Masonry Member design check for AS 3700, TMS 402, CSA S304 and Eurocode 6
Unreinforced masonry wall/member in vertical compression to AS 3700.
Create a free account to use it
7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.
What it checks
The characteristic compressive strength from the unit strength and mortar factor, the slenderness reduction, and the design compression capacity.
Inputs
Masonry Member takes 7 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.
| Input | Unit | Default |
|---|---|---|
| Wall | ||
| Length b | mm | 230 |
| Thickness t | mm | 190 |
| Height H | m | 2.7 |
| Restraint Options: Top & bottom (av 1.0); One end (av 1.5); Cantilever (av 2.5). | - | Top & bottom (av 1.0) |
| Material | ||
| Unit strength f'uc | MPa | 15 |
| Mortar factor km | - | 1.4 |
| Actions | ||
| Axial load N* | kN | 40 |
Results and report
The module reports: Bedded area Ab; Char. strength f'm; Slenderness Sr; Reduction factor k; Capacity φNc.
It checks: Compression capacity; Slenderness Sr.
Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.
Example with the default inputs
Masonry Member with its default inputs for the Australia and New Zealand code system. The main inputs:
| Input | Value |
|---|---|
| Length b | 230 mm |
| Thickness t | 190 mm |
| Height H | 2.7 m |
| Restraint | Top & bottom (av 1.0) |
| Unit strength f'uc | 15 MPa |
| Mortar factor km | 1.4 |
| Axial load N* | 40 kN |
Headline results:
| Result | Value |
|---|---|
| Bedded area Ab | 43700 mm² |
| Char. strength f'm | 5.42 MPa |
| Slenderness Sr | 14.2 (≤ 36) |
| Reduction factor k | 0.64 |
| Capacity φNc | 114.4 kN |
Governing check: Slenderness Sr (AS 3700 §7.3.4.3), 14.2 against ≤ 36, utilisation 0.39, passes.
Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.
Design codes
Masonry Member works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.
| Region | Standard and edition |
|---|---|
| Australia and New Zealand | AS 3700:2018 |
| United States | TMS 402-22 |
| Canada | CSA S304-14 |
| Europe | EN 1996-1-1:2005+A1:2012 |
Use it in full during the 7-day trial of the Professional plan. Paid plans give access to the module packs. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.
Related modules
- Bondbeam
Reinforced masonry bond beam / lintel to AS 3700 - Masonry Pier
Masonry pier in compression to AS 3700 - Sleeper Wall
Sleeper wall - T / Angle Lintel
Steel lintel (angle, PFC or flat) over a masonry opening
Open Masonry Member with a free account
7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.