3D finite element analysis that hands every member to its design module
The FEA Tool does not hold its own member checks. After the analysis it sends each member, with its design actions, to the TensorNode design module that covers it, exactly as if you had filled in that module by hand, and collects the utilisation and the governing check.

Twelve analysis types in one model
Linear static, P-Delta, buckling, nonlinear static, pushover, modal, Ritz vectors, response spectrum, equivalent lateral force, storey checks, linear time history and nonlinear time history. Frames, trusses, plates and shells share one model, and areas are meshed automatically and matched to the frames.
From analysis to design in one run
- Run the analysis with the strength combinations: linear static, or P-Delta for a sway-sensitive frame.
- Press Run design. Every member is matched to its module and designed for the envelope of the strength combinations.
- Read the batch design table: each member with its section, module, governing check, utilisation and status. The model view colours the members by utilisation.
- Fix what fails (a section, a restraint, a missing input), then analyse and design again until the sections in the analysis are the ones that pass.
- Open in module shows one member in its module with every input filled, to read or print the full calculation with its clauses.
How a member reaches its module
| Member | Module |
|---|---|
| Steel beam with major-axis bending (AS) | Steel Member, with the moment reproduced for a simply supported span |
| Steel member with bending, otherwise | Beam-Column |
| Steel member in compression only | Steel Column |
| Steel member in tension only | Tension Member |
| Concrete column | Column Interaction, with Beam Shear |
| Concrete beam | Flexure, with Beam Shear |
| Timber member | The timber member or column module of the code |
For an AS steel beam the FEA Tool sets the module's design load from the analysed moment, so the module reproduces that moment over the member length:
Only the analysed actions govern
A module that derives an action from its own inputs (the AS Steel Member derives V* = w*L/2 from w*) has that derived check set aside and replaced by a check of the analysed action against the same capacity. The member is designed for the forces of the model, not for the simplified load the module would assume on its own.
Related modules
- Steel Member
Hot-rolled steel member (UB / UC / PFC / TFB) to AS 4100 - Beam-Column
Steel member under combined axial compression and bending to AS 4100 §8 - Column Interaction
Rectangular reinforced-concrete column to AS 3600 §10 - Flexure Member
Rectangular, T- and L-beam flexure to AS 3600
More
Create a free account to use it
7 days of the Professional plan, no card. After the trial the account moves to the Free plan; nothing is charged automatically.