Mander confined concrete in fibre sections
Concrete inside closed ties is stronger and far more ductile than the cover outside them. TensorNode models both with the Mander, Priestley and Park (1988) curve, the default concrete law of its fibre sections, and uses it for moment-curvature, section stress fields and the fibre hinges of the pushover and nonlinear analyses.

The stress-strain curve
With x = εc/εcc, the stress follows one smooth curve to the peak and beyond:
For unconfined concrete f'cc = f'co and εcc = εco (default 0.002). Beyond 2εcc the unconfined cover falls linearly to zero at the spalling strain. In tension the concrete is linear up to ft = 0.6√f'c and carries nothing after cracking.
Confinement from the ties
For the core inside the tie centreline, the confinement effectiveness of rectangular hoops and the effective lateral stress are
The lateral stress is taken in the weaker of the two directions, a conservative simplification of the biaxial chart. The ultimate strain of the core is the energy-balance estimate of Priestley, Seible and Calvi (1996), shown as indicative:
Moment-curvature from the fibres
The section is divided into fibres, each following the curve of its material. For a chosen axial force the curvature is increased step by step and the moment is found from equilibrium of the fibre stresses:
The curve marks cracking, first yield, cover spalling, crushing, the ultimate concrete strain, the compression limit of the bars and bar fracture. A bilinear idealisation gives the first yield moment, the nominal moment, the yield and ultimate curvatures and the curvature ductility.
Where the model is used
- The section designer: moment-curvature and interaction diagrams of drawn sections.
- Fibre hinges in the nonlinear static and pushover analyses, with the section's own materials.
- The section stress field of the concrete design modules: beams, columns, slab strips and walls, drawn over the cross-section and along the member.
- Reinforcement follows the Mander (1984) strain-hardening curve after the yield plateau, with fsu/fy from the product standard minimum, or elastic-plastic with 1 % hardening.
What it is and what it is not
The fibre field uses nominal strengths with no partial or resistance factors: it shows the expected behaviour of the section, not its design capacity, which the code check of the module gives. It is a beam-theory analysis, so shear lag, local buckling, bond slip and bar buckling are outside it.
Related modules
- Column Interaction
Rectangular reinforced-concrete column to AS 3600 §10 - Column Biaxial
RC column under axial load with biaxial bending to AS 3600 §10.6.3, the P-M interaction is built by strain compatibility about each axis, with reinforcement placed on all four faces (top/bottom bars resist X-axis bending, side bars resist Y-axis bending, both - Flexure Member
Rectangular, T- and L-beam flexure to AS 3600 - Concrete Wall
RC wall in compression by the AS 3600 §11.5.3 simplified method