TensorNodeStart free trial
Home / Products / Masonry design / Masonry Pier

Masonry Pier design check for AS 3700, TMS 402, CSA S304 and Eurocode 6

Masonry pier in compression to AS 3700.

Create a free account to use it

7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.

What it checks

The same §7.3 compression model applied to an isolated pier (engaged or freestanding) carrying a concentrated load, with the slenderness reduction.

Inputs

Masonry Pier takes 7 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.

InputUnitDefault
Pier
Pier length bmm350
Pier thickness tmm230
Height Hm3
Restraint Options: Top & bottom (av 1.0); One end (av 1.5); Cantilever (av 2.5).-One end (av 1.5)
Material
Unit strength f'ucMPa15
Mortar factor km-1.4
Actions
Axial load N*kN140

Results and report

The module reports: Bedded area Ab; Char. strength f'm; Slenderness Sr; Reduction factor k; Capacity φNc.

It checks: Compression capacity; Slenderness Sr.

Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.

Example with the default inputs

Masonry Pier with its default inputs for the Australia and New Zealand code system. The main inputs:

InputValue
Pier length b350 mm
Pier thickness t230 mm
Height H3 m
RestraintOne end (av 1.5)
Unit strength f'uc15 MPa
Mortar factor km1.4
Axial load N*140 kN

Headline results:

ResultValue
Bedded area Ab80500 mm²
Char. strength f'm5.42 MPa
Slenderness Sr19.6 (≤ 36)
Reduction factor k0.48
Capacity φNc156.7 kN

Governing check: Compression capacity (AS 3700 §7.3.4), N* 140 kN against φNc 156.7 kN, utilisation 0.89, passes.

Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.

Design codes

Masonry Pier works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.

RegionStandard and edition
Australia and New ZealandAS 3700:2018
United StatesTMS 402-22
CanadaCSA S304-14
EuropeEN 1996-1-1:2005+A1:2012

Use it in full during the 7-day trial of the Professional plan. Paid plans give access to the module packs. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.

Related modules

All masonry design modules

Open Masonry Pier with a free account

7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.