T / Angle Lintel design check for AS 4100, AISC 360, CSA S16 and Eurocode 3
Steel lintel (angle, PFC or flat) over a masonry opening.
Create a free account to use it
7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.
What it checks
Masonry arching (triangular) load to AS 3700, bending and deflection to AS 4100, and support bearing.
Inputs
T / Angle Lintel takes 11 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.
| Input | Unit | Default |
|---|---|---|
| Section | ||
| Section type Options: Equal angle; Unequal angle; PFC; UB; UC. | - | Unequal angle |
| Section | - | 150 x 100 x 12 UA |
| Geometry | ||
| Clear opening span | m | 2.4 |
| Masonry | ||
| Wall thickness | mm | 110 |
| Wall height above lintel | m | 1.2 |
| Masonry density | kg/m³ | 1900 |
| Deflection limit Options: AS 3700 4.13: span/360, not over 10 mm; AS 4100 Table B1: span/500 (provision made to minimise the effect of movement); AS 4100 Table B1: span/1000 (no such provision). | - | AS 3700 4.13: span/360, not over 10 mm |
| Arching angle Options: 45°; 60°. | - | 60° |
| Loads | ||
| Superimposed UDL (floor/roof) | kN/m | 0 |
| Dead load factor | - | 1.2 |
| Masonry bearing strength | MPa | 5 |
Results and report
The module reports: Section; Arching apex height; Masonry load (triangle); Design moment M*; φMb; Service deflection δ; Required bearing length.
It checks: Deflection (service); Bearing length.
Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.
Example with the default inputs
T / Angle Lintel with its default inputs for the Australia and New Zealand code system. The main inputs:
| Input | Value |
|---|---|
| Section type | Unequal angle |
| Section | 150 x 100 x 12 UA |
| Clear opening span | 2.4 m |
| Wall thickness | 110 mm |
| Wall height above lintel | 1.2 m |
| Masonry density | 1900 kg/m³ |
| Deflection limit | AS 3700 4.13: span/360, not over 10 mm |
| Arching angle | 60° |
Headline results:
| Result | Value |
|---|---|
| Section | 150 x 100 x 12 UA (UEA) |
| Arching apex height | 2078 mm |
| Masonry load (triangle) | 4.2 kN |
| Design moment M* | 2.1 kNm |
| φMb | 17.6 kNm |
| Service deflection δ | 0.8 (limit 6.7) mm |
Governing check: Deflection (service) (AS 3700 §4.13), δ 0.8 mm against min(L/360,10) 6.7 mm, utilisation 0.12, passes.
Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.
Design codes
T / Angle Lintel works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.
| Region | Standard and edition |
|---|---|
| Australia and New Zealand | AS 4100:2020, AS 3700:2018 |
| United States | ANSI/AISC 360-22 |
| Canada | CSA S16-19 |
| Europe | EN 1993-1-1:2005+A1:2014, EN 1996-1-1:2005+A1:2012 |
Use it in full during the 7-day trial of the Professional plan. Paid plans give access to the module packs. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.
Related modules
- Beam-Column
Steel member under combined axial compression and bending to AS 4100 §8 - Compression Strut
Axially-loaded steel member (strut / column) to AS 4100 - Crane Beam
Overhead-crane runway beam - Floor Beam
Simply-supported steel floor beam to AS 4100 - Load Stiffener
Load-bearing web stiffener to AS 4100 §5.14 - Mullion
Steel wall mullion / wind post to AS 4100 - PFC & Plate
Built-up beam from a PFC (parallel-flange channel) with a welded plate - Portal Frame
Single-bay portal frame to AS 4100
Open T / Angle Lintel with a free account