4.00 (ke 1.00/1.00) m |
| λn (x / y) | 39 / 68 |
| αc (governing) | 0.761 |
| Member capacity φNc | 1916 kN |
Governing check: Member capacity (buckling) (AS 4100 §6.3), N* 1500 kN against φNc 1916 kN (αc 0.76), utilisation 0.78, passes.
Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.
Design codes
Steel Column works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.
| Region | Standard and edition |
|---|---|
| Australia and New Zealand | AS 4100:2020 |
| United States | ANSI/AISC 360-22 |
| Canada | CSA S16-19 |
| Europe | EN 1993-1-1:2005+A1:2014, EN 1990:2002+A1:2005 |
This module is one of the 21 basic calculators of the Free plan (one code system, reports carry an Evaluation mark), and it opens fully during the 7-day trial. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.
Related modules
- Beam-Column
Steel member under combined axial compression and bending to AS 4100 §8 - Compression Strut
Axially-loaded steel member (strut / column) to AS 4100 - Crane Beam
Overhead-crane runway beam - Floor Beam
Simply-supported steel floor beam to AS 4100 - Load Stiffener
Load-bearing web stiffener to AS 4100 §5.14 - Mullion
Steel wall mullion / wind post to AS 4100 - PFC & Plate
Built-up beam from a PFC (parallel-flange channel) with a welded plate - Portal Frame
Single-bay portal frame to AS 4100
Open Steel Column with a free account
7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.