Masonry Pier design check for AS 3700, TMS 402, CSA S304 and Eurocode 6
Masonry pier in compression to AS 3700.
Create a free account to use it
7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.
What it checks
The same §7.3 compression model applied to an isolated pier (engaged or freestanding) carrying a concentrated load, with the slenderness reduction.
Inputs
Masonry Pier takes 7 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.
| Input | Unit | Default |
|---|---|---|
| Pier | ||
| Pier length b | mm | 350 |
| Pier thickness t | mm | 230 |
| Height H | m | 3 |
| Restraint Options: Top & bottom (av 1.0); One end (av 1.5); Cantilever (av 2.5). | - | One end (av 1.5) |
| Material | ||
| Unit strength f'uc | MPa | 15 |
| Mortar factor km | - | 1.4 |
| Actions | ||
| Axial load N* | kN | 140 |
Results and report
The module reports: Bedded area Ab; Char. strength f'm; Slenderness Sr; Reduction factor k; Capacity φNc.
It checks: Compression capacity; Slenderness Sr.
Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.
Example with the default inputs
Masonry Pier with its default inputs for the Australia and New Zealand code system. The main inputs:
| Input | Value |
|---|---|
| Pier length b | 350 mm |
| Pier thickness t | 230 mm |
| Height H | 3 m |
| Restraint | One end (av 1.5) |
| Unit strength f'uc | 15 MPa |
| Mortar factor km | 1.4 |
| Axial load N* | 140 kN |
Headline results:
| Result | Value |
|---|---|
| Bedded area Ab | 80500 mm² |
| Char. strength f'm | 5.42 MPa |
| Slenderness Sr | 19.6 (≤ 36) |
| Reduction factor k | 0.48 |
| Capacity φNc | 156.7 kN |
Governing check: Compression capacity (AS 3700 §7.3.4), N* 140 kN against φNc 156.7 kN, utilisation 0.89, passes.
Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.
Design codes
Masonry Pier works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.
| Region | Standard and edition |
|---|---|
| Australia and New Zealand | AS 3700:2018 |
| United States | TMS 402-22 |
| Canada | CSA S304-14 |
| Europe | EN 1996-1-1:2005+A1:2012 |
Use it in full during the 7-day trial of the Professional plan. Paid plans give access to the module packs. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.
Related modules
- Bondbeam
Reinforced masonry bond beam / lintel to AS 3700 - Masonry Member
Unreinforced masonry wall/member in vertical compression to AS 3700 - Sleeper Wall
Sleeper wall - T / Angle Lintel
Steel lintel (angle, PFC or flat) over a masonry opening
Open Masonry Pier with a free account