TensorNodeStart free trial

Bondbeam design check for AS 3700, TMS 402, CSA S304 and Eurocode 6

Reinforced masonry bond beam / lintel to AS 3700.

Create a free account to use it

7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.

What it checks

The span moment and shear from the applied load, the reinforced flexural capacity, the masonry shear capacity and the minimum reinforcement.

Inputs

Bondbeam takes 8 inputs for the Australia and New Zealand code system, with the defaults below. Lengths are in m, forces in kN and stresses in MPa unless the unit column says otherwise.

InputUnitDefault
Geometry
Clear spanm2
Beam depthmm200
Width bwmm190
Covermm30
Reinforcement
Reinforcement Options: 1-N12 (113); 2-N12 (226); 2-N16 (400); 2-N20 (620).-2-N12 (226)
Material
Steel fsyMPa500
Masonry f'mMPa12
Actions
Design load wkN/m10

Results and report

The module reports: Effective depth d; Moment / shear; Flexural capacity φMu; Shear capacity Vu; Min reinforcement.

It checks: Flexural capacity; Shear capacity; Minimum reinforcement.

Each module produces a report: numbered working, formulas with substituted values, tables and diagrams, ready to attach to a calculation package. The report carries a verification code that confirms it was made by TensorNode and has not been changed.

Example with the default inputs

Bondbeam with its default inputs for the Australia and New Zealand code system. The main inputs:

InputValue
Clear span2 m
Beam depth200 mm
Width bw190 mm
Cover30 mm
Reinforcement2-N12 (226)
Steel fsy500 MPa
Masonry f'm12 MPa
Design load w10 kN/m

Headline results:

ResultValue
Effective depth d164 mm
Moment / shear5.0 / 10.0 kNm, kN
Flexural capacity φMu12.0 kNm
Shear capacity Vu11.1 kN
Min reinforcement49 mm²

Governing check: Shear capacity (AS 3700 §8.8 (Eq. 8.8)), V* 10.0 kN against φVu 11.1 kN, utilisation 0.90, passes.

Computed by TensorNode with the default inputs shown; a qualified engineer checks every result.

Design codes

Bondbeam works to 4 code systems in Australia and New Zealand, United States, Canada and Europe. The standards and editions are listed below; clause numbers are cited in the report.

RegionStandard and edition
Australia and New ZealandAS 3700:2018
United StatesTMS 402-22
CanadaCSA S304-14
EuropeEN 1996-1-1:2005+A1:2012

Use it in full during the 7-day trial of the Professional plan. Paid plans give access to the module packs. TensorNode is a calculation aid. Every result must be checked and accepted by a qualified engineer, who remains responsible for the design. Read the scope and limits of this module before you rely on a result.

Related modules

All masonry design modules

Open Bondbeam with a free account

7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.